Triangle Tube PSRKIT15

PSRKIT15 Prestige Igniter with Gasket User Manual

Brand: Trijangolu Tube

Introduzzjoni

This manual provides essential information for the installation, operation, maintenance, and troubleshooting of the Triangle Tube PSRKIT15 Prestige Igniter with Gasket. This component is designed for use with Triangle Tube Prestige PS110, PS175, PS250, Solo 399, Solo 60, Solo 110, Solo 175, Solo 250, Solo 399, and Prestige Excellence 110 boilers.

The igniter is a critical part of the boiler's ignition system, responsible for initiating the combustion process. Proper installation and maintenance are crucial for safe and efficient boiler operation.

Informazzjoni dwar is-Sigurtà

Always prioritize safety when working with boiler systems. Installation and maintenance should only be performed by qualified and experienced technicians. Failure to follow safety guidelines can result in property damage, serious injury, or death.

Setup u Installazzjoni

The PSRKIT15 igniter is a direct replacement part. Follow the specific installation instructions provided in your boiler's service manual. The general steps for replacement are outlined below:

  1. Preparazzjoni: Ensure the boiler is powered off and the gas supply is closed. Allow the boiler to cool.
  2. Aċċess: Locate the igniter assembly within the boiler's combustion chamber. This may require removing access panels or other components.
  3. Skonnettja l-Igniter il-Qadim: Carefully disconnect the electrical wiring from the old igniter. Note the orientation and connection points.
  4. Neħħi l-Igniter il-Qadim: Unfasten any mounting screws or clips securing the old igniter. Gently remove it, ensuring the old gasket is also removed.
  5. Installa Gasket Ġdid: Place the new gasket included with the PSRKIT15 kit onto the mounting surface. Ensure it is properly seated and aligned.
  6. Installa Igniter Ġdid: Carefully insert the new PSRKIT15 igniter into its position, aligning it with the mounting holes. Secure it with the appropriate fasteners. Do not overtighten.
  7. Qabbad il-Wiring: Reconnect the electrical wiring to the new igniter, ensuring all connections are secure and correct.
  8. Erġa' arma: Replace any removed access panels or components.
  9. Test: Restore gas and electrical power to the boiler. Initiate a call for heat and observe the ignition sequence to confirm proper operation of the new igniter. Check for any gas leaks.
Triangle Tube PSRKIT15 Prestige Igniter with Gasket

Image: The Triangle Tube PSRKIT15 Prestige Igniter with Gasket. This image shows the igniter component, which consists of a ceramic body with two metal electrodes and a metal mounting bracket. A blue-grey gasket is visible attached to one end, ready for installation.

Prinċipji Operattivi

The PSRKIT15 igniter functions as a hot surface igniter (HSI). When the boiler control board calls for heat, an electrical current is sent to the igniter, causing its ceramic element to heat up rapidly to a very high temperature. This incandescent surface then ignites the gas-air mixture in the combustion chamber. Once ignition is confirmed by the flame sensor, the igniter typically de-energizes, and the flame is sustained by the continuous flow of gas.

This igniter is designed for intermittent pilot applications, meaning it only energizes when there is a call for heat, providing a safe and efficient ignition method.

Manutenzjoni

Regular inspection of the igniter is recommended as part of routine boiler maintenance, typically performed annually by a qualified technician.

Issolvi l-problemi

If your boiler is experiencing ignition problems, the igniter may be a contributing factor. Always consult a qualified technician for diagnosis and repair.

Sintomu Kawża Possibbli Azzjoni
Boiler does not ignite (no glow from igniter) No power to igniter, faulty igniter, control board issue, open limit switch. Check electrical connections. Test igniter for continuity/resistance (refer to boiler manual for specs). Inspect control board. Verify all safety switches are closed.
Igniter glows but no ignition (no flame) Insufficient gas pressure, faulty gas valve, igniter not hot enough, blocked burner, faulty flame sensor. Verify gas supply. Check gas valve operation. Inspect igniter for cracks/damage. Clean burner ports. Check flame sensor.
Tqabbid intermittenti Weak igniter, fluctuating gas pressure, dirty flame sensor, loose wiring. Inspect and test igniter. Check gas pressure. Clean flame sensor. Secure all electrical connections.

Always consult the comprehensive troubleshooting guide in your specific Triangle Tube boiler manual for detailed diagnostic procedures.

Speċifikazzjonijiet

Attribut Dettall
Numru tal-Mudell PSRKIT15
Komponenti Inklużi Igniter with Gasket
Kompatibilità Triangle Tube Prestige Solo 60, 110, 175, 250, 399 boilers; Prestige Excellence 110 boilers
Piż tal-oġġett Madwar 5-il uqija (0.14 kg)
Dimensjonijiet tal-Prodott Madwar 6 x 6 x 2 pulzieri (15.24 x 15.24 x 5.08 cm)
Numru tal-Parti PSRKIT15
UPC 645220463930

Garanzija u Appoġġ

For specific warranty information regarding the PSRKIT15 Prestige Igniter with Gasket, please refer to the documentation provided with your original boiler purchase or contact Triangle Tube directly. Warranty terms typically cover manufacturing defects.

For technical support, service, or to purchase genuine replacement parts, please contact an authorized Triangle Tube dealer or service provider. Always ensure that replacement parts are genuine to maintain boiler performance and safety.

Triangle Tube Official Websit: www.triangletube.com

Dokumenti Relatati - PSRKIT15

Preview Istruzzjonijiet għall-Installazzjoni tal-Kit tal-Ignizzjoni bi Spark tal-Bojler tat-Triangle Tube Prestige Solo/Excellence
Istruzzjonijiet dettaljati għall-installazzjoni għat-Triangle Tube Spark Ignition Kit (serje PARKIT) għall-bojlers tal-gass Prestige Solo PA u Prestige Excellence PA. Ikopri s-sostituzzjoni tal-komponenti, is-setup, il-konfigurazzjoni, u l-ittestjar tal-kombustjoni.
Preview Istruzzjonijiet għall-Installazzjoni u l-Manutenzjoni tal-Kit tad-Detector tas-CO tat-Triangle Tube Prestige
Gwida komprensiva għall-installazzjoni, it-tħaddim, u l-manutenzjoni tat-Triangle Tube Prestige Carbon Monoxide (CO) Detector Kit. Tkopri l-applikabbiltà, il-proċeduri ta' installazzjoni għal diversi mudelli ta' bojlers, dijagrammi tal-wajers, kontrolli funzjonali, is-soluzzjoni tal-problemi, u informazzjoni dwar is-sigurtà tal-utent.
Preview Istruzzjonijiet għall-Installazzjoni tal-Kit tal-Ignizzjoni bi Spark Prestige PT ta' Triangle Tube
Comprehensive installation instructions for the Triangle Tube Prestige PT Spark Ignition Kit, covering unit identification, kit contents, boiler modification, start-up procedures, and combustion testing for models PT 60-110-175-250-399 and PTE 110.
Preview Manwal tal-Installazzjoni u l-Manutenzjoni tal-Bojler tal-Ilma Triangle Tube Prestige Solo 110
Gwida komprensiva għall-installazzjoni, it-tħaddim, u l-manutenzjoni tat-Triangle Tube Prestige Solo 110 Water Boiler. Tkopri s-sigurtà, il-preinstallazzjoni, il-kombustjoni, il-pajpijiet, il-wajers, il-bidu, u l-proċeduri tal-manutenzjoni.
Preview Speċifikazzjonijiet tal-Bojler Ċertifikat ENERGY STAR tat-Triangle Tube Prestige SOLO 80
Speċifikazzjonijiet dettaljati għall-bojler Triangle Tube Prestige SOLO 80, prodott iċċertifikat ENERGY STAR. Jinkludi informazzjoni dwar l-ENERGY STAR ID, il-marka, il-mudell, it-tip ta' fjuwil, l-effiċjenza, u d-disponibbiltà fis-suq.
Preview Speċifikazzjonijiet tal-Bojler Ċertifikat ENERGY STAR tat-Triangle Tube Prestige SOLO 175
Speċifikazzjonijiet dettaljati għat-Triangle Tube Prestige SOLO 175, bojler iċċertifikat mill-ENERGY STAR. Jinkludi informazzjoni dwar it-tip ta' fjuwil, l-effiċjenza, u d-disponibbiltà fis-suq.