Tekmar 078

Tekmar 078 Universal Sensor with 15' Wire Instruction Manual

Model: 078 | Brand: Tekmar

Introduzzjoni

The Tekmar 078 Universal Sensor is designed for accurate temperature measurement in various applications. It features a robust, stiff jacketed cable for simplified installation into conduits or domestic hot water tank temperature wells. This versatile sensor can also be securely strapped to pipes to monitor supply or return temperatures.

Karatteristiċi Ewlenin

  • 10K Thermistor: Jipprovdi qari preċiż tat-temperatura.
  • Preċiżjoni Għolja: Achieves an accuracy of +/-0.2°C.
  • Kostruzzjoni Durabbli: Features a corrosion-resistant brass sleeve.
  • Rispons Mgħaġġel: Offers very fast temperature response for dynamic monitoring.
  • Installazzjoni faċli: Stiff jacketed cable facilitates straightforward wiring in conduit.
  • Ċertifikazzjonijiet: CSA and C US Approved for use in USA and Canada.

Setup u Installazzjoni

The Tekmar 078 Universal Sensor is designed for flexible installation. Always ensure power is disconnected before beginning any installation procedures.

Metodi ta 'installazzjoni:

  • Conduit Installation: The stiff jacketed cable allows for easy pulling through conduit. Ensure the sensor tip is positioned correctly for accurate readings.
  • Domestic Hot Water Tank Wells: Insert the sensor tip into the designated temperature well of the hot water tank.
  • Pipe Strapping: For measuring supply or return temperatures, securely strap the sensor to the pipe. Ensure good thermal contact between the sensor tip and the pipe surface.

Connect the sensor wires to the appropriate terminals on your control system as per the system's wiring diagram. The sensor is a 10K thermistor type.

Tekmar 078 Universal Sensor with 15-foot wire, coiled.
An image showing the Tekmar 078 Universal Sensor. It features a gray, stiff jacketed cable coiled, with a small brass-colored sensor tip visible at one end. The cable is approximately 15 feet long.

Prinċipji Operattivi

The Tekmar 078 operates as a 10K thermistor, which changes its electrical resistance in response to temperature variations. This change in resistance is then interpreted by a compatible control system to provide an accurate temperature reading. Its fast response time ensures that temperature fluctuations are detected promptly.

Manutenzjoni

The Tekmar 078 Universal Sensor requires minimal maintenance. Regular inspection is recommended to ensure optimal performance:

  • Spezzjoni Viżwali: Periodically check the cable and sensor tip for any signs of physical damage, wear, or corrosion. The brass sleeve is corrosion-resistant, but extreme conditions may still affect it over time.
  • Integrità tal-Konnessjoni: Ensure all electrical connections remain secure and free from moisture or debris.
  • Indafa: Keep the sensor tip clean from any buildup that might impede accurate temperature sensing.

Do not attempt to disassemble the sensor. If damage is observed, replace the unit.

Issolvi l-problemi

If the sensor is not providing expected readings or appears to be malfunctioning, consider the following:

  • Iċċekkja l-Konnessjonijiet: Verify that all wiring connections are correct and secure at both the sensor and the control system.
  • Tqegħid tas-Sensor: Ensure the sensor is properly positioned and has good thermal contact with the medium it is intended to measure. Incorrect placement can lead to inaccurate readings.
  • Integrità tal-Cable: Inspect the 15-foot cable for any cuts, pinches, or damage that could interrupt the signal.
  • Control System Compatibility: Confirm that the control system is compatible with a 10K thermistor type sensor.

If issues persist after checking these points, consult the control system's manual or contact Tekmar technical support.

Speċifikazzjonijiet

AttributDettall
BrandTekmar
Mudell078
Tip tas-Sensor10K Termistor
Eżattezza+/- 0.2 ° C
Tul tal-Cable15 pied
MaterjalBrass (corrosion-resistant sleeve)
Dimensjonijiet tal-oġġett (L x W x H)1 x 1 x 1 pulzieri (Dimensjonijiet tal-Prodott)
Piż tal-oġġett2.12 uqija
Tip ta 'ImmuntarFlange Mount (for sensor tip)
UPC782301923355
ĊertifikazzjonijietCSA and C US Approved

Garanzija u Appoġġ

For detailed warranty information regarding the Tekmar 078 Universal Sensor, please refer to the official documentation provided by Tekmar at the time of purchase or visit the manufacturer's websit.

For technical assistance, installation queries, or troubleshooting support, please contact Tekmar customer service directly. Contact information can typically be found on the product packaging or the official Tekmar websit.

Dokumenti Relatati - 078

Preview Installation and Operation Manual for tekmar Three Outdoor Sensor Module 081
This manual provides detailed installation and operation instructions for the tekmar Three Outdoor Sensor Module 081. It covers mounting, wiring, sensor testing, technical specifications, and warranty information for the module, which is designed to measure outdoor temperature using NTC thermistors.
Preview tekmar Universal Reset Control 363 User Brochure
Comprehensive guide to the tekmar Universal Reset Control 363, detailing its features, user interface, access levels, and menu options for optimizing hydronic heating systems, including integration with RTUs.
Preview Gwida għas-Soluzzjoni tal-Problemi għall-Modulu ta' Reset Universali tekmar 422
Gwida komprensiva għas-soluzzjoni tal-problemi għat-tekmar 422 Universal Reset Module, li tkopri kwistjonijiet komuni bħal skrins vojta, żbalji fis-sensuri, problemi fit-tqabbid tal-bojler, u kwistjonijiet ta' kontroll tat-taħlit. Tinkludi passi dettaljati u kontrolli għad-dijanjosi u r-riżoluzzjoni tal-problemi.
Preview Smart Steam Control 289 | tekmar Advanced Steam Boiler Management
The tekmar Smart Steam Control 289 is an advanced, connected system for managing multiple steam boilers. It offers remote access via the Nexa app, up to 20% energy savings, a 5-inch touchscreen, and compatibility with optional sensors, making it ideal for commercial HVAC applications.
Preview Gwida għas-Soluzzjoni tal-Problemi għall-Modulu ta' Reset Universali tekmar 423
Comprehensive troubleshooting guide for the tekmar 423 Universal Reset Module, covering sensor inputs, sensor checks, outdoor sensor notes, bypassing outdoor sensor, boiler firing issues, mixing control problems, floating action valve checks, variable speed pump operation, bus configuration, and DHW settings. Includes a detailed sensor resistance table.
Preview Manwal tal-Utent tat-Termostat WiFi tekmar 562
Manwal tal-utent għat-tekmar WiFi Thermostat 562, li jiddeskrivi l-karatteristiċi, is-setup u t-tħaddim tiegħu għal kontroll preċiż tat-temperatura tas-sistemi tat-tisħin u tat-tkessiħ, inkluż aċċess remot permezz ta' app mobbli u websit.