1. Introduzzjoni
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your Connecticut Electric EGS107501G2 30Amp 10 Circuit G2 Manual Transfer Switch. This device is designed to safely connect a portable generator to your home's electrical system during power outages, ensuring critical circuits remain operational.
The EGS107501G2 features a 30-amp, 10-circuit design, preventing power back-feeding into the utility line or generator. Its NEMA 3R rainproof enclosure allows for both indoor and outdoor installation.

Figure 1: Connecticut Electric EGS107501G2 Manual Transfer Switch
This image displays the Connecticut Electric EGS107501G2 Manual Transfer Switch. The gray metal enclosure is shown with its front door open, revealing ten circuit breakers inside. Each breaker has a switch labeled "LINE" and "GEN" for selecting the power source. Below the breakers, two analog watt meters are visible, labeled "A-E" and "F-J", indicating power consumption for different circuit groups. Wires are seen exiting the bottom right of the enclosure.
2. Informazzjoni Importanti dwar is-Sigurtà
WARNING: Risk of Electric Shock or Fire. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Always disconnect power at the main service panel before installing or servicing the transfer switch.
- Ensure the generator is properly grounded according to its manufacturer's instructions.
- Never operate the transfer switch with wet hands or while standing in water.
- Do not attempt to modify the transfer switch. Unauthorized modifications can lead to serious injury or damage and will void the warranty.
- This transfer switch is designed for use with emergency generators up to 30 amps with a NEMA L14-30 output.
- The double throw rocker switches are designed to prevent back-feeding. Always ensure switches are fully engaged in either the "LINE" or "GEN" position.
3. Kontenut tal-Pakkett
Iċċekkja li l-oġġetti kollha huma preżenti qabel tibda l-installazzjoni:
- Connecticut Electric EGS107501G2 Manual Transfer Switch
- Manwal ta' Installazzjoni u Tħaddim (dan id-dokument)
- Mounting hardware (may vary)
4. Setup u Installazzjoni
Installation of the EGS107501G2 Manual Transfer Switch requires electrical expertise. It is strongly recommended that a qualified electrician performs the installation to ensure safety and compliance with all applicable codes.
4.1. Ippjanar tal-Post tal-Installazzjoni
The transfer switch enclosure has a NEMA 3R rainproof rating, making it suitable for both indoor and outdoor installation. Choose a location that is:
- Close to your main service panel.
- Accessible for operation and maintenance.
- Protected from physical damage.
- Within reach of your portable generator's power cord (if using an outdoor inlet box).
4.2. Mounting the Transfer Switch
- Ensure the mounting surface is sturdy and capable of supporting the weight of the transfer switch.
- Use appropriate mounting hardware (not always included) to securely fasten the transfer switch to the wall or other suitable surface.
- Ensure the enclosure is level and plumb.
4.3. Konnessjonijiet tal-Wiring
All wiring must be performed with the main utility power disconnected.
- Connect the utility (LINE) input wires from your main service panel to the designated terminals within the transfer switch.
- Connect the generator (GEN) input wires from your generator inlet box to the designated terminals.
- Connect the output wires from the transfer switch to the selected circuits in your main service panel. The unit supports 10 circuits, including 240-volt circuits for applications like well pumps. If a 2-pole circuit is not needed, the tie bar can be removed to create two single-pole circuits.
- Ensure all connections are tight and secure. Follow the wiring diagram provided with the unit for specific terminal assignments.
- Properly ground the transfer switch enclosure.

Figure 2: Emergency Power System Diagram
This diagram illustrates a typical emergency power setup. A portable power generator is shown outside a house, connected to a rain-tight power inlet box. From there, wiring leads to an electrical junction box, then to the EmerGen Switch (manual transfer switch), which is connected to the home's loadcenter (main electrical panel). This setup ensures safe and managed power transfer during outages.
5. Istruzzjonijiet Operattivi
The Connecticut Electric EGS107501G2 operates in an ON-NONE-OFF mode, allowing you to safely switch between utility power and generator power for individual circuits.
5.1. Transferring to Generator Power (During an Outage)
- Turn off all connected appliances: Before starting your generator, turn off or unplug sensitive electronics and heavy-load appliances to prevent surge damage.
- Start the generator: Follow your generator manufacturer's instructions to start it. Allow it to warm up for a few minutes.
- Connect the generator: Plug your generator's power cord into the outdoor power inlet box.
- Switch circuits to GEN: Open the transfer switch door. For each circuit you wish to power with the generator, move its rocker switch from the "LINE" position (utility power) to the "GEN" position (generator power). Ensure each switch clicks firmly into place.
- Restore power to appliances: Once circuits are switched, you can gradually turn on your selected appliances. Avoid overloading the generator.
5.2. Transferring to Utility Power (When Utility Power is Restored)
- Turn off connected appliances: Turn off or unplug appliances connected to the circuits powered by the generator.
- Switch circuits to LINE: For each circuit currently on "GEN", move its rocker switch to the "LINE" position. Ensure each switch clicks firmly into place.
- Disconnect and shut down generator: Unplug the generator cord from the inlet box. Follow your generator manufacturer's instructions to shut down the generator.
- Restore power to appliances: Once all circuits are back on utility power, you can gradually turn on your appliances.
The built-in watt meters (A-E and F-J) provide an indication of the load on the respective circuit groups when operating on generator power. Monitor these to avoid overloading your generator.
6. Manutenzjoni
The Connecticut Electric EGS107501G2 Manual Transfer Switch is designed for minimal maintenance. However, periodic checks are recommended:
- Spezzjoni Annwali: Have a qualified electrician inspect the transfer switch and all connections annually to ensure they remain tight and free from corrosion or damage.
- Indafa: Keep the exterior of the enclosure clean and free from dust, dirt, and debris. Do not use abrasive cleaners or solvents.
- Kontroll Operattiv: Periodically test the transfer switch by simulating a power outage (if safe to do so and with proper precautions) to ensure all switches operate smoothly and circuits transfer correctly.
7 Issolvi l-problemi
If you experience issues with your transfer switch, consult the following table. For problems not listed or if solutions do not resolve the issue, contact a qualified electrician or Connecticut Electric customer support.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| No power to circuits when on "GEN" |
|
|
| No power to circuits when on "LINE" |
|
|
| Watt meters not displaying readings |
|
|
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | EGS107501G2 |
| Brand | Connecticut Elettriku |
| Klassifikazzjoni kurrenti | 30 Amps |
| Vol Operattivtage | 240 Volts |
| Numru ta' Ċirkwiti | 10 |
| Mod ta' Operazzjoni | ON-NONE-OFF |
| Klassifikazzjoni tal-Magħluq | NEMA 3R (Rainproof) |
| Dimensjonijiet tal-Prodott (L x W x H) | 10 x 5 x 13 pulzieri |
| Piż tal-oġġett | 21.6 Liri |
| Tip ta' Kuntatt | Normalment Magħluq |
| Tip ta' Konnettur | Din |
| Tip ta' Terminal | Invita |
| Tip ta 'Ċirkwit | Parallel |
| Tip ta' Attwatur | Push Button (for breakers) |
9. Garanzija u Appoġġ
For warranty information or technical support regarding your Connecticut Electric EGS107501G2 Manual Transfer Switch, please contact Connecticut Electric directly. Refer to the product packaging or the official Connecticut Electric webis-sit għad-dettalji ta' kuntatt l-aktar aġġornati.
Manifattur: Connecticut Elettriku