1. Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of the Eaton TR274W Combo Single-Pole Switch with Tamper Resistant Receptacle. This device combines a single-pole toggle switch and a 15-amp, 125-volt tamper-resistant duplex receptacle into a single unit, designed for residential and commercial applications. It features a neon pilot light that indicates when the switch is in the ON position.
2. Informazzjoni dwar is-Sigurtà
WARNING: Risk of electric shock. Improper installation can result in serious injury or death. Always turn off power at the circuit breaker or fuse box before installation or servicing. If you are unsure about any part of these instructions, consult a qualified electrician.
- This device is UL listed, ensuring compliance with safety standards.
- It-tamper-resistant shutters in the receptacle are designed to prevent the insertion of foreign objects, enhancing safety, especially for children.
- Kun żgur li l-konnessjonijiet kollha tal-wajers huma sikuri u jikkonformaw mal-kodiċijiet elettriċi lokali.
- Do not exceed the specified electrical ratings: 15 Amps, 120 Volts for the switch; 15 Amps, 125 Volts for the receptacle.
3. Karatteristiċi tal-prodott
- Integrated single-pole toggle switch and tamper-resistant 2-pole, 3-wire receptacle.
- Toggle switch rated for 15 Amps, 120 Volt.
- Tamper-resistant receptacle rated for 15 Amps, 125 Volt.
- UL listed tamper-resistant shutters for enhanced safety.
- Neon pilot light indicates when the switch is ON.
- Durable thermoplastic toggle, top, and back body construction.
- Ultrasonic welding and integrated strap design for superior ground integrity.
- Zinc-plated steel mounting strap for corrosion resistance.
- Terminal screws are backed out for easier wiring.
4. Konfigurazzjoni u Installazzjoni
Before beginning installation, ensure the power to the circuit is OFF at the service panel. Use a voltage tester biex tikkonferma li l-enerġija hija mitfija.
4.1 Dijagramma tal-Wajers ta' Fuqview
The Eaton TR274W is designed for various wiring configurations. The device typically has brass screws for hot (line/load), silver screws for neutral, and a green screw for ground. Terminal screws are pre-backed out for convenience.
Common Wiring Configuration (Switch Controls Receptacle):
- Connect the incoming hot (black) wire to one of the brass screws.
- Connect the outgoing hot (load) wire to the other brass screw.
- Connect the incoming neutral (white) wire to one of the silver screws.
- Connect the outgoing neutral (load) wire to the other silver screw.
- Connect the ground (bare copper or green) wire to the green grounding screw.
Independent Wiring Configuration (Switch and Receptacle operate independently):
For configurations where the switch controls a separate load and the receptacle is always hot, or if you want the neon pilot light to only illuminate when the switch is ON and controlling the receptacle, internal jumpers may need to be modified. Consult a qualified electrician or refer to specific wiring diagrams for advanced configurations. Some installations may require breaking a small metal tab between the hot terminals and adding a jumper wire to achieve desired functionality, such as having the neon light only illuminate when the switch is active and controlling the receptacle.
4.2 Passi ta' Installazzjoni
- Itfi l-Enerġija: Locate the circuit breaker or fuse controlling the outlet you are replacing and turn it OFF. Verify with a voltagtester.
- Neħħi l-Apparat il-Qadim: Carefully remove the existing wall plate and device from the electrical box. Disconnect the wires.
- Ipprepara Wajers: Strip approximately 1/2 inch of insulation from the ends of the wires if necessary.
- Qabbad Wajers: Follow the appropriate wiring diagram for your desired functionality. Securely connect the wires to the corresponding terminal screws on the TR274W device. Ensure no bare wire is exposed outside the terminals.
- Apparat tal-Immuntar: Gently fold the wires into the electrical box and secure the TR274W device to the box using the mounting screws provided.
- Installa Pjanċa tal-Ħajt: Attach the decorative wall plate (sold separately) over the device.
- Irrestawra l-Enerġija: Erġa’ ixgħel il-provvista tal-enerġija mis-circuit breaker jew mill-kaxxa tal-fjużijiet.
- Funzjonalità tat-Test: Test the switch and receptacle to ensure they operate correctly.

Figura 1: Quddiem view of the Eaton TR274W Combo Single-Pole Switch with Tamper Resistant Receptacle. Shows the toggle switch at the top, the neon pilot light below it, and the tamper-resistant receptacle at the bottom. The "TR" marking indicates tamper reżistenza.

Figura 2: Ġenb view of the Eaton TR274W Combo Switch and Receptacle. This image highlights the wiring terminals (brass, silver, and green ground screw) and the robust construction of the device.
5. Istruzzjonijiet Operattivi
5.1 Toggle Switch Operation
The toggle switch functions as a standard single-pole switch. Push the toggle up to turn the connected load ON, and push it down to turn the load OFF. When the switch is in the ON position, the integrated neon pilot light will illuminate, providing a visual indication of its status.
5.2 Tamper Resistant Receptacle Operation
It-tamper-resistant receptacle features internal shutters that block access to the contacts unless a two-pronged or three-pronged plug is inserted simultaneously. This design helps prevent accidental insertion of foreign objects. To use the receptacle, firmly insert a standard electrical plug into the openings. You may feel slight resistance due to the shutters; this is normal. Ensure the plug is fully seated for proper contact.
6. Manutenzjoni
- Tindif: To clean the device, ensure power is OFF at the circuit breaker. Wipe the surface with a soft, damp drapp. Tużax tindif jew solventi li joborxu.
- Spezzjoni: Periodically inspect the device for any signs of damage, loose connections, or discoloration. If any issues are observed, turn off power and consult a qualified electrician.
- The thermoplastic construction is designed for long-term durability and requires no special maintenance beyond cleaning.
7 Issolvi l-problemi
- No Power to Receptacle/Switch:
- Check the circuit breaker or fuse for the circuit. Reset if tripped.
- Verify all wiring connections are secure. Loose connections can interrupt power.
- Neon Pilot Light Not Illuminating:
- Kun żgur li l-iswiċċ ikun fil-pożizzjoni ON.
- Confirm the device is receiving power.
- If the light still does not work, there might be an internal fault, or the wiring configuration does not support the light's intended operation (e.g., if a jumper tab was broken for independent operation).
- Difficulty Inserting Plug into Receptacle:
- This is a characteristic of tamper-resistant receptacles. Ensure the plug is aligned correctly and inserted with firm, even pressure.
- Avoid forcing the plug, as this can damage the shutters or the plug itself.
- Switch Not Controlling Receptacle (or vice-versa) as Expected:
- This indicates a wiring configuration issue. Review Section 4.1 "Wiring Diagram Overview" and consult a qualified electrician if necessary. Internal jumpers may need adjustment.
8. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Numru tal-Mudell | TR274W |
| Brand | Eaton |
| Tip ta' Swiċċ | Single-Pole Toggle |
| Tip ta' Reċipjent | Tamper Resistant, 2-Pole, 3-Wire |
| Aqleb AmpErage Kapaċità | 15 Amps |
| Iswiċċ Voltage | 120 Volts |
| Reċipjent AmpErage Kapaċità | 15 Amps |
| Receptacle Voltage | 125 Volts |
| Wattage | 274 Watts |
| Materjal | Thermoplastic, Alloy Steel (mounting strap) |
| Kulur | White (external finish), Black/Brass (internal components/terminals) |
| Dimensjonijiet tal-Prodott | 1.88 x 1.5 x 4.38 pulzieri |
| Piż tal-oġġett | 3.7 uqija |
| Ċertifikazzjoni | Elenkat UL |
| Metodu ta 'Installazzjoni | Invita |
| Tip ta 'Immuntar | Mount Wall |
9. Garanzija u Appoġġ
For warranty information and technical support, please contact Eaton customer service. Details regarding product warranty and support resources can typically be found on the official Eaton website or by contacting their support channels directly. Always refer to the official product packaging or Eaton's webis-sit għall-aktar termini u kundizzjonijiet tal-garanzija attwali.
Eaton Customer Support:
- Żur l-Eaton uffiċjali websit għal riżorsi ta' appoġġ, FAQs, u informazzjoni ta' kuntatt.
- Have your product model number (TR274W) ready when contacting support.