1. Introduzzjoni
The SICCE Voyager HP 10 Stream Pump is designed for efficient water movement in both freshwater and saltwater aquarium environments. This high-performance pump is intended for submerged use and features advanced technology to ensure optimal circulation and a healthy aquatic ecosystem.

Image: The SICCE Voyager HP 10 Stream Pump, a compact black and grey unit with a protective grille, designed for powerful water circulation.
2. Istruzzjonijiet tas-Sigurtà
Please read all safety instructions carefully before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect the pump from the power supply before performing any maintenance, installation, or handling.
- This pump is designed for submerged use only. Do not operate the pump dry.
- Ensure the power outlet is properly grounded and protected by a Ground Fault Circuit Interrupter (GFCI).
- Tħaddimx il-pompa jekk il-korda tal-enerġija jew il-plagg ikunu bil-ħsara.
- Keep the pump and its electrical connections away from children and pets.
- The pump features a protection grid over the impeller to prevent harm to fish. Do not remove this grid during operation.
- Refer to the product packaging for any additional specific safety warnings or instructions.
3. Kontenut tal-Pakkett
Ivverifika li l-komponenti kollha huma preżenti u mhux imħassra malli tiftaħ il-pakkett:
- 1 x SICCE Voyager HP 10 Stream Pump (4000 GPH)
- 1 x Magnetic Support
- Manwal ta 'Istruzzjoni (dan id-dokument)
4. Setup
- Pjazzament: Utilize the exclusive magnetic support to position the pump anywhere within your aquarium. Ensure the pump is fully submerged and positioned to achieve desired water flow patterns.
- Konnessjoni tal-Enerġija: Connect the pump's power cord to a 120 Volt, properly grounded electrical outlet. Ensure a drip loop is formed to prevent water from traveling along the cord to the outlet.
- Start-up Inizjali: Once submerged and connected, the pump will begin operation. Allow a few moments for any trapped air to escape.
5. Operazzjoni
The SICCE Voyager HP 10 Stream Pump is designed for continuous and reliable operation.
- Aġġustament tal-fluss: The pump features a flow adjuster, allowing you to manually change the amount of water flow to suit your aquarium's specific needs.
- Directional Flow: The 360-degree movable rotor allows for precise aiming of the water flow, creating optimal circulation and preventing dead spots in your tank.
- Timer Compatibility: The Voyager range can be turned on and off quickly if combined with an external timer, without generating noise, making it suitable for automated routines.
6. Manutenzjoni
Regular maintenance is crucial for ensuring the long-lasting performance and efficiency of your SICCE Voyager HP 10 Stream Pump.
- Tindif: Periodically inspect the pump for debris accumulation, especially around the impeller and protective grid. Disconnect power before cleaning. The pump features a self-cleaning impeller, but manual cleaning may still be required for optimal performance.
- Spezzjoni tal-Impeller: The pump utilizes a ceramic shaft. Inspect the impeller and shaft for any signs of wear or damage during cleaning.
- Kura Ġenerali: Adhere to a schedule of regular maintenance and care as recommended for aquarium equipment to ensure years of successful operation.
7 Issolvi l-problemi
If you encounter issues with your pump, refer to the following common troubleshooting steps:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-pompa ma tixgħelx. | Bla enerġija, konnessjoni maħlula, sokit difettuż. | Check power cord connection. Test outlet with another device. Verify GFCI is not tripped. |
| Fluss ta 'ilma mnaqqas. | Impeller clogged with debris, flow adjuster setting, air trapped in pump. | Disconnect power and clean impeller. Adjust flow setting. Gently shake pump to release trapped air. |
| Ħoss ta’ twerwir. | Debris in impeller chamber, worn impeller/shaft. | Disconnect power and thoroughly clean the impeller and its chamber. If noise persists after cleaning, contact customer support. |
8. Speċifikazzjonijiet
| Ditta: | Siċċe |
| Mudell: | Voyager HP 10 Stream Pump |
| Rata tal-fluss: | 4000 GPH (gallun fis-siegħa) |
| Sors tal-Enerġija: | Corded Elettriku |
| Voltage: | 120 Volts |
| Piż tal-oġġett: | 1 libbra (madwar 0.45 kg) |
| Dimensjonijiet tal-Prodott (L x W x H): | 7.25 x 4.75 x 4 pulzieri (madwar 18.4 x 12.1 x 10.2 ċm) |
| Applikazzjoni: | Akkwarji tal-Ilma Ħelu u Mielaħ |
| Użu: | Mgħaddas |
9. Garanzija u Appoġġ
For information regarding warranty coverage, product registration, or technical support, please contact Sicce customer service directly or visit their official websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri.
Manifattur: Sicce Usa
Websit: www.sicce.com (Nota: Dan huwa terminu riżervat) URL as the actual support URL was not provided in the JSON. Users should verify the correct URL.)