Milwaukee 2235-20

Milwaukee 2235-20 400 Amp Clamp Manwal ta' Istruzzjoni tal-Meter

Mudell: 2235-20

1. Introduzzjoni

This manual provides detailed instructions for the safe and effective use of the Milwaukee 2235-20 400 Amp Clamp Meter. This heavy-duty True-RMS electrical current tester is designed for professional residential, commercial, and industrial applications. Please read this manual thoroughly before operating the device.

2. Informazzjoni dwar is-Sigurtà

Always adhere to the following safety precautions to prevent personal injury or damage to the meter:

  • Ensure the meter is rated for the voltage and current levels being measured. The 2235-20 is rated CAT III 600V.
  • Do not use the meter if it appears damaged or if the test leads are compromised.
  • Dejjem ilbes tagħmir protettiv personali (PPE) xieraq, bħal nuċċalijiet tas-sigurtà u ingwanti iżolati, meta taħdem ma' ċirkwiti elettriċi.
  • Avoid contact with live circuits. Use the clamp jaw for current measurements to avoid direct contact.
  • Tħaddimx il-miter f'kundizzjonijiet imxarrbin jew f'atmosferi splussivi.
  • Refer to local and national safety codes for electrical work.

3. Kontenut tal-Pakkett

Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett:

  • (1) Milwaukee 2235-20 400 Amp Clamp Miter
  • (1) Electrical Test Lead Set (red and black)
  • (2) Batteriji AAA
  • (1) Manwal ta 'Istruzzjoni
Milwaukee 2235-20 400 Amp Clamp Meter in retail packaging

Figure 1: Milwaukee 2235-20 Clamp Meter in its retail packaging, showing the meter, test leads, and manual.

4. Prodott Aktarview

The Milwaukee 2235-20 Clamp Meter features a robust design for various electrical measurements. Key components include:

  • Clamp Xedaq: For non-contact AC current measurement. Features a 1.0-inch jaw size.
  • Dial tal-Funzjoni: Selects measurement modes (AC Amps, AC/DC Volts, Ohms, Continuity).
  • Display LCD: Black on white display with backlight for clear readings.
  • Test Lead Inputs: Ports for connecting the red and black test leads for voltagkejl ta' e, reżistenza, u kontinwità.
  • Dawl tax-Xogħol LED: Integrated light to illuminate the work area.
  • Buttuna Żomm: Jiffriża l-qari attwali fuq id-displej.
  • Buttuna MIN/MAX: Records minimum and maximum readings.
  • Rugged Over-molding: Provides increased durability and user grip.
Quddiem view of the Milwaukee 2235-20 400 Amp Clamp Miter

Figura 2: Quddiem view of the Milwaukee 2235-20 Clamp Meter, highlighting the display, function dial, clamp jaw, and buttons.

5. Setup

5.1 Installazzjoni tal-batterija

The Milwaukee 2235-20 requires two AAA batteries (included). To install or replace batteries:

  1. Sib l-għatu tal-kompartiment tal-batterija fuq wara tal-miter.
  2. Uża tornavit biex tiftaħ il-kompartiment.
  3. Daħħal żewġ batteriji AAA, waqt li tiżgura l-polarità korretta (+/-).
  4. Ibdel l-għatu u waħħalha bil-kamin.

5.2 Konnessjoni tal-wajers tat-test

Għal voltage, resistance, and continuity measurements, connect the test leads:

  • Daħħal il-wajer tat-test iswed fil-jack tad-dħul "COM" (komuni).
  • Daħħal il-wajer tat-test aħmar fil-"VΩ" (voltagjack tad-dħul (reżistenza e).

6. Istruzzjonijiet Operattivi

Turn the function dial to the desired measurement mode.

6.1 AC Current Measurement (Clamp)

To measure AC current up to 400 Amps:

  1. Set the function dial to the "A~" (AC Amps) pożizzjoni.
  2. Iftaħ il-clamp jaw and enclose a single conductor (not a bundle of wires) of the circuit to be measured.
  3. Ensure the jaw is fully closed around the conductor.
  4. Aqra l-valur kurrenti fuq il-wiri LCD.

6.2 AC/DC Voltage Kejl

Biex tkejjel AC jew DC voltage up to 600 Volts:

  1. Qabbad il-wajers tat-test kif deskritt fit-Taqsima 5.2.
  2. Set the function dial to the "V~" (AC Volts) or "V-" (DC Volts) position.
  3. Touch the test probes to the points in the circuit where voltage għandu jitkejjel.
  4. Aqra l-voltage valur fuq il-wiri LCD.

6.3 Kejl tar-Reżistenza

To measure resistance up to 4000 Ohms:

  1. Qabbad il-wajers tat-test kif deskritt fit-Taqsima 5.2.
  2. Issettja l-arloġġ tal-funzjoni għall-pożizzjoni "Ω" (Ohms).
  3. Kun żgur li ċ-ċirkwit jew il-komponent ma jkollux l-enerġija qabel ma tkejjel ir-reżistenza.
  4. Miss il-probi tat-test tul il-komponent jew iċ-ċirkwit li għandu jitkejjel.
  5. Aqra l-valur tar-reżistenza fuq id-displej LCD.

6.4 Test ta' Kontinwità

Biex tittestja l-kontinwità:

  1. Qabbad il-wajers tat-test kif deskritt fit-Taqsima 5.2.
  2. Set the function dial to the "Ω" (Ohms) position, then press the "SELECT" button (if available, or rotate dial further) to activate continuity mode (indicated by a speaker icon).
  3. Kun żgur li ċ-ċirkwit jew il-komponent ma jkollux l-enerġija.
  4. Touch the test probes across the component or circuit.
  5. An audible tone indicates continuity (low resistance).

6.5 Funzjoni ta' Żomm

Agħfas il- ŻOMM buttuna biex tiffriża l-qari attwali fuq id-displej. Agħfasha mill-ġdid biex tirrilaxxa.

6.6 Funzjoni MIN/MAX

Agħfas il- MIN / MAX button to record the minimum and maximum readings during a measurement session. Press repeatedly to cycle through MIN, MAX, and current readings.

6.7 Dawl tax-Xogħol LED

Agħfas il- LED button (often indicated by a light bulb icon) to turn the integrated work light on or off.

7. Manutenzjoni

7.1 Tindif

Imsaħ il-marka tal-miterasing b'reklamaramp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the meter is dry before storage or use.

7.2 Sostituzzjoni tal-batterija

Ibdel il-batteriji meta jidher l-indikatur ta’ batterija baxxa fuq id-displej. Irreferi għat-Taqsima 5.1 għal struzzjonijiet dwar l-installazzjoni tal-batterija.

7.3 Kalibrazzjoni

For optimal accuracy, it is recommended to send the meter in for calibration service once every year.

8 Issolvi l-problemi

  • Ebda Display: Check battery installation and charge. Replace batteries if necessary.
  • Qari mhux eżatt: Ensure correct function mode is selected. Verify test lead connections. For current, ensure only one conductor is within the clamp jaw. Consider professional calibration if issues persist.
  • No Continuity Tone: Ensure continuity mode is active. Check test leads for damage.

9. Speċifikazzjonijiet

KaratteristikaSpeċifikazzjoni
Numru tal-Mudell2235-20
AC AmpsSa 400 amps
AC VoltageUp to 600 volts
DC VoltageUp to 600 volts
ReżistenzaSa 4000 ohms
Safety Category RatingCAT III 600V
Veru-RMSIva
Daqs tax-Xedaq1.0-il pulzier
WiriBlack on White Display, Backlight
Test ta' KontinwitàIva
Funzjoni MIN/MAXIva
Żomm FunzjoniIva
Dawl tax-Xogħol LEDIva
Sors tal-Enerġija2 Batteriji Alkalini AAA
Piż tal-oġġett1.15 liri
DimensjonijietApproximately 11 inches (27 cm) in length
Milwaukee 2235-20 Clamp Meter with dimensions indicating 11 inches (27 cm) length

Figure 3: Approximate dimensions of the Milwaukee 2235-20 Clamp Metru.

10. Garanzija u Appoġġ

10.1 Informazzjoni dwar Garanzija

The Milwaukee 2235-20 400 Amp Clamp Meter is covered by a 5-year warranty. For specific terms and conditions, please refer to the warranty documentation included with your product or visit the official Milwaukee websit.

10.2 Appoġġ għall-Klijent

For technical assistance, service, or warranty claims, please contact Milwaukee customer support. Contact information can typically be found on the product packaging or the official Milwaukee websit: www.milwaukeetool.com.

You may also refer to the UPC: 045242236930 for product identification.

Dokumenti Relatati - 2235-20

Preview Volum tal-Karozzi ta' Milwaukeetage/Continuity Tester W/ Resistance 2213-20
Volum tal-Karozzi ta' Milwaukeetage/Continuity Tester W/ Resistance (2213-20) offers accurate measurements, a backlit LCD, LED worklight, and auto-ranging for efficient electrical testing. Includes belt clip, test leads, batteries, and manual.
Preview Volum tal-Karozzi ta' MilwaukeetagManwal tal-Operatur tat-Test tal-Kontinwità e/
Manwal tal-operatur għall-Milwaukee 2212-20 u 2213-20 Auto VoltagTesters tal-Kontinwità/e. Jipprovdi struzzjonijiet ta' sigurtà, speċifikazzjonijiet, tħaddim, manutenzjoni, u informazzjoni dwar il-garanzija għall-ittestjar elettriku.
Preview Milwaukee MW805 MAX Portable pH EC TDS Temperature Meter Instruction Manual
Instruction manual for the Milwaukee MW805 MAX portable meter, covering pH, EC, TDS, and temperature measurements. Learn about features, operation, calibration, and maintenance.
Preview Manwal tal-Utent tal-Miter tal-pH/EC/TDS Portabbli Milwaukee MW801 & MW802
Manwal tal-utent għall-miters portabbli tal-pH/EC/TDS ta' Milwaukee, mudelli MW801 u MW802. Jinkludi t-tħaddim, il-kalibrazzjoni, il-manutenzjoni, u l-ispeċifikazzjonijiet.
Preview Lista tal-Partijiet tas-Servizz tal-Impact Wrenches Milwaukee M18 FUEL ONE KEY
Lista uffiċjali tal-partijiet tas-servizz għall-Milwaukee M18 FUEL ONE KEY Impact Wrenches (mudelli 2862-20, 2863-20, 2864-20). Tinkludi n-numri tal-partijiet, id-deskrizzjonijiet, u l-informazzjoni ta' kuntatt tas-servizz għal Milwaukee Electric Tool.
Preview Manwal tal-Istruzzjonijiet tal-Miter Portabbli Milwaukee MW805 MAX
Manwal ta' struzzjonijiet komprensiv għall-miter portabbli Milwaukee MW805 MAX, li jiddeskrivi l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, il-kalibrazzjoni, il-manutenzjoni u s-soluzzjoni tal-problemi għall-kejl tal-pH, EC, TDS u temperatura.