1. Prodott Aktarview
The CyberPower CP1350PFCLCD is a mini-tower Uninterruptible Power Supply (UPS) system designed to provide battery backup and surge protection. It features sine wave output, making it compatible with active Power Factor Correction (PFC) and conventional power supplies. This unit safeguards desktop computers, workstations, networking devices, and home entertainment systems from power fluctuations and outages. An advanced multifunction color LCD panel provides real-time status and alerts, with a tilt feature for optimal viewing.
The UPS incorporates Automatic Voltage Regulation (AVR) to stabilize incoming utility power, correcting minor voltage fluctuations without engaging the battery, thereby extending battery life.

Figura 1: Quddiem view of the CyberPower CP1350PFCLCD UPS, showing the LCD display and control buttons.
2. Setup
2.1 Żpakkjar u Spezzjoni Inizjali
Carefully remove the UPS from its packaging. Inspect the unit for any signs of damage. Ensure all components, including the power cord and user manual, are present.
2.2 Konnessjoni tal-batterija
The UPS battery may be disconnected for shipping. To connect the battery:
- Locate the battery compartment cover, typically at the bottom or side of the unit.
- Remove the cover by sliding it or unscrewing retaining screws.
- Connect the internal battery cables (red to red, black to black) as indicated. Ensure connections are secure.
- Ibdel l-għatu tal-kompartiment tal-batterija.
2.3 Konnessjoni mal-Enerġija u l-Apparati
Plug the UPS power cord into a grounded wall outlet. Connect your computer, monitor, and other critical equipment to the battery backup and surge-protected outlets on the rear of the UPS. Non-critical devices can be connected to surge-only outlets.

Figura 2: Wara view of the UPS, showing 12 NEMA 5-15R outlets (six battery backup & surge protected, six surge protected), network ports, USB, and serial port.
3. Istruzzjonijiet Operattivi
3.1 Tixgħel/Jitfi
To power on the UPS, press and hold the power button on the front panel until the LCD screen illuminates. To power off, press and hold the power button again until the display turns off.
3.2 Wiri u Kontrolli tal-LCD
The multifunction color LCD panel displays real-time information about the UPS status. Use the 'DISPLAY' button to cycle through various screens, including:
- Input Voltage: Shows the incoming utility power voltage.
- Ħruġ Voltage: Juri l-voltage fornuta mill-UPS lil apparati konnessi.
- Kapaċità tal-batterija: Indicates the current charge level of the battery.
- Tagħbija kurrenti: Shows the power consumption of connected devices.
- Ħin tal-Eżekuzzjoni Stima: Provides an approximation of how long the UPS can power connected devices during an outage.
- Ġurnal tal-Avvenimenti: Records power events such as outages jew żidiet.
The screen can be tilted up to 22 degrees for better viewangoli.

Figure 3: Close-up of the LCD panel displaying various status icons and real-time data.
3.3 Vol. AwtomatikutagRegolament (AVR)
The UPS automatically activates AVR to correct minor voltage fluctuations (sags or surges) without switching to battery power. This ensures a stable power supply to your devices and prolongs battery life.
3.4 Portijiet tal-Iċċarġjar tal-USB
The front panel includes USB-A and USB-C ports for convenient charging of mobile devices, even during a power outage.
4. Manutenzjoni
4.1 Sostituzzjoni tal-batterija
Over time, UPS batteries will degrade and require replacement. The CP1350PFCLCD uses two 12V sealed lead-acid batteries. The LCD panel may display an error code (e.g., E21) or a 'REPLACE' icon when the battery needs attention.
Procedure for Battery Replacement:
- Kun żgur li l-UPS huwa mitfi u skonnettjat mis-sokit tal-ħajt.
- Remove the battery compartment cover (usually secured by two Phillips screws).
- Carefully disconnect the battery terminals (red and black) from the old batteries. Note the orientation for proper re-connection.
- Remove the old batteries. They may be snug and require gentle nudging.
- Insert the new batteries, ensuring they fit correctly.
- Connect the new battery terminals (red to red, black to black). A small spark may occur during the final connection; this is normal.
- Erġa’ poġġi l-għatu tal-kompartiment tal-batterija u waħħalha bil-viti.
For a visual guide on battery replacement, refer to the official product video below:
Video 1: CyberPower PFC Compatible Pure Sine Wave Tower UPS - This video demonstrates the features and setup of a CyberPower UPS, including aspects relevant to battery maintenance.
4.2 Kura Ġenerali
Keep the UPS in a well-ventilated area, free from dust and moisture. Avoid placing it near heat sources. Regularly check for any loose connections or signs of wear.
5 Issolvi l-problemi
If your UPS is not functioning as expected, refer to the following common issues:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-UPS ma jixgħelx | Batterija mhux imqabbda jew skarikata | Ensure battery is connected. Charge UPS for at least 8 hours. |
| Il-UPS jagħmel ħoss kontinwu | Tagħbija żejda jew batterija baxxa | Reduce connected load. Allow battery to charge. |
| Error Code E21 on LCD | Battery fault or end-of-life | Replace the battery as per maintenance instructions. |
| Ebda enerġija għall-ħwienet | Circuit breaker waqaf | Agħfas il-buttuna tar-reset tas-circuit breaker fuq il-pannell ta' wara. |
6. Speċifikazzjonijiet
- Mudell: CP1350PFCLCD
- Kapaċità: 1350VA / 880W
- Topoloġija: Line Interactive with PFC Sinewave Output
- Ħwienet: 12 NEMA 5-15R (6 Battery Backup & Surge Protected, 6 Surge Protected)
- Input Voltage: 120 Volts
- Tip ta 'batterija: Sealed Lead Acid (2 x 12V batteries included)
- Vol. Awtomatikutage Regolament (AVR): Iva
- Wiri: Multifunction Color LCD Panel
- Dimensjonijiet: 14.2 x 3.9 x 10.4 pulzieri
- Piż tal-oġġett: 20.3 liri
7. Garanzija u Appoġġ
The CyberPower CP1350PFCLCD comes with a garanzija ta' tliet snin, which includes coverage for the batteries. Additionally, it is backed by a $425,000 Connected Equipment Guarantee, providing peace of mind for your connected electronics.
For further support, troubleshooting, or warranty claims, please visit the official CyberPower websit jew ikkuntattja lis-servizz tal-konsumatur tagħhom.