Introduzzjoni
Welcome to your APC Back-UPS Pro 1500VA 230V Power Saving Uninterruptible Power Supply. This manual provides essential information for the safe and efficient operation of your UPS, designed to protect your electronic equipment from power outages, surges, and fluctuations. Please read this manual thoroughly before installation and use.
Prekawzjonijiet tas-Sigurtà
- Periklu ta' Xokk Elettriku: This UPS contains hazardous voltages. Do not attempt to disassemble the unit. Servicing should only be performed by qualified personnel.
- L-ert kif suppost: Always connect the UPS to a grounded outlet. Do not remove the grounding prong from the power cord.
- Użu fuq ġewwa biss: This product is intended for indoor use only. Do not install the UPS in direct sunlight, near heat sources, or in areas with excessive moisture.
- Ventilazzjoni: Aċċerta ruħek li jkun hemm fluss tal-arja adegwat madwar il-UPS. Timblokkax il-fetħiet tal-ventilazzjoni.
- Sigurtà tal-batterija: Batteries can present a risk of electrical shock and high short-circuit current. Observe all precautions when replacing batteries. Use only APC-approved replacement batteries (RBC154).
- Protezzjoni ta' tagħbija żejda: Do not overload the UPS. Ensure the total power draw of connected equipment does not exceed the UPS's capacity.
Kontenut tal-Pakkett
Iċċekkja li l-oġġetti kollha elenkati hawn taħt huma inklużi fil-pakkett tiegħek:
- APC Back-UPS Pro 1500VA 230V UPS Unit
- Manwal għall-Utent (dan id-dokument)
- Korda tal-Enerġija
- Cable tal-Komunikazzjoni USB
Prodott Overview
The APC Back-UPS Pro 1500VA 230V is a tower form factor UPS providing reliable battery backup and surge protection for your critical electronic equipment.
Karatteristiċi tal-Panew ta 'quddiem

Quddiem view of the APC Back-UPS Pro 1500VA unit, showing the LCD display and control buttons.
- Display LCD: Provides real-time status information including input/output voltage, load level, battery charge, and estimated runtime.
- Buttuna tal-Qawwa: Turns the UPS unit on or off.
- Buttuna tad-displej: Cycles through various display screens to show different operational parameters.
- Mute/Setup Button: Mutes audible alarms or enters setup mode for configuration.
- USB-A and USB-C Charging Ports: Conveniently located for charging mobile devices.
Karatteristiċi tal-Panew ta 'wara

Wara view of the APC Back-UPS Pro 1500VA unit, showing the power outlets, data ports, and main power input.
- Sokits ta' Backup tal-Batterija u Protetti minn Żieda fil-Vultaġġ: Ipprovdi l-enerġija mill-batterija waqt li tkun qed tużahatages and protect against surges. Connect critical equipment here.
- Ħwienet ta 'Żieda Biss: Provide surge protection only. Connect non-critical equipment here.
- Input tal-Enerġija Prinċipali: Jgħaqqad il-UPS mas-sokit tal-ħajt.
- Circuit Breaker: Provides overload protection for the UPS. Press to reset if tripped.
- Port tal-Komunikazzjoni USB: Jgħaqqad il-UPS ma' kompjuter għal softwer tal-ġestjoni tal-enerġija.
- Ethernet/Network Protection Ports: Protects network connections from surges.
Setup
- Ħoll u Spezzjona: Carefully unpack the UPS and all accessories. Inspect for any shipping damage.
- Qabbad il-Batterija Interna: The UPS battery may be disconnected for shipping. Refer to the battery compartment access panel (usually at the bottom or rear) and connect the battery terminals as indicated.
- Position the UPS: Place the UPS in a location with adequate ventilation, away from direct sunlight, excessive heat, or moisture. Ensure the front and rear vents are unobstructed.
- Qabbad ma' Wall Outlet: Plug the UPS power cord directly into a grounded 230V wall outlet. Avoid using extension cords or surge protectors with the UPS input.
- Ħlas Inizjali: Allow the UPS to charge for at least 24 hours before connecting any equipment to ensure maximum battery runtime. The battery indicator on the LCD will show charging status.
- Qabbad Tagħmir:
- Plug critical equipment (e.g., computer, monitor, router) into the Backup tal-Batterija u Protezzjoni minn Żieda fil-Vultaġġ ħwienet.
- Plug non-critical equipment (e.g., printer, scanner) into the Żieda Biss ħwienet.
- Qabbad il-Linji tad-Data (Mhux obbligatorju): Connect your USB communication cable from the UPS to your computer to enable power management software features. Connect network cables to the Ethernet protection ports if desired.
Istruzzjonijiet Operattivi
Tixgħel/Jitfi
- Biex Tixgħel: Press and hold the Power button on the front panel until you hear a beep and the LCD display illuminates.
- Biex Tintefa: Press and hold the Power button until the LCD display turns off.
Navigazzjoni tal-Wiri LCD
- Press the Display button repeatedly to cycle through various information screens, including: Input Voltage, Vol Outputtage, Load in Watts, Load in VA, Battery Charge Percentage, and Estimated Runtime.
Ġestjoni tal-allarm
- Waqt qawwa outage, the UPS will emit an audible alarm. Press the Mute/Setup button briefly to temporarily silence the alarm.
- To permanently disable or enable alarms, refer to the detailed instructions in the full user manual or power management software.
Manutenzjoni
Sostituzzjoni tal-batterija
- The typical battery life is 3-5 years, depending on usage and environmental conditions.
- When the battery needs replacement, the UPS will indicate this on the LCD display and may emit an alarm.
- Use only genuine APC replacement battery cartridges (RBC154) to ensure optimal performance and safety. Refer to the full user manual for detailed battery replacement instructions.
Tindif
- Regularly clean the exterior of the UPS with a dry cloth.
- Ensure ventilation openings are free from dust and debris to prevent overheating.
Ħażna
- If storing the UPS for an extended period, ensure the battery is fully charged.
- Store the unit in a cool, dry location with adequate ventilation.
- Recharge the battery every 3-6 months to prevent permanent damage.
Issolvi l-problemi
Hawn taħt jinsabu kwistjonijiet komuni u s-soluzzjonijiet potenzjali tagħhom:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| UPS mhux se jixgħel | Battery disconnected or low charge; UPS not plugged in. | Ensure battery is connected. Plug UPS into a live wall outlet and allow to charge. |
| Ħin qasir ta' tħaddim tal-batterija | Overloaded; battery old or not fully charged. | Reduce connected load. Allow battery to charge for 24 hours. Replace battery if old. |
| UPS emits continuous alarm | On battery mode; overload; battery fault. | Check power source. Reduce load. Check battery status on LCD. |
| Ebda enerġija għall-ħwienet | UPS off; circuit breaker tripped; battery fault. | Turn UPS on. Reset circuit breaker. Check battery status. |
Speċifikazzjonijiet Tekniċi
| Karatteristika | Speċifikazzjoni |
|---|---|
| Numru tal-Mudell | BR1500GI |
| Dimensjonijiet tal-Prodott | 4.41 x 15.04 x 11.89 pulzieri |
| Piż tal-oġġett | 27.9 liri |
| Voltage | 230 Volts |
| Batteriji | Meħtieġa 1 batteriji ta' 12V (inklużi) |
| Kompożizzjoni taċ-Ċellola tal-Batterija | Aċidu taċ-Ċomb |
| Kulur | Iswed |
| Materjal | Metall |
| Fattur tal-Formola | Torri |
Garanzija u Appoġġ
For detailed warranty information, product registration, and technical support, please visit the official APC by Schneider Electric webis-sit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal kwalunkwe talba ta' garanzija.
Tista' ssib riżorsi addizzjonali u informazzjoni ta' kuntatt fuq APC by Schneider Electric Store on Amazon.