Littelfuse SC-30

Manwal tal-Istruzzjonijiet tal-Fjus Littelfuse Bussmann SC-30

1. Introduzzjoni

This manual provides essential information for the safe and effective use of the Littelfuse Bussmann SC-30 Fuse. It covers product overview, safety guidelines, installation, and specifications. Please read this manual thoroughly before handling or installing the fuse.

2. Informazzjoni dwar is-Sigurtà

WARNING: Electrical shock hazard. Always disconnect power before installing or replacing fuses. Installation should only be performed by qualified personnel.

  • Ensure the power supply is completely disconnected and locked out before any work involving fuses.
  • Never touch electrical components with wet hands or while standing on wet surfaces.
  • Dejjem uża fjusis bil-vol korretttage u amperage ratings for the circuit they are protecting. Using an incorrect fuse can lead to equipment damage, fire, or personal injury.
  • Ma bypass jew tamper bil-fjużijiet.
  • Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses, when working with electrical systems.

3. Prodott Aktarview

The Littelfuse Bussmann SC-30 is a Class G, time-delay cartridge fuse designed for general purpose basic protection against overcurrents. It is rated for 30 Amperes and suitable for both AC (480V) and DC (300V) applications. The time-delay characteristic allows for temporary overcurrents, such as motor starting surges, without blowing, while still providing protection against sustained overloads and short circuits.

Bussmann SC-30 Class G Time-Delay Fuse with green label

Figura 3.1: Quddiem view of the Bussmann SC-30 fuse, showing the green label with "BUSS Class G Fuse Type Ampere SC-30 Time-Delay" markings.

Bussmann SC-30 General Purpose Time-Delay Class G Fuse with white label

Figura 3.2: Ġenb view of the Bussmann SC-30 fuse, displaying detailed specifications including "General Purpose Basic Protection Time-Delay Class G Fuse SC-30 480Vac AC IR 100kA 300Vdc DC IR 10kA".

4. Installazzjoni

Follow these steps for proper installation of the SC-30 fuse:

  1. Ivverifika l-Kompatibbiltà: Ensure the SC-30 fuse matches the required amperage u voltage ratings for your specific electrical circuit and equipment. Refer to your equipment's documentation.
  2. Skonnettja l-Enerġija: Absolutely ensure all power to the circuit where the fuse will be installed is turned off and locked out. Use a voltage tester to confirm the circuit is de-energized.
  3. Neħħi l-Fjus il-Qadim (jekk applikabbli): Carefully remove the existing fuse from its holder. Note its orientation if it's a specific type.
  4. Daħħal Fjus Ġdid: Insert the Bussmann SC-30 fuse into the fuse holder. Ensure it is seated firmly and correctly. Do not force the fuse.
  5. Irrestawra l-Enerġija: Once the fuse is securely in place and all safety checks are complete, restore power to the circuit.
  6. Funzjonalità tat-Test: Verify that the protected equipment operates as expected.

Note: Fuses are designed for one-time use. A blown fuse must be replaced with a new one of the identical type and rating.

5. Prinċipju Operattiv

The Bussmann SC-30 fuse functions as a sacrificial device designed to protect electrical circuits from overcurrent conditions. When the current flowing through the circuit exceeds the fuse's 30 Ampere rating for a sustained period (due to an overload) or instantaneously (due to a short circuit), the metallic element inside the fuse melts, creating an open circuit. This action interrupts the flow of electricity, preventing damage to wiring, equipment, and reducing the risk of fire.

As a time-delay fuse, the SC-30 is engineered to withstand temporary current surges that are common during the startup of motors or other inductive loads. This prevents nuisance blowing while still providing reliable protection against harmful overcurrents.

6. Manutenzjoni

Fuses are generally maintenance-free components. However, periodic visual inspection of the fuse and its holder is recommended, especially in environments prone to vibration, dust, or extreme temperatures. Look for any signs of physical damage, discoloration, or loose connections. If any issues are observed, disconnect power and address them immediately.

7 Issolvi l-problemi

If a circuit protected by an SC-30 fuse stops functioning, the fuse may have blown. Follow these troubleshooting steps:

  • Identifika l-Fjus Maħruq: Disconnect all power to the circuit. Visually inspect the fuse for a broken filament or discoloration, which indicates it has blown. Some fuse holders may have an indicator.
  • Determine Cause: A blown fuse indicates an overcurrent condition. Investigate the circuit for potential causes such as:
    • Ċirkwit mgħobbi żżejjed (wisq apparati qed jiġbdu l-enerġija).
    • Short circuit in wiring or equipment.
    • Faulty equipment connected to the circuit.
  • Ibdel il-Fjus: Once the cause of the overcurrent is identified and rectified, replace the blown fuse with a new Littelfuse Bussmann SC-30 fuse. Never replace it with a fuse of a different rating.
  • Repeated Blowing: If the fuse blows repeatedly after replacement, it indicates a persistent problem in the circuit or equipment. Consult a qualified electrician to diagnose and repair the issue.

8. Speċifikazzjonijiet

SpeċifikazzjoniValur
BrandLittelfuse (Bussmann)
Numru tal-MudellSC-30
AmpKlassifikazzjoni tal-qtugħ30 Amps
AC VoltagKlassifikazzjoni e480 Vak
DC VoltagKlassifikazzjoni e300Vdc
Interrupting Rating (AC)100 kA
Interrupting Rating (DC)10 kA
Tip ta 'FjusClass G, Time-Delay
MaterjalRam
Tip ta 'ImmuntarSurface Mount (Cartridge)
Piż tal-oġġett0.317 uqija
Dimensjonijiet tal-Pakkett2.56 x 1.1 x 0.43 pulzieri

9. Garanzija u Appoġġ

For warranty information and technical support regarding your Littelfuse Bussmann SC-30 fuse, please refer to the official Littelfuse webis-sit jew ikkuntattja lis-servizz tal-konsumatur tagħhom direttament. Żomm l-irċevuta tax-xiri tiegħek għal kwalunkwe talba ta' garanzija.

Uffiċjal ta' Littelfuse Websit: www.littelfuse.com

Dokumenti Relatati - SC-30

Preview Fjusis Littelfuse JLLN Series Klassi T | Azzjoni Rapida, Kapaċità Għolja ta' Interruzzjoni
Esplora l-fjużijiet Littelfuse JLLN Series Class T, li joffru disinn kompatt, protezzjoni kontra tagħbija żejda u short circuit li taħdem malajr, u klassifikazzjonijiet ta' interruzzjoni għoljin sa 200,000 AIR. Ideali għal drives, inverters, u provvisti tal-enerġija. View speċifikazzjonijiet, informazzjoni dwar l-ordnijiet, u dimensjonijiet.
Preview Fjusis ta' Veloċità Għolja Littelfuse POWR-SPEED L70QS Serje - Dejta Teknika
Esplora l-fjusis ta' veloċità għolja Littelfuse POWR-SPEED® L70QS Series. Din il-folja tad-dejta tipprovdi speċifikazzjonijiet dettaljati, dimensjonijiet, kurvi tal-ħin-kurrent, u informazzjoni dwar l-applikazzjoni għal dawn il-fjusis ta' 700V ac/dc, iddisinjati għall-protezzjoni ta' apparati semikondutturi tal-enerġija f'applikazzjonijiet industrijali.
Preview Istruzzjonijiet għall-Installazzjoni tal-Fjus Littelfuse Sealed M10 ZCASE
Istruzzjonijiet għall-installazzjoni tal-Littelfuse Sealed M10 ZCASE Fuse, inklużi l-ispeċifikazzjonijiet, l-informazzjoni dwar l-ordnijiet, u l-gwida tal-assemblaġġ pass pass.
Preview Gwida għall-Modifika tal-Proporzjon tad-Dawriet tas-CT: Nota Teknika ta' Littelfuse
Tgħallem kif timmodifika l-proporzjon tad-dawriet tat-transformers tal-kurrent Littelfuse (CTs) b'din in-nota teknika, inklużi metodi għaż-żieda u t-tnaqqis tad-dawriet, u eżempji prattiċi.ampIfhem il-prinċipji tat-tħaddim tas-CT u l-aġġustamenti tal-proporzjon.
Preview Detentur tal-Fjusijiet Bolt-Down tas-Serje Littelfuse MEGA® Flex
Skopri l-Littelfuse MEGA® Flex Series 32V Bolt-Down Fuse Holder, iddisinjat għal applikazzjonijiet ta' kurrent għoli sa 500 amps. Tgħallem dwar il-karatteristiċi, il-benefiċċji u l-informazzjoni dwar l-ordnijiet ta' dan id-detentur tal-fjus versatili.
Preview Relays tal-Protezzjoni Littelfuse: Katalogu Komprensiv għas-Sigurtà u l-Effiċjenza Industrijali
Explore the Littelfuse range of protection relays, including advanced solutions for ground-fault protection, arc-flash mitigation, motor and pump monitoring, feeder protection, and neutral grounding systems. Enhance industrial safety and operational efficiency.