1. Introduzzjoni
The LINEAR SEG-1 IEI Secured Ethernet Gateway is designed to facilitate secure communication between IEI access control systems and a network. It converts TCP/IP data to serial data, enabling access systems to send and receive information over a standard network. This allows for programming and management of the access panel from any network-connected PC running Hub Manager Professional (version 5.0 or higher).
2. Prodott Aktarview
The SEG-1 gateway features a compact design with essential ports and indicators for network and serial communication.

Figura 1: Quddiem view of the LINEAR SEG-1 IEI Secured Ethernet Gateway. The front panel includes an Ethernet port labeled "NETWORK", two serial ports labeled "RS232" and "RS485", and indicator LEDs for status.
Il-komponenti ewlenin jinkludu:
- NETWORK Port: RJ45 Ethernet connector for TCP/IP communication.
- Port RS232: Port ta' komunikazzjoni serjali.
- Port RS485: Port ta' komunikazzjoni serjali.
- LEDs tal-istatus: Indicators for power, network activity, and data transmission.
3. Istruzzjonijiet ta' Setup
Follow these steps to properly set up your SEG-1 gateway:
- Immuntar: Securely wall mount the SEG-1 unit using separately provided hardware. Choose a location that allows for easy access to power and network connections, and is within range of the IEI access panel.
- Konnessjoni tal-Enerġija: Connect a separate 12VDC power supply (150 mA maximum) to the SEG-1. A modular cord is provided for communication with the access panel, which may also carry power depending on the specific access panel model. Ensure the power supply is stable and meets the specified requirements.
- Konnessjoni tan-Netwerk: Connect an Ethernet cable from your network router or switch to the "NETWORK" RJ45 port on the SEG-1 gateway. Verify that the network connection is active (indicated by corresponding LEDs).
- Konnessjoni Serjali: Connect the appropriate serial cable from the IEI access panel to either the "RS232" or "RS485" port on the SEG-1, depending on the access panel's serial interface.
- Konfigurazzjoni tas-Softwer: Install and configure Hub Manager Professional (version 5.0 or higher) on a network-connected PC. Refer to the Hub Manager Professional manual for detailed software setup and gateway integration instructions.
4. Istruzzjonijiet Operattivi
Once properly installed and configured, the SEG-1 gateway operates as an interface between your network and the IEI access control system.
- Konverżjoni tad-Data: The gateway automatically converts TCP/IP data from the network to serial data for the access panel, and vice-versa.
- Ġestjoni mill-bogħod: Use Hub Manager Professional on a networked computer to manage and program the IEI access system. All commands and data will be routed through the SEG-1 gateway.
- Monitoraġġ tal-Istat: Observe the status LEDs on the front panel for indications of power, network link, and data activity. Refer to the LED indicator section (if available in a more detailed manual) for specific meanings.
5. Manutenzjoni
The LINEAR SEG-1 gateway requires minimal maintenance to ensure optimal performance.
- Tindif: Periodically clean the exterior of the unit with a soft, dry cloth. Avoid using liquid cleaners or solvents.
- Kundizzjonijiet Ambjentali: Ensure the unit is operated within its specified temperature and humidity ranges. Avoid exposing the unit to excessive dust, moisture, or direct sunlight.
- Aġġornamenti tal-Firmware: Check the LINEAR website periodically for any available firmware updates for the SEG-1 gateway. Follow the provided instructions carefully for any update procedures.
6 Issolvi l-problemi
If you encounter issues with your SEG-1 gateway, consider the following troubleshooting steps:
- Ebda Qawwa:
- Verify the 12VDC power supply is correctly connected and functioning.
- Iċċekkja l-kejbils u l-konnessjonijiet kollha tal-enerġija.
- Ebda Konnettività man-Netwerk:
- Ensure the Ethernet cable is securely connected to both the SEG-1 and the network device (router/switch).
- Check network status LEDs on the SEG-1 and the network device.
- Confirm network settings on the PC running Hub Manager Professional.
- Communication Errors with Access Panel:
- Verify the correct serial port (RS232 or RS485) is being used and the cable is properly connected.
- Ensure the IEI access panel is powered on and functioning correctly.
- Check the configuration settings within Hub Manager Professional for the correct gateway and access panel parameters.
- Hub Manager Professional Connection Issues:
- Confirm that Hub Manager Professional (v5.0 or higher) is installed and configured correctly.
- Ensure the PC is on the same network as the SEG-1 gateway.
- Check for any firewall settings on the PC or network that might be blocking communication.
7. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Mudell | SEG-1 |
| Funzjoni | TCP/IP to Serial Data Converter |
| Kompatibilità | IEI Access Systems, Hub Manager Professional (v5.0+) |
| Rekwiżit ta' Enerġija | 12VDC, 150 mA max (separate power supply required) |
| Immuntar | Wall mount (hardware not included) |
| Konnettività | Ethernet (RJ45), RS232, RS485 |
| Piż tal-oġġett | 15 liri |
| Manifattur | LINEAR RESEARCH |
| Data L-Ewwel Disponibbli | 20 ta’ Diċembru 2010 |
8. Informazzjoni dwar Garanzija
For detailed warranty information regarding the LINEAR SEG-1 IEI Secured Ethernet Gateway, please refer to the warranty card included with your product packaging or visit the official LINEAR websit. It-termini u l-kundizzjonijiet tal-garanzija jistgħu jvarjaw skont ir-reġjun u d-data tax-xiri.
9. Appoġġ Tekniku
If you require technical assistance or have questions not covered in this manual, please contact LINEAR customer support. Contact information can typically be found on the manufacturer's webis-sit jew fuq l-imballaġġ tal-prodott.
Note: Always ensure you have your product model number (SEG-1) and any relevant purchase information available when contacting support.





