1. Prodott Aktarview
The Forney 58402 is a heavy-duty Bakelite pin-type wall electrical receptacle designed for surface mounting. It features a 2-pole/3-wire grounding configuration, suitable for high-power applications. This receptacle is rated for 50 Amps at 125/250 Volts and conforms to NEMA 6-50 standards.
Karatteristiċi ewlenin:
- Heavy duty Bakelite pin-type design for durability.
- Wall electrical receptacle for surface mounting.
- 2-pole/3-wire grounding for enhanced safety.
- 50 Amp with 125/250-Volt capacity.
- NEMA 6-50 electrical configuration.

Figura 1: Quddiem view of the Forney 58402 Electrical Receptacle, showing the pin configuration and voltage/ampklassifikazzjonijiet tal-qtugħ.
2. Informazzjoni dwar is-Sigurtà
TWISSIJA: Electrical work can be hazardous. Always disconnect power at the circuit breaker or fuse box before installing, servicing, or removing this receptacle. Failure to do so may result in serious injury or death. If you are unsure about any part of these instructions, consult a qualified electrician.
- Kun żgur li l-kodiċijiet elettriċi lokali u nazzjonali kollha jiġu segwiti.
- Uża tagħmir protettiv personali (PPE) xieraq, bħal ingwanti iżolati u nuċċalijiet tas-sigurtà.
- Ivverifika l-voltage u amperage of your circuit match the receptacle's ratings (50A, 125/250V).
- Do not use this receptacle if it appears damaged.
- Żomm lit-tfal 'il bogħod minn installazzjonijiet elettriċi.
3. Setup u Installazzjoni
This section provides general guidelines for installing the Forney 58402 wall receptacle. Specific wiring configurations may vary based on local codes and existing electrical systems.
Għodda u Materjali Meħtieġa:
- Tornaviti (Phillips u Flathead)
- prodotti għat-tqaxxir tal-wajer
- Voltagtester
- Mounting screws (appropriate for surface)
- Electrical box (if not already present)
Passi ta' Installazzjoni:
- Skonnettja l-Enerġija: Locate the circuit breaker or fuse controlling the circuit where the receptacle will be installed and turn it OFF. Verify power is off using a voltagtester.
- Ipprepara l-Wiċċ tal-Immuntar: Ensure the surface is clean, dry, and structurally sound. The receptacle is designed for surface mounting.
- Mount the Receptacle Base: Position the receptacle base on the desired surface. Use appropriate mounting screws to secure it firmly. The back of the receptacle features pre-drilled holes for this purpose.
- Konnessjonijiet tal-Wajer: This receptacle is a 2-pole/3-wire grounding type (NEMA 6-50). It typically requires two hot wires (L1, L2) and one ground wire.
- Neħħi madwar nofs pulzier ta' insulazzjoni minn kull wajer.
- Connect the L1 (Hot) wire to one of the brass-colored terminals.
- Connect the L2 (Hot) wire to the other brass-colored terminal.
- Connect the Ground wire (typically green or bare copper) to the green hexagonal grounding screw.
- Wiring Sikur: Ensure all wire connections are tight and secure. No bare wire should be exposed outside the terminals.
- Erġa' arma: Carefully place the cover over the wired base and secure it with the provided screws.
- Irrestawra l-Enerġija: Once installation is complete and verified, turn the power back ON at the circuit breaker or fuse box.

Figura 2: Lura view of the Forney 58402 Receptacle, showing the metal mounting plate and screw holes for surface installation.

Figura 3: Qiegħ view of the Forney 58402 Receptacle, illustrating the internal wiring access points and terminals.
4. Istruzzjonijiet Operattivi
The Forney 58402 Electrical Receptacle is designed for straightforward operation.
- Ivverifika l-Kompatibbiltà: Ensure the plug of your electrical device is compatible with the NEMA 6-50 configuration of this receptacle.
- Daħħal il-Plagg: Align the pins of your device's plug with the slots on the receptacle and firmly insert the plug.
- Neħħi l-Plagg: To disconnect, grasp the plug firmly and pull it straight out from the receptacle. Do not pull by the cord.

Figura 4: Close-up view of the Forney 58402 Receptacle's pin configuration, showing the 50A 250V markings.
5. Manutenzjoni
Regular inspection and basic maintenance will help ensure the longevity and safe operation of your Forney 58402 receptacle.
- Spezzjoni Perjodika: Annually inspect the receptacle for any signs of damage, cracks, discoloration, or loose connections.
- Tindif: With power disconnected, gently wipe the exterior of the receptacle with a dry, clean cloth to remove dust or debris. Do not use liquid cleaners.
- Issikka l-Konnessjonijiet: If comfortable and with power disconnected, periodically check and tighten the terminal screws to ensure secure wire connections.
- Protezzjoni Ambjentali: Jekk installati fl adamp or dusty environment, ensure the receptacle is adequately protected from moisture and excessive dust accumulation.
6 Issolvi l-problemi
If you experience issues with your Forney 58402 receptacle, consider the following common troubleshooting steps:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| No power from receptacle | Circuit breaker tfixkel jew fjus minfuħ | Iċċekkja l-pannell elettriku tiegħek u irrisettja l-interruttur jew ibdel il-fjus. |
| No power from receptacle | Konnessjoni tal-wajers sfużi | With power disconnected, inspect and tighten all wire connections within the receptacle. |
| Il-plagg ma joqgħodx | Tip ta' plagg inkompatibbli | Ensure your device's plug is a NEMA 6-50 type. Do not force incompatible plugs. |
| Ir-reċipjent iħoss sħun | Tagħbija żejda jew konnessjoni maħlula | Immediately disconnect power. Reduce load or check wiring. Consult an electrician if problem persists. |
If troubleshooting steps do not resolve the issue, or if you are unsure, contact a qualified electrician.
7. Speċifikazzjonijiet
| Attribut | Valur |
|---|---|
| Brand | Forney |
| Mudell | 58402 |
| Tip | Pin-Type Wall Receptacle |
| Ampetà | 50 Amps |
| Voltage | 125/250 Volts |
| Konfigurazzjoni NEMA | 6-50 |
| Arbli/Wires | 2-Pole, 3-Wire Grounding |
| Materjal | Bakelite (Housing), Plastic (Body) |
| Kulur | Iswed |
| Ħwienet tal-Enerġija Totali | 1 |
| Apparati Kompatibbli | All (NEMA 6-50 compatible) |
8. Garanzija u Appoġġ
Specific warranty details for the Forney 58402 Electrical Receptacle are not provided in this manual. For warranty information, technical support, or service inquiries, please refer to the product packaging or contact Forney customer service directly.
You may visit the official Forney websit għal informazzjoni ta' kuntatt u riżorsi addizzjonali: www.forneyind.com