1. Introduzzjoni
The Taylor Digital Turbo Read Thermocouple Thermometer with Folding Probe is designed for quick and accurate temperature measurements. Its compact design and rapid response time make it suitable for various culinary applications. This manual provides essential information for the proper use, care, and maintenance of your thermometer.
Image 1.1: The Taylor Digital Turbo Read Thermocouple Thermometer in yellow, featuring a digital display and a folding probe.
2. Informazzjoni dwar is-Sigurtà
- Sigurtà tas-Sonda: Il-ponta tas-sonda hija qawwija. Immaniġġja b'attenzjoni biex tevita korriment.
- Reżistenza għas-Sħana: The thermometer body is not designed for high heat. Do not leave the thermometer in an oven, grill, or microwave during cooking. Only the stainless steel probe is heat resistant.
- Tindif: Refer to the "Care and Maintenance" section for proper cleaning instructions. Do not immerse the entire unit in water.
- Sigurtà tal-batterija: Żomm il-batteriji fejn ma jintlaħqux mit-tfal. Armi l-batteriji użati b'mod responsabbli.
- Użu Intenzjonat: This thermometer is intended for measuring food temperatures. Do not use for purposes other than its intended use.
3. Kontenut tal-Pakkett
Il-pakkett tiegħek għandu jkun fih l-oġġetti li ġejjin:
- Taylor Digital Turbo Read Thermocouple Thermometer (Model 9867FDA)
- 1 x LR44 Battery (pre-installed or included separately)
4. Karatteristiċi tal-prodott
- Firxa Wiesgħa ta' Temperatura: Measures temperatures from -40°F to 450°F (-40°C to 232°C).
- Rapid Reading: Integrated thermocouple technology provides accurate readings within four seconds.
- Funzjoni ta' Żomm: Allows for continued temperature sampling without the display entering sleep mode, enabling you to record the last stable reading.
- Folding Probe: The stainless steel probe folds securely into the thermometer's handle for safe storage and portability.
- Display LCD ċar: Wirja diġitali faċli biex tinqara.
- Kostruzzjoni Durabbli: Made with ABS Plastic for the outer casing.
5. Konfigurazzjoni: Installazzjoni tal-Batterija
The thermometer requires one (1) LR44 battery. This battery is typically included and may be pre-installed. If the display does not turn on or is dim, replace the battery.
- Sib l-għatu tal-kompartiment tal-batterija fuq wara tat-termometru.
- Using a small screwdriver or coin, carefully open the battery compartment.
- Insert the LR44 battery, ensuring the correct polarity (+/-) as indicated inside the compartment.
- Ibdel l-għatu tal-kompartiment tal-batterija u waħħalha.
6. Istruzzjonijiet Operattivi
6.1. Tixgħil / Mitfi
To power on the thermometer, simply unfold the probe from its stored position. The display will illuminate. To power off, fold the probe back into the handle. The unit will automatically shut off after a period of inactivity to conserve battery life.
6.2. Taking a Temperature Reading
- Unfold the probe to turn on the thermometer.
- Insert the stainless steel probe into the thickest part of the food item, avoiding bone or gristle. Ensure the probe tip is at least 1/2 inch into the food for an accurate reading.
- Wait approximately four seconds for the temperature to stabilize on the LCD display.
- Neħħi s-sonda mill-ikel.
Image 6.2.1: Visual guide on how to insert the thermometer probe into various food types for accurate temperature readings.
6.3. Using the Hold Function
Agħfas il- ŻOMM button to freeze the current temperature reading on the display. This is useful when you need to view the temperature away from the heat source. Press the ŻOMM button again to release the reading and resume live temperature monitoring.
6.4. Switching Between Fahrenheit and Celsius
Agħfas il- °F/°C button to toggle the temperature display between Fahrenheit and Celsius.
6.5. Food Safety Temperature Guide
Always ensure food reaches safe internal temperatures to prevent foodborne illness. Refer to the guide below for recommended minimum internal temperatures.
Image 6.5.1: A visual chart detailing minimum internal food temperatures for various types of meat and poultry, along with a 'Danger Zone' indicator.
7. Kalibrazzjoni
For optimal accuracy, it is recommended to periodically calibrate your thermometer using the ice bath method. Your thermometer should read 32°F (0°C) in a properly prepared ice bath.
Ice Bath Method:
- Prepare Ice Bath: Fill a cup with crushed ice to the top. Crushed ice works best due to smaller ice crystals.
- Żid l-Ilma: Add cold water to the cup until it is about 1/2 inch below the top of the ice. The ice should not be floating off the bottom of the cup. If ice floats, pour off some water and add more ice.
- Insert Probe & Stir: Insert the thermometer probe into the center of the ice bath. Stir slowly. Allow time for the sensor to stabilize. Keep the probe tip away from the sides and bottom of the cup for best accuracy.
- Read & Calibrate: The thermometer should read 32.0°F (0.0°C). If your thermometer has a built-in wrench feature for calibration, adjust it as directed by the manufacturer's accuracy specifications. If the reading is within the specified tolerance, no adjustment is needed.
Image 7.1.1: Step-by-step visual instructions for calibrating a thermometer using the ice bath method.
Note: Many instant-read thermometers have a built-in wrench feature for calibration. Consult your specific model's instructions if available.
8. Kura u Manutenzjoni
- Tindif: Hand wash the stainless steel probe with warm, soapy water after each use. Wipe the thermometer body with a damp drapp. Do not immerse the entire thermometer in water or place it in a dishwasher.
- Ħażna: Fold the probe back into the handle for safe storage. Store the thermometer in a dry place at room temperature.
- Sostituzzjoni tal-batterija: Replace the LR44 battery when the display becomes dim or the unit fails to power on.
- Evita Temperaturi Estremi: Do not expose the thermometer to extreme hot or cold temperatures for prolonged periods, as this may affect accuracy or damage the unit.
9 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Id-displej huwa vojt jew mudlam. | Batterija baxxa jew mejta. | Replace the LR44 battery. Ensure correct polarity. |
| Qari mhux preċiż tat-temperatura. |
|
|
| Thermometer does not turn on when probe is unfolded. |
|
|
10. Speċifikazzjonijiet
| Numru tal-Mudell | 9867FDA |
| Firxa tat-Temperatura | -40°F sa 450°F (-40°C sa 232°C) |
| Ħin ta' Rispons | Madwar 4 sekonda |
| Sors tal-Enerġija | 1 x LR44 Battery |
| Tip ta 'Wiri | LCD |
| Materjal ta 'barra | Plastic ABS |
| Dimensjonijiet tal-Prodott | 5.71 x 1.18 x 1.18 pulzieri |
| Piż tal-oġġett | 3.84 uqija |
| Istruzzjonijiet tal-Kura | Hand Wash Only (probe); Wipe clean (body) |
| Manifattur | Lifetime Brands Inc. |
11. Garanzija u Appoġġ
Taylor products are manufactured to high-quality standards. For warranty information, technical support, or customer service inquiries, please refer to the contact information provided with your product packaging or visit the official Taylor websit.
Websit: www.taylorusa.com