Taylor 9867FDA

Taylor Digital Turbo Read Thermocouple Thermometer

Model: 9867FDA

1. Introduzzjoni

The Taylor Digital Turbo Read Thermocouple Thermometer with Folding Probe is designed for quick and accurate temperature measurements. Its compact design and rapid response time make it suitable for various culinary applications. This manual provides essential information for the proper use, care, and maintenance of your thermometer.

Taylor Digital Turbo Read Thermocouple Thermometer, Yellow

Image 1.1: The Taylor Digital Turbo Read Thermocouple Thermometer in yellow, featuring a digital display and a folding probe.

2. Informazzjoni dwar is-Sigurtà

3. Kontenut tal-Pakkett

Il-pakkett tiegħek għandu jkun fih l-oġġetti li ġejjin:

4. Karatteristiċi tal-prodott

5. Konfigurazzjoni: Installazzjoni tal-Batterija

The thermometer requires one (1) LR44 battery. This battery is typically included and may be pre-installed. If the display does not turn on or is dim, replace the battery.

  1. Sib l-għatu tal-kompartiment tal-batterija fuq wara tat-termometru.
  2. Using a small screwdriver or coin, carefully open the battery compartment.
  3. Insert the LR44 battery, ensuring the correct polarity (+/-) as indicated inside the compartment.
  4. Ibdel l-għatu tal-kompartiment tal-batterija u waħħalha.

6. Istruzzjonijiet Operattivi

6.1. Tixgħil / Mitfi

To power on the thermometer, simply unfold the probe from its stored position. The display will illuminate. To power off, fold the probe back into the handle. The unit will automatically shut off after a period of inactivity to conserve battery life.

6.2. Taking a Temperature Reading

  1. Unfold the probe to turn on the thermometer.
  2. Insert the stainless steel probe into the thickest part of the food item, avoiding bone or gristle. Ensure the probe tip is at least 1/2 inch into the food for an accurate reading.
  3. Wait approximately four seconds for the temperature to stabilize on the LCD display.
  4. Neħħi s-sonda mill-ikel.
Thermometer Tips for Accurate Readings

Image 6.2.1: Visual guide on how to insert the thermometer probe into various food types for accurate temperature readings.

6.3. Using the Hold Function

Agħfas il- ŻOMM button to freeze the current temperature reading on the display. This is useful when you need to view the temperature away from the heat source. Press the ŻOMM button again to release the reading and resume live temperature monitoring.

6.4. Switching Between Fahrenheit and Celsius

Agħfas il- °F/°C button to toggle the temperature display between Fahrenheit and Celsius.

6.5. Food Safety Temperature Guide

Always ensure food reaches safe internal temperatures to prevent foodborne illness. Refer to the guide below for recommended minimum internal temperatures.

Food Safety Temperature Guide

Image 6.5.1: A visual chart detailing minimum internal food temperatures for various types of meat and poultry, along with a 'Danger Zone' indicator.

7. Kalibrazzjoni

For optimal accuracy, it is recommended to periodically calibrate your thermometer using the ice bath method. Your thermometer should read 32°F (0°C) in a properly prepared ice bath.

Ice Bath Method:

  1. Prepare Ice Bath: Fill a cup with crushed ice to the top. Crushed ice works best due to smaller ice crystals.
  2. Żid l-Ilma: Add cold water to the cup until it is about 1/2 inch below the top of the ice. The ice should not be floating off the bottom of the cup. If ice floats, pour off some water and add more ice.
  3. Insert Probe & Stir: Insert the thermometer probe into the center of the ice bath. Stir slowly. Allow time for the sensor to stabilize. Keep the probe tip away from the sides and bottom of the cup for best accuracy.
  4. Read & Calibrate: The thermometer should read 32.0°F (0.0°C). If your thermometer has a built-in wrench feature for calibration, adjust it as directed by the manufacturer's accuracy specifications. If the reading is within the specified tolerance, no adjustment is needed.
Thermometer Calibration Tips using Ice Bath Method

Image 7.1.1: Step-by-step visual instructions for calibrating a thermometer using the ice bath method.

Note: Many instant-read thermometers have a built-in wrench feature for calibration. Consult your specific model's instructions if available.

8. Kura u Manutenzjoni

9 Issolvi l-problemi

Problema Kawża Possibbli Soluzzjoni
Id-displej huwa vojt jew mudlam. Batterija baxxa jew mejta. Replace the LR44 battery. Ensure correct polarity.
Qari mhux preċiż tat-temperatura.
  • Probe not inserted deep enough.
  • Probe tip touching bone or gristle.
  • Thermometer needs calibration.
  • Ensure probe is inserted into the thickest part of the food, at least 1/2 inch deep.
  • Reposition the probe to avoid bone/gristle.
  • Perform an ice bath calibration (see Section 7).
Thermometer does not turn on when probe is unfolded.
  • Ħruġ tal-batterija.
  • Probe not fully extended.
  • Check and replace battery if necessary.
  • Ensure the probe is fully extended until it clicks into place.

10. Speċifikazzjonijiet

Numru tal-Mudell 9867FDA
Firxa tat-Temperatura -40°F sa 450°F (-40°C sa 232°C)
Ħin ta' Rispons Madwar 4 sekonda
Sors tal-Enerġija 1 x LR44 Battery
Tip ta 'Wiri LCD
Materjal ta 'barra Plastic ABS
Dimensjonijiet tal-Prodott 5.71 x 1.18 x 1.18 pulzieri
Piż tal-oġġett 3.84 uqija
Istruzzjonijiet tal-Kura Hand Wash Only (probe); Wipe clean (body)
Manifattur Lifetime Brands Inc.

11. Garanzija u Appoġġ

Taylor products are manufactured to high-quality standards. For warranty information, technical support, or customer service inquiries, please refer to the contact information provided with your product packaging or visit the official Taylor websit.

Websit: www.taylorusa.com

Dokumenti Relatati - 9867FDA

Preview Termometru Diġitali tal-Laħam Taylor 9840: Gwida ta' Bidu Mgħaġġel u Temperaturi tat-Tisjir
Tgħallem kif tuża t-termometru diġitali tal-laħam Taylor 9840, inklużi l-firxiet tat-temperatura, il-linji gwida tat-tisjir tal-USDA, is-sostituzzjoni tal-batterija, u prekawzjonijiet importanti għal preparazzjoni preċiża tal-ikel. Il-karatteristiċi jinkludu display ċar u disinn durabbli.
Preview Taylor Digital Waterproof Thermometer User Guide
Instructions and information for the Taylor Digital Waterproof Thermometer, including how to use, battery information, cleaning, and warranty.
Preview Termometru tal-Laħam Wireless Taylor 5309295 li ma jgħaddix ilma minnu b'Kaxxa tal-Iċċarġjar Manwal tal-Istruzzjonijiet
Manwal ta' struzzjonijiet għat-Termometru tal-Laħam Wireless li ma jgħaddix ilma minnu Taylor 5309295 b'Kaxxa tal-Iċċarġjar, li jagħti dettalji dwar is-setup, l-użu, l-ispeċifikazzjonijiet tal-prodott, il-kura, il-prekawzjonijiet, il-konformità mal-FCC, u informazzjoni dwar il-garanzija.
Preview Manwal ta' Istruzzjoni tat-Termometru Wireless Taylor Five Star b'Pager Remot Plus Timer
Dan il-manwal tal-istruzzjonijiet jipprovdi gwida dettaljata għat-Termometru Wireless Taylor Five Star b'Pager Remot flimkien ma' Timer (mudelli 1479, 1479-21, 532, 532-77). Tgħallem is-setup, it-tħaddim, il-programmazzjoni, il-funzjonijiet tat-tajmer, is-settings tal-arloġġ, il-kura, il-prekawzjonijiet, u s-soluzzjoni tal-problemi għat-termometru diġitali tat-tisjir tiegħek.
Preview Manwal tal-Utent tat-Termometru tas-Sonda Diġitali li Jintewa Taylor 9867B
Manwal tal-utent u struzzjonijiet għat-Termometru tas-Sonda Diġitali li Jintewa Taylor 9867B, li jkopru t-tħaddim, il-kalibrazzjoni, il-kura, is-soluzzjoni tal-problemi, l-ispeċifikazzjonijiet, u l-garanzija.
Preview Termometru Bluetooth mingħajr fili Taylor 5309295 - Karatteristiċi u Użu
Informazzjoni dettaljata dwar it-Termometru Bluetooth Wireless Taylor 5309295, inklużi l-ispeċifikazzjonijiet, il-karatteristiċi, l-użi multipli tat-tisjir, il-faċilità tat-tindif, u l-istruzzjonijiet għat-tqabbil tas-sistema. Traċċa t-temperaturi mingħajr fili fil-fran, fil-grills, u fl-affumikaturi b'dan l-apparat IPX7 li ma jgħaddix ilma minnu u li jista' jiġi ċċarġjat.