1. Introduzzjoni
Thank you for choosing the Taylor 6092N Instant Read Pocket Bimetal Thermometer. This precision instrument is designed for quick and accurate temperature measurements in various applications, particularly in culinary and laboratory settings. Its durable construction and clear analog display make it a reliable tool for ensuring proper temperatures.
2. Informazzjoni dwar is-Sigurtà
Please read and understand all safety instructions before using this thermometer. Improper use can lead to inaccurate readings or damage to the device.
- This thermometer is not intended for medical or internal body temperature measurement.
- Il-ponta tas-sonda hija qawwija. Immaniġġja b'attenzjoni biex tevita korriment.
- Do not expose the thermometer to temperatures exceeding its maximum rated temperature of 220°F (104°C), as this may damage the internal mechanism.
- Żomm fejn ma jintlaħaqx mit-tfal.
- Avoid dropping the thermometer, as impact can affect its accuracy.
3. Setup
3.1 Disimballaġġ
- Carefully remove the thermometer and its protective sheath from the packaging.
- Inspect the thermometer for any visible damage. If damaged, do not use and contact customer support.
3.2 L-Ewwel Użu
Before first use, and after each use, clean the thermometer probe thoroughly.
- Remove the protective sheath.
- Wipe the stainless steel probe with a damp drapp u sapun ħafif.
- Rinse the probe with clean water and dry thoroughly. Do not immerse the entire thermometer in water.

This image displays the Taylor 6092N thermometer, showing its stainless steel stem and dial, alongside its blue protective plastic sheath. The sheath is designed to protect the thermometer when not in use and can also serve as a handle extension.
4. Istruzzjonijiet Operattivi
4.1 Taking a Temperature Reading
- Ensure the thermometer probe is clean.
- Insert the stainless steel probe into the center of the item being measured. For liquids, stir gently to ensure even temperature distribution.
- For accurate readings, the probe should be inserted at least 2 inches (5 cm) into the substance, or past the dimple on the stem if present.
- Wait for the dial to stabilize, which typically takes a few seconds due to its fast reading system. The response time is approximately 500 milliseconds.
- Read the temperature indicated on the analog dial.
- Remove the thermometer and clean the probe immediately after use.
4.2 Calibration (Optional)
While factory calibrated, bimetal thermometers can sometimes drift over time. If you suspect inaccuracy, you can check and adjust the calibration. This model may feature a calibration nut located under the dial or on the back of the dial face.
- Prepare an ice bath: Fill a glass with crushed ice and add cold water until the glass is full. Stir well and let it sit for a few minutes.
- Insert the thermometer probe into the ice bath, ensuring the sensing area is fully submerged and not touching the bottom or sides of the glass.
- Wait for the reading to stabilize (typically 30 seconds to 1 minute). A properly calibrated thermometer should read 32°F (0°C).
- If the reading is not 32°F (0°C), locate the calibration nut (often a hexagonal nut below the dial or a small screw on the back).
- Using a small wrench or pliers, carefully turn the calibration nut until the pointer reads 32°F (0°C) while the probe is still in the ice bath.
- Remove, clean, and store the thermometer.
5. Manutenzjoni u Kura
5.1 Tindif
To maintain accuracy and hygiene, clean the thermometer after each use. The product care instructions specify to Imsaħ Nadif.
- Wipe the stainless steel probe with a damp drapp u deterġent ħafif.
- Rinse the probe thoroughly with clean water.
- Dry completely before storing.
- Do not use abrasive cleaners or immerse the entire thermometer in water.
5.2 Ħażna
Store the thermometer in its protective sheath when not in use. Keep it in a clean, dry place away from extreme temperatures and direct sunlight. Proper storage helps protect the probe and maintain the thermometer's accuracy.
6 Issolvi l-problemi
| Ħruġ | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Qari mhux eżatt | Improper insertion depth; Needs calibration; Damaged sensor. | Ensure probe is inserted past the sensing area (at least 2 inches). Perform calibration as described in Section 4.2. If issues persist, the thermometer may be damaged. |
| Slow Response Time | Insufficient immersion; Item not stirred (for liquids). | Ensure adequate probe immersion. Stir liquids to distribute heat evenly. Allow sufficient time for the reading to stabilize. |
| Dial is Stuck or Jumps | Physical damage; Extreme temperature exposure. | Inspect for physical damage. Avoid exposing the thermometer to temperatures outside its specified range. If damaged, replacement may be necessary. |
7. Speċifikazzjonijiet
| Karatteristika | Dettall |
|---|---|
| Brand | Taylor |
| Numru tal-Mudell | 6092N (077784609217) |
| Firxa tat-Temperatura | 0°F sa 220°F (-18°C sa 104°C) |
| Tip ta 'Wiri | Dial Analog |
| Materjal ta 'barra | Metall |
| Ħin ta' Rispons | 500 Milliseconds (Fast Reading System) |
| Istruzzjonijiet għall-Kura tal-Prodott | Imsaħ Nadif |
| Dimensjonijiet tal-Pakkett | 5.59 x 0.91 x 0.91 pulzieri (14.2 x 2.3 x 2.3 ċm) |
| Piż tal-Pakkett | 0.01-il uqija (0.018 kg) |
| Pajjiż ta' Oriġini | Iċ-Ċina |
| Manifattur | COLE-PARMER |
8. Garanzija u Appoġġ
This Taylor thermometer is manufactured to high-quality standards. For information regarding warranty coverage, limitations, and how to obtain service, please refer to the warranty card included with your purchase or visit the official Taylor websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri.
For technical support or inquiries, please contact Taylor customer service through their official channels. Contact information can typically be found on the manufacturer's webis-sit jew l-imballaġġ tal-prodott.