Leviton 5266-B

Leviton 15 Amp, 125 Volt, Straight Blade, Industrial Grade Grounding Plug (Model 5266-B) Instruction Manual

Mudell: 5266-B

Introduzzjoni

Dan il-manwal jipprovdi struzzjonijiet dettaljati għall-installazzjoni u l-użu sikur u xieraq tal-Leviton 15 Amp, 125 Volt, Straight Blade, Industrial Grade Grounding Plug, Model 5266-B. This device is designed for reliable performance in demanding environments.

Leviton 5266-B Industrial Grade Grounding Plug

Image: Leviton 15 Amp, 125 Volt, Straight Blade, Industrial Grade Grounding Plug (Model 5266-B).

Informazzjoni Importanti dwar is-Sigurtà

WARNING: Shock Hazard. To avoid risk of serious injury or death, turn power off at the circuit breaker before wiring any electrical device.

Setup u Installazzjoni

This section details the steps required to properly wire the Leviton 5266-B plug to an electrical cable.

Għodod Meħtieġa:

Proċedura tal-Wiring:

  1. Ipprepara l-Plagg:

    Using a Phillips head screwdriver, loosen the quick-release screws on the faceplate of the plug. Carefully remove the faceplate from the body housing.

  2. Ipprepara l-Cable:

    Loosen the two strain relief screws on the plug's body housing. Feed the electrical cable through the strain relief and into the body housing. Strip the cord jacket according to the diagram provided in the instruction sheet (typically 1.5 inches). Remove the cord jacket to expose the individual wires.

  3. Trim the Ground Wire:

    The green (ground) wire needs to be approximately 1 inch long. Use wire strippers to cut the green wire to the appropriate length.

  4. Strip Individual Wires:

    Strip approximately 5/8 inch of insulation from all individual wires (green, white, and any hot wires). Twist the strands of each wire tightly to prevent fraying.

  5. Connect the Ground Wire:

    Loosen the green ground screw located in the center of the faceplate. Insert the stripped green (ground) wire into the wire well of the green terminal. Tighten the terminal screw securely.

  6. Connect the Neutral Wire:

    Loosen the silver terminal screw. Insert the stripped white (neutral) wire into the wire well of the silver terminal. Tighten the terminal screw securely.

  7. Connect Hot Wires:

    Loosen the brass terminal screws. Insert the remaining stripped wires (hot wires, typically black or red) into the wire wells of the brass terminals. Tighten the terminal screws securely.

  8. Reassemble the Plug:

    Align the channel guide on the body housing with the faceplate. Slide the faceplate into the body housing. Using a Phillips head screwdriver, tighten the quick-release screws on the faceplate to secure it to the body housing.

  9. Tighten Strain Relief:

    Tighten both screws on the strain relief to secure the cable and prevent tension on the internal wiring connections.

  10. Note for Larger Wires:

    If your cable is larger than the groove on the strain relief, a section of the strain relief can be removed to accommodate larger wire gauges.

Vidjo ta 'installazzjoni:

For a visual guide on wiring the Leviton Black and White Plug and Connector, please refer to the video below:

Video: Instructions on how to wire a Leviton Black and White Plug and Connector. This video demonstrates the step-by-step process of disassembling the plug, preparing the cable, connecting the ground, neutral, and hot wires, and reassembling the device, including tightening the strain relief.

Istruzzjonijiet Operattivi

Once properly wired and assembled, the Leviton 5266-B plug is ready for use. Insert the plug into a compatible 125V, 15 Amp receptacle. Ensure a secure connection. This industrial-grade plug is designed for demanding applications, providing reliable power transmission.

Manutenzjoni

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Ebda enerġija għall-apparat konnessLoose wire connection; tripped circuit breaker; faulty receptacle.Check all wire connections inside the plug. Reset the circuit breaker. Test the receptacle with another known working device.
Plug feels hot during useOverload; loose connection; damaged wire.Reduce load on the circuit. Check for loose connections. Inspect wires for damage. Discontinue use if overheating persists.
Cable pulls out of plugLoose strain relief.Tighten the strain relief screws securely.

Speċifikazzjonijiet

Garanzija u Appoġġ

This Leviton product is covered by a manufacturer's warranty. For specific warranty details, claims, or technical support, please refer to the official Leviton website or contact their customer service directly. Keep your purchase receipt for warranty purposes.

Għal aktar informazzjoni, żur il- Ħanut Leviton fuq Amazon.

Dokumenti Relatati - 5266-B

Preview Gwida għall-Installazzjoni u l-Ittestjar tar-Reċettaklu Leviton GFCI
Gwida komprensiva dwar kif tinstalla u tittestja Reċipjent Leviton SmartLock Pro GFCI, inklużi struzzjonijiet dwar il-wajers, prekawzjonijiet ta' sigurtà, u pariri dwar kif issolvi l-problemi.
Preview Leviton EV40P EV Serje 40 AMP Manwal tal-Installazzjoni tal-Ċarġer Plug-In
Manwal tal-installazzjoni għal-Leviton EV40P EV Series 40 AMP Ċarġer tal-Vetturi Elettriċi Plug-In. Jinkludi twissijiet ta' sigurtà, speċifikazzjonijiet, passi ta' installazzjoni, proċeduri operattivi, użu tal-kard RFID, messaġġi ta' żball, manutenzjoni, u informazzjoni dwar il-garanzija.
Preview Manwal tal-Installazzjoni u t-Tħaddim tas-Sokit GFCI ta' Leviton bil-Portijiet USB
Gwida komprensiva għall-installazzjoni u t-tħaddim ta' Leviton GFCI Outlets b'Portijiet USB, inklużi struzzjonijiet dwar il-wajers, twissijiet ta' sigurtà, proċeduri ta' ttestjar, u informazzjoni dwar il-garanzija.
Preview Installazzjoni u Ittestjar ta' Leviton Smart GFCI Outlet: Gwida Komprensiva
Istruzzjonijiet pass pass għall-installazzjoni u l-ittestjar tas-sokits Leviton Smart GFCI (mudelli D2GF1, D2GF2). Tgħallem dwar il-funzjonalità GFCI, il-wajers, is-soluzzjoni tal-problemi, u l-prekawzjonijiet ta' sigurtà.
Preview Istruzzjonijiet għall-Installazzjoni tal-Għeluq taċ-Ċentru tat-Tagħbija ta' Leviton
Istruzzjonijiet dettaljati għall-installazzjoni tal-Leviton Load Center Enclosures, mudelli LP2xx, LP3xx, LP4xx, u LP6xx. Tkopri s-sigurtà, it-tneħħija tal-knockout, l-immuntar, il-wajers, l-installazzjoni tas-circuit breaker tal-fergħa, u t-twaħħil tal-għatu.
Preview Katalogu Leviton L-100: Apparati tal-Wajers u Kontrolli tad-Dawl għall-Kostruzzjoni u l-Manutenzjoni
Esplora l-katalgu komprensiv ta' Leviton L-100, li fih għażla vasta ta' apparati tal-wajers ta' kwalità għolja, kontrolli tad-dawl, u soluzzjonijiet elettriċi għal applikazzjonijiet industrijali, kummerċjali, u residenzjali. Skopri s-seklu ta' innovazzjoni u impenn ta' Leviton għall-kwalità.