CAS BW-150DB

Manwal tal-Utent tal-Iskala tal-Bank CAS BW-150

Model: BW-150DB

Marka: CAS

Introduzzjoni

This manual provides essential information for the proper setup, operation, and maintenance of your CAS BW-150 Bench Scale. Please read this manual thoroughly before using the scale to ensure safe and accurate performance. The CAS BW-150 is a robust bench scale designed for various industrial and commercial weighing applications, offering a high capacity and precise readability.

Prodott Overview

CAS BW-150 Bench Scale with stainless steel platform and digital display on a pole

Figura 1: The CAS BW-150 Bench Scale, featuring a durable stainless steel weighing platform and an adjustable digital display unit mounted on a sturdy pole. This design allows for clear visibility of readings during operation.

The CAS BW-150 Bench Scale is engineered for accuracy and durability. It features a large weighing platform and a clear LCD display, making it suitable for environments requiring reliable weight measurements up to 300 pounds. Its design emphasizes ease of use and long-term performance.

Setup Istruzzjonijiet

  1. Spakkjar: Carefully remove all components from the packaging. Verify that all parts are present: weighing platform, display unit, pole, power adapter, and this user manual.
  2. Assemblea:
    • Attach the pole to the weighing platform base. Ensure it is securely fastened.
    • Mount the display unit onto the top of the pole. Secure it firmly to prevent wobbling.
    • Connect the display unit cable to the appropriate port on the weighing platform.
  3. Pjazzament: Place the assembled scale on a firm, level, and stable surface. Avoid locations with excessive vibrations, drafts, or direct sunlight, which can affect measurement accuracy.
  4. Konnessjoni tal-Enerġija: Connect the power adapter to the display unit and then plug it into a suitable electrical outlet. Ensure the power supply matches the scale's requirements.
  5. Qawwa Inizjali Mixgħula: Agħfas il- ON/OFF button to power on the scale. The display should perform a self-test and then show "0.0" or "0.00".

Istruzzjonijiet Operattivi

  1. Power On/Off: Agħfas il- ON/OFF button to turn the scale on or off.
  2. Użin:
    • Ensure the display reads "0.0" before placing an item on the platform. If not, press the ŻERO buttuna.
    • Gently place the item to be weighed in the center of the weighing platform.
    • Wait for the reading to stabilize. The stable weight will be displayed on the LCD.
  3. Funzjoni tat-tara: To weigh an item in a container, first place the empty container on the platform. Press the TARE button. The display will reset to "0.0". Then, place the item inside the container. The display will show the net weight of the item.
  4. Konverżjoni tal-Unità: If your model supports multiple units, press the UNITÀ button to cycle through available weighing units (e.g., pounds, kilograms). The BW-150DB primarily operates in pounds with 0.1 lb readability.

Manutenzjoni

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
L-iskala ma tixgħel.No power, faulty power adapter, or internal issue.Check power connection and outlet. Ensure power adapter is functioning. If problem persists, contact support.
Qari mhux preċiż jew instabbli.Scale not level, unstable surface, drafts, or damaged load cell.Ensure scale is on a firm, level surface. Eliminate drafts. Recalibrate if necessary or contact service.
Display shows "OVERLOAD" or "Err".Weight exceeds maximum capacity (300 lbs) or sudden impact.Remove excess weight. Avoid dropping items on the platform.
Scale turns off unexpectedly.Auto-off feature activated, low power, or internal fault.Check power connection. Some scales have an auto-off feature to save power; consult the full manual for settings. If persistent, contact support.

Speċifikazzjonijiet

Garanzija u Appoġġ

For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official CAS websit. Il-kopertura tal-garanzija tipikament tindirizza difetti fil-manifattura.

If you require technical assistance, service, or have questions not covered in this manual, please contact CAS customer support. Contact information can usually be found on the manufacturer's official webis-sit jew fuq l-imballaġġ tal-prodott.

CAS Official Websit: Visit CAS Store on Amazon (għal informazzjoni ġenerali u firxa ta' prodotti)

Dokumenti Relatati - BW-150DB

Preview CAS EB Series Retail Bench Scale Owner's Manual
Comprehensive owner's manual for the CAS EB Series Retail Bench Scale, detailing setup, operations, programming, sales transactions, and specifications for accurate retail weighing.
Preview Manwal tas-Sid tal-Iskala tal-Komputazzjoni tal-Prezz tas-Serje CAS ER JR
Manwal komprensiv tas-sid għall-Iskala tal-Komputazzjoni tal-Prezzijiet tas-Serje CAS ER JR, li jiddeskrivi l-operazzjoni, is-setup, il-karatteristiċi, l-immaniġġjar tal-iżbalji, u l-ispeċifikazzjonijiet tekniċi għal ambjenti tal-bejgħ bl-imnut.
Preview Manwal tas-Sid tal-Iskala tal-Komputazzjoni tal-Prezzijiet tas-Serje CAS PR-II
Manwal komprensiv tas-sid għall-iskala tal-komputazzjoni tal-prezzijiet tas-Serje CAS PR-II, li jkopri l-installazzjoni, it-tħaddim, il-manutenzjoni, l-ispeċifikazzjonijiet, u d-dettalji tal-interfaċċja.
Preview Gwida Mgħaġġla għall-Iskala tal-Istampar ta' Biljetti u Tikketti CAS CL-5500
Gwida rapida dwar kif tħaddem l-Iskala tal-Istampar ta' Biljetti u Tikketti CAS CL-5500, li tkopri l-operazzjonijiet tal-bejgħ u t-tikkettar.
Preview Gwida Rapida għall-Iskala tal-Istampar tat-Tikketti CAS CN1
Gwida rapida għall-operat tal-iskala tal-istampar tat-tikketti CAS CN1, li tkopri l-operazzjonijiet tat-tikkettar għall-użin ta' oġġetti u l-għadd ta' oġġetti.
Preview Manwal tas-Sid tal-Iskala tal-Krejn CAS IE SERIES
Manwal uffiċjali tas-sid għall-iskala tal-krejn CAS IE SERIES. Jipprovdi struzzjonijiet dettaljati dwar is-sigurtà, it-tħaddim, l-ispeċifikazzjonijiet, is-soluzzjoni tal-problemi, u l-funzjonijiet tal-kontrollur remot għal applikazzjonijiet ta' użin industrijali.