APC SMT750

APC Smart-UPS 750VA (SMT750) Instruction Manual

Brand: APC | Model: SMT750

1. Introduzzjoni u Fuqview

The APC Smart-UPS 750VA (SMT750) is an Uninterruptible Power Supply (UPS) designed to provide reliable battery backup and surge protection for your electronic devices. Featuring pure sine wave output, it ensures compatibility with active PFC power supplies and sensitive electronics. This 120V unit offers 750VA / 500W capacity, safeguarding your equipment against power disruptions and ensuring continuous operation during power outages.

2. Karatteristiċi tal-prodott

  • 750VA / 500W Battery Backup: Provides essential power during outages to protect connected equipment.
  • Ħruġ ta' Mewġ Sinus Pur: Ensures the highest degree of compatibility with active Power Factor Correction (PFC) power supplies and sensitive electronics, delivering clean and stable power.
  • 6 Battery Backup and Surge Protector Outlets: Offers comprehensive protection for multiple devices.
  • Smart UPS with LCD Display: Provides real-time status updates and configuration options directly on the unit.
  • Network-Grade Power Conditioning: Protects from damaging surges and disruptive noise.
  • Solid State Automatic Voltage Regolament (AVR): Boosts low input voltage and trims high voltage without relying on battery operation, preserving battery life.
  • Network Manageable: Connectivity via serial, USB, or optional Ethernet for remote monitoring and management.
  • Line Interactive Topology: Efficient and reliable power protection.
  • Note: This SMT750 model is not sold in Vermont.

3. Istruzzjonijiet ta' Setup

Follow these steps to set up your APC Smart-UPS SMT750 for optimal performance.

  1. Iftaħ il-pakkett tal-UPS: Neħħi l-UPS u l-aċċessorji kollha mill-imballaġġ bir-reqqa. Spezzjona għal kwalunkwe ħsara waqt it-tbaħħir.
  2. Qabbad il-batterija: The UPS is shipped with the battery disconnected for safety. Locate the battery connector on the rear panel. Remove the protective cap from the battery connector. Connect the battery cable to the battery connector. Ensure a secure connection.
  3. Connect Equipment to UPS Outlets: Plug your critical electronic devices (computers, monitors, network equipment) into the 'Battery Backup + Surge' outlets. For devices that only require surge protection (e.g., printers, scanners), use the 'Surge Only' outlets.
  4. Qabbad mal-Enerġija tal-Utilità: Plug the UPS power cord into a grounded 120V AC wall outlet.
  5. Ħlas Inizjali: Allow the UPS to charge for at least 24 hours before initial use to ensure maximum runtime capacity. The LCD display will indicate the battery charge level.
  6. Ixgħel l-UPS: Press the power button on the front panel to turn on the UPS. The LCD display will illuminate, showing the current status.
Rear panel of APC Smart-UPS SMT750 showing ports
Figura 1: Konnessjonijiet tal-Panel ta' Wara. This image displays the rear panel of the APC Smart-UPS SMT750, highlighting its various connection ports and features. Key components visible include the USB Port, UPS Monitoring Port, multiple output receptacles, input power connection, overload protector, and the battery connector with its protective cap.

4. Istruzzjonijiet Operattivi

Once set up, your APC Smart-UPS SMT750 operates largely automatically. The LCD display provides crucial information and allows for basic configuration.

  • Operazzjoni normali: When utility power is present, the UPS charges its battery and provides surge-protected power to connected devices. The LCD will show 'On Line' status.
  • Operazzjoni tal-batterija: Waqt qawwa outage, the UPS automatically switches to battery power, providing uninterrupted power to connected devices. An audible alarm may sound, and the LCD will indicate 'On Battery' status and estimated runtime.
  • Display LCD: Use the display buttons to cycle through various information screens, including input/output voltage, tagħbija perċentwalitage, il-livell tal-ċarġ tal-batterija, u l-ħin stmat tal-funzjonament.
  • Ġestjoni tan-Netwerk: For advanced monitoring and management, connect the UPS to your network via the USB or serial port, or an optional Ethernet card. Install the PowerChute software (available from APC) on your computer for detailed control and graceful shutdown capabilities.
  • Protezzjoni ta' tagħbija żejda: If the UPS is overloaded, it will sound an alarm and may shut down. Reduce the load by unplugging non-essential devices and press the 'Overload Protector' button on the rear panel to reset.

5. Manutenzjoni

Regular maintenance ensures the longevity and reliability of your UPS.

  • Sostituzzjoni tal-batterija: The internal 12V lead-acid battery has a finite lifespan. When the battery needs replacement, the UPS will indicate this on the LCD. Refer to the APC website or contact support for compatible replacement battery cartridges (RBCs). Battery replacement is typically user-serviceable.
  • Tindif: Keep the UPS clean and free of dust. Use a dry cloth to wipe down the exterior. Ensure ventilation openings are not obstructed.
  • Kundizzjonijiet Ambjentali: Operate the UPS within recommended temperature and humidity ranges to maximize battery life and overall performance.

6 Issolvi l-problemi

This section addresses common issues you might encounter with your UPS.

  • L-UPS Mhux Mixgħul: Ensure the battery is properly connected and the UPS is plugged into a live wall outlet. Check the circuit breaker on the rear panel.
  • Żmien Qasir: The battery may not be fully charged, or it may be nearing the end of its service life. Allow for a full 24-hour charge or consider battery replacement.
  • Ħoss Kostanti: Dan ġeneralment jindika li l-UPS qed jaħdem bil-batterija minħabba qtugħ tal-enerġija tal-utilità.tage or a low battery condition. Check your utility power.
  • Indikazzjoni ta' tagħbija żejda: If the UPS displays an overload warning, disconnect non-essential equipment from the battery backup outlets and press the overload protector reset button.
  • L-ebda enerġija għall-iżbokkijiet: Verify the UPS is turned on and receiving utility power. Check if the outlets are 'Battery Backup + Surge' or 'Surge Only'.

7. Speċifikazzjonijiet

SpeċifikazzjoniValur
Dimensjonijiet tal-Prodott19.69 x 10.63 x 11.42 pulzieri
Piż tal-oġġett29 liri
ManifatturAPC
Numru tal-Mudell tal-OġġettSMT750
Batteriji1 batterija 12V meħtieġa (inkluża)
Voltage120 Volts
KulurAħdar
Data L-Ewwel Disponibbli27 ta’ Awwissu, 2009

8. Garanzija u Appoġġ

For detailed warranty information, product registration, and technical support, please visit the official APC by Schneider Electric webis-sit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom. Żomm l-irċevuta tax-xiri tiegħek għal talbiet ta’ garanzija.

Dokumenti Relatati - SMT750

Preview Manwal tal-Utent tas-Serje APC Back-UPS BX: Installazzjoni, Tħaddim, u Soluzzjoni ta' Problemi
Manwal komprensiv għall-utent għall-APC Back-UPS BX Series (500VA sa 2200VA) minn Schneider Electric, li jkopri struzzjonijiet ta' sigurtà, deskrizzjoni tal-prodott, karatteristiċi operattivi, installazzjoni, issolvi l-problemi, servizz, u informazzjoni dwar il-garanzija.
Preview Manwal tal-Utent tal-APC Back-UPS BN600G
Manwal tal-utent għall-APC Back-UPS BN600G Uninterruptible Power Supply (UPS), li jipprovdi informazzjoni dwar is-sigurtà, speċifikazzjonijiet, installazzjoni, tħaddim, issolvi l-problemi, u dettalji dwar il-garanzija.
Preview Manwal tal-Utent tas-Serje APC Back-UPS BX: Sigurtà, Tħaddim, u Speċifikazzjonijiet
Manwal tal-utent għall-APC Back-UPS BX Series (500VA-2200VA) minn Schneider Electric. Jipprovdi informazzjoni dettaljata dwar struzzjonijiet ta' sigurtà, karatteristiċi tal-prodott, installazzjoni, modi operattivi, speċifikazzjonijiet, indikaturi tal-istatus, issolvi l-problemi, servizz, u garanzija.
Preview Gwida għall-Installazzjoni u t-Tħaddim tal-APC Back-UPS Pro 900
Din il-gwida tipprovdi struzzjonijiet għall-installazzjoni u t-tħaddim tal-APC Back-UPS Pro 900, inkluż is-setup, l-installazzjoni tas-softwer, il-konnessjoni tat-tagħmir, karatteristiċi operattivi bħall-iffrankar tal-enerġija u l-modi tal-wiri, is-soluzzjoni tal-problemi, u l-ispeċifikazzjonijiet.
Preview APC Easy Back UPS BX Series User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for APC Easy Back UPS BX Series (750VA, 950VA, 1200VA, 1600VA, 2200VA) covering safety information, product description, installation, operational features, specifications, status indicators, troubleshooting, service, and warranty.
Preview Manwal tal-Installazzjoni u t-Tħaddim tal-APC Smart-UPS RT
Dan il-manwal jipprovdi struzzjonijiet komprensivi għall-installazzjoni, it-tħaddim, u l-manutenzjoni tas-serje APC Smart-UPS RT, inklużi l-mudelli SURT1000 u SURT2000. Ikopri prekawzjonijiet ta' sigurtà, proċeduri ta' setup, indikaturi operattivi, issolvi l-problemi, u informazzjoni dwar il-garanzija għal dawn il-provvisti tal-enerġija mingħajr interruzzjoni.