1. Prodott Aktarview
The Victor 0323-0261 12-MFA Professional Heating Nozzle is engineered for precision heating applications. It is designed for use with the HD 310C Torch Handle and features a multi-flame heating head, making it suitable for various tasks including heat treating, straightening, and priming. This nozzle operates with Acetylene and Hydrogen as fuel gases.

Image: The Victor 0323-0261 12-MFA Professional Heating Nozzle, a copper-colored, angled nozzle with a brass fitting at one end, designed for heating applications.
2. Informazzjoni dwar is-Sigurtà
Always prioritize safety when operating heating equipment. Failure to follow safety guidelines can result in serious injury or property damage.
- Tagħmir Protettiv Personali (PPE): Always wear appropriate PPE, including welding gloves, safety glasses or a face shield, and protective clothing, to guard against heat, sparks, and UV radiation.
- Ventilazzjoni: Ensure adequate ventilation in the work area to prevent the accumulation of hazardous fumes and gases. Work in a well-ventilated space or use local exhaust ventilation.
- Immaniġġjar taċ-Ċilindri tal-Gass: Handle gas cylinders with care. Secure them upright to prevent tipping. Ensure regulators and hoses are in good condition and properly connected.
- Sejbien ta' tnixxija: Before each use, check all connections for leaks using a suitable leak detection solution. Never use a flame to check for leaks.
- Materjali li jaqbdu: Keep flammable materials away from the work area. Be aware of your surroundings and potential fire hazards.
- Kompatibilità tal-Manku tat-Torċa: This nozzle is designed for use with the HD 310C Torch Handle. Ensure compatibility before attachment.
- Issettjar tal-Pressjoni: Adhere strictly to the recommended oxygen and fuel gas pressure settings to prevent equipment damage or unsafe operation.
- Proċeduri ta 'Emerġenza: Know the location of fire extinguishers and emergency shut-off valves for gas supplies.
3. Setup
- Spezzjona Tagħmir: Before setup, visually inspect the heating nozzle, torch handle (HD 310C), hoses, and regulators for any signs of damage, wear, or blockages.
- Qabbad iż-Żennuna: Carefully thread the Victor 0323-0261 12-MFA heating nozzle onto the HD 310C Torch Handle. Hand-tighten first, then use a wrench to secure it firmly, but do not overtighten.
- Qabbad Manek: Ensure the oxygen and fuel gas hoses are securely connected to their respective regulators and the torch handle.
- Purge Hoses: Briefly open the cylinder valves to purge any air or contaminants from the hoses before connecting to the torch.
- Iċċekkja għal Tnixxijiet: Apply a leak detection solution to all connections (nozzle to torch, hoses to torch, hoses to regulators, regulators to cylinders). Bubbles indicate a leak. Tighten connections or replace faulty components if leaks are detected.
- Set Pressures: With the torch valves closed, slowly open the oxygen and fuel gas cylinder valves. Adjust the regulators to the recommended operating pressures:
- Oxygen Pressure: 50-60 PSIG
- Fuel Pressure (Acetylene/Hydrogen): 12-15 PSIG
4. Istruzzjonijiet Operattivi
This multi-flame heating nozzle is designed for heat treating, straightening, and priming applications.
- Tqabbid:
- Open the fuel gas valve on the torch handle slightly.
- Use a spark lighter to ignite the gas at the nozzle tip. Never use matches or a cigarette lighter.
- Slowly open the oxygen valve on the torch handle until the desired flame is achieved. Adjust both valves for a neutral flame, characterized by a clear, well-defined inner cone.
- Applikazzjoni:
- Direct the flame towards the workpiece, maintaining a consistent distance for even heat distribution.
- For heat treating, apply heat uniformly to the area requiring treatment.
- For straightening, apply heat to the convex side of the bend to cause expansion and subsequent contraction upon cooling.
- For priming, heat the surface to remove moisture and contaminants, preparing it for coating.
- Itfi:
- First, close the oxygen valve on the torch handle.
- Then, close the fuel gas valve on the torch handle.
- Close the cylinder valves for both oxygen and fuel gas.
- Bleed the pressure from the regulators by opening the torch valves briefly until the gauge readings drop to zero. Close the torch valves.
Gas Consumption Rates:
- Oxygen Consumption: 66-165 SCFH
- Fuel Consumption (Acetylene/Hydrogen): 60-150 SCFH
5. Manutenzjoni
Regular maintenance ensures the longevity and safe operation of your heating nozzle.
- Tindif taż-żennuna: Periodically clean the nozzle tip to remove any carbon buildup or debris that may obstruct the gas flow. Use appropriate tip cleaners designed for heating nozzles. Do not use abrasive materials that could damage the tip.
- Spezzjoni: Regularly inspect the nozzle for any signs of damage, such as cracks, dents, or excessive wear. Check the brass fitting for secure attachment and integrity.
- Hose and Regulator Check: Inspect hoses for cuts, abrasions, or leaks. Ensure regulators are functioning correctly and gauges are accurate. Replace any damaged components immediately.
- Ħażna: Store the heating nozzle and associated equipment in a clean, dry place, protected from extreme temperatures and physical damage. Disconnect from gas supplies when not in use for extended periods.
6 Issolvi l-problemi
This section addresses common issues you might encounter with your heating nozzle.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| No flame or weak flame |
|
|
| Inconsistent or sputtering flame |
|
|
| Gas leaks detected |
|
|
7. Speċifikazzjonijiet
| Attribut | Dettall |
|---|---|
| Numru tal-Mudell | 0323-0261 (12-MFA) |
| Manifattur | Victor |
| Brand | ESAB |
| Kompatibilità | HD 310C Torch Handle |
| Applikazzjonijiet | Heat treating, straightening, priming |
| Fuel Gas Usage | Acetylene and Hydrogen |
| Tul Ġenerali | 17.5 pulzieri |
| Oxygen Pressure (PSIG) | 50-60 |
| Fuel Pressure (PSIG) | 12-15 |
| Oxygen Consumption (SCFH) | 66-165 |
| Fuel Consumption (SCFH) | 60-150 |
| Dimensjonijiet tal-Prodott | 18 x 3 x 3 pulzieri |
| Piż tal-oġġett | 0.64 uqija |
8. Garanzija u Appoġġ
For specific warranty information regarding your Victor 0323-0261 12-MFA Professional Heating Nozzle, please refer to the documentation provided with your purchase or visit the official ESAB/Victor website. Warranty terms and conditions typically cover manufacturing defects and material flaws under normal use.
For technical support, spare parts, or service inquiries, please contact ESAB customer service or an authorized Victor dealer. You can often find contact information and support resources on the official ESAB websit: www.esab.com