Introduzzjoni
The CDN Dual Sensing Programmable Probe Thermometer and Timer (Model DSP1) is designed to accurately measure both the internal temperature of food and the ambient temperature of your oven or grill. This versatile tool assists in achieving precise cooking results and ensuring food safety. It features a durable stainless steel probe and cable, a clear digital display, and programmable alarms.

Immaġni: Quddiem view of the CDN DSP1 thermometer with probe attached, displaying oven and food temperatures.
Karatteristiċi Ewlenin
- Dual Sensing Probe: Measures both food and oven/grill temperatures simultaneously.
- Firxa Wiesgħa ta' Temperatura: 32 sa 572 ° F (0 sa 300 ° C).
- Allarmi Programmabbli: Set desired temperatures for food and oven; an alarm sounds when reached.
- Funzjoni Timer: Includes a 10-hour count up/down timer.
- Kostruzzjoni Durabbli: 6.75-inch (17 cm) stainless steel probe with a 39-inch (1 m) sensor cable.
- Immuntar versatili: Features a magnet for metal surfaces and a fold-out stand for countertops.
- Għażla tal-Unità: Aqleb faċilment bejn Fahrenheit u Celsius.
- Qawwa: Operates on 1 AAA battery (included).
Setup
- Installazzjoni tal-batterija:
Locate the battery compartment on the back of the unit. Insert one AAA battery, ensuring correct polarity. The display will activate.
- Konnessjoni tas-Sonda:
Insert the stainless steel probe's jack firmly into the port on the side of the thermometer unit.

Image: The CDN DSP1 thermometer with its probe securely plugged into the side port.
- Pjazzament:
Position the thermometer unit using either the magnetic back to attach it to a metal surface (e.g., oven door, refrigerator) or extend the fold-out stand for countertop use.

Immaġni: Wara view of the CDN DSP1 thermometer, highlighting the integrated magnet and the fold-out stand for versatile placement.
Istruzzjonijiet Operattivi
Kejl tat-Temperatura
- Daħħal Sonda: Carefully insert the tip of the probe into the thickest part of the food, avoiding bone or gristle. For oven temperature, position the probe tip within the oven cavity, ensuring the cable is not pinched.
- Qawwa Mixgħul: Agħfas il- ON/OFF button to activate the thermometer.
- Agħżel l-Unità: Agħfas il- °F/°C button to toggle between Fahrenheit and Celsius display.
- Set Food Temperature Alarm:
- Agħfas il- MODALITÀ button until "FOOD" is selected.
- Agħfas il- LAĦAM button to cycle through pre-programmed meat types (e.g., Beef, Pork, Chicken) or press SET to manually adjust the target temperature using the HR u MIN buttuni.
- Agħfas ALERT ON/OFF to activate the alarm. The alarm will sound when the food reaches the set temperature.
- Set Oven Temperature Alarm:
- Agħfas il- MODALITÀ button until "OVEN" is selected.
- Agħfas SET to manually adjust the target oven temperature using the HR u MIN buttuni.
- Agħfas ALERT ON/OFF to activate the alarm. The alarm will sound when the oven reaches the set temperature.
Funzjoni Timer
- Agħżel il-Modalità tat-Tajmer: Agħfas il- MODALITÀ button until "TIMER" is selected.
- Issettja Ħin: Uża l- HR u MIN buttons to set the desired countdown time (up to 10 hours).
- Ibda/Waqqaf: Agħfas il- BIDU/WAQQF button to begin or pause the countdown.
- Irrisettja: To clear the timer, press and hold the BIDU/WAQQF buttuna.
Manutenzjoni
- Tindif tas-Sonda: After each use, wipe the stainless steel probe with a damp cloth and mild detergent. Rinse thoroughly and dry completely. Do not immerse the probe cable connector or the main unit in water.
- Tindif tal-Unità: Imsaħ l-unità tat-termometru b'ċarruta ratba uamp drapp. Tużax prodotti tat-tindif li joborxu jew tgħaddasx l-unità fl-ilma.
- Ħażna: Store the thermometer and probe in a clean, dry place when not in use. Ensure the probe cable is not kinked or damaged.
- Sostituzzjoni tal-batterija: Replace the AAA battery when the display becomes dim or unresponsive.

Image: The CDN DSP1 thermometer and its probe laid out on a wooden cutting board, ready for use or cleaning.
Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-ebda wiri jew wiri mudlam | Batterija baxxa jew mejta; installazzjoni ħażina tal-batterija. | Ibdel il-batterija AAA, waqt li tiżgura l-polarità korretta. |
| Qari mhux preċiż tat-temperatura | Probe not fully inserted; probe or cable damage; probe tip touching bone/gristle. | Ensure probe is fully inserted into the thickest part of the food. Avoid bone. Inspect probe and cable for damage. If damaged, replace the probe. |
| L-allarm ma jiddoqqx | Alarm function not activated; volume too low. | Agħfas il- ALERT ON/OFF button to activate. Check for any volume settings (if applicable, though this model typically has a fixed alarm). |
| Probe not registering temperature | Probe not properly connected to the unit. | Ensure the probe jack is firmly seated in the port. |
Speċifikazzjonijiet
- Mudell: DSP1
- Firxa tat-Temperatura: 32 sa 572 ° F (0 sa 300 ° C)
- Tul tas-Sonda: 6.75 pulzieri (17 ċm)
- Tul tal-Cable: 39 pulzier (1 m)
- Sors tal-Enerġija: 1 x batterija AAA (inkluża)
- Tip ta' wiri: LCD diġitali
- Materjali: Acrylonitrile Butadiene Styrene (ABS) casing, Stainless Steel probe and cable
- Karatteristiċi: Dual sensing, programmable alarms, timer, magnet/stand mounting
- Dimensjonijiet (Unità): Approximately 7.5 inches (H) x 3 inches (W) x 0.625 inches (D)

Image: The CDN DSP1 thermometer with key dimensions indicated, showing its compact size.
Informazzjoni dwar Garanzija
CDN products are manufactured with quality materials and craftsmanship. For specific warranty details and terms, please refer to the documentation included with your product or visit the official CDN websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal kwalunkwe talba ta' garanzija.
Appoġġ
For further assistance, product inquiries, or technical support, please contact CDN customer service. Contact information can typically be found on the product packaging or the official CDN websit.
Manifattur: CDN
Websit: www.cdn-timeandtemp.com
Telefon: 800-338-5594