Fluke 725

Manwal tal-Utent tal-Kalibratur tal-Proċess Multifunzjonali Fluke 725

1. Introduzzjoni

This manual provides comprehensive instructions for the safe and effective use of the Fluke 725 Multifunction Process Calibrator. The Fluke 725 is a robust and user-friendly field calibrator designed for testing and calibrating a wide range of process parameters. It combines measurement and source functions to facilitate accurate calibration of transmitters and other industrial equipment.

Key capabilities include sourcing and simulating volts, mA, thermocouples, RTDs, frequency, ohms, and pressure. It also supports flow meter testing with frequency and CPM functions, offers fast linearity tests with auto-step and auto-ramp features, and can power transmitters using its loop supply while simultaneously measuring mA. The device is designed for durability and ease of use in various industrial environments.

2. Setup

2.1 Spakkjar u Spezzjoni

Upon receiving your Fluke 725, carefully unpack the contents. The package should include the Multifunction Process Calibrator unit. Inspect the calibrator for any signs of damage that may have occurred during shipping. If any damage is observed, contact your supplier immediately.

2.2 Installazzjoni tal-batterija

The Fluke 725 operates on four AA alkaline batteries, which are included. The battery compartment is located on the rear of the unit and features an easy-access door for convenient changes.

  1. Locate the battery compartment door on the back of the calibrator.
  2. Open the door by sliding or unlatching it according to the markings.
  3. Insert four AA alkaline batteries, ensuring correct polarity as indicated inside the compartment.
  4. Agħlaq il-bieba tal-kompartiment tal-batterija sew.

2.3 Qawwa Inizjali

Press the power button (typically marked with a circle and a vertical line) to turn on the calibrator. The display should illuminate, indicating the device is ready for operation.

Fluke 725 Multifunction Process Calibrator front view

Figura 1: Quddiem view of the Fluke 725 Multifunction Process Calibrator, showing the display and control buttons.

3. Istruzzjonijiet Operattivi

The Fluke 725 allows simultaneous viewing of input and output on its easy-to-read measure/source screen.

3.1 Kejl Bażiku u Akkwist

The calibrator features dedicated buttons for various measurement and source functions. Use the 'MEAS' button to select measurement mode and the 'SOURCE' button to select source mode. Specific parameters can be selected using the corresponding function buttons (e.g., V mA, TC, RTD, Hz, Ohms).

3.2 Parameter Specific Operations

  • Voltage (V): Measure 0 to 30V, Source 0 to 10V. Resolution up to 0.01V.
  • Kurrent (mA): Measure and Source 0 to 24 mA. Resolution 0.001 mA. Max load for source is 1000 ohm.
  • Thermocouples (TC): Measure and Source mV (TC terminals) from -10.00 mV to 75.00 mV.
  • RTDs: Measure and Source Resistance from 15 to 3200 ohm.
  • Frekwenza (Hz): Measure and Source 2.0 to 1000.0 CPM, 1 to 1000 Hz, 1.0 to 10.0 kHz. For frequency source, the waveform is a 5V p-p squarewave with a -0.1V offset.
  • Ohms (Ω): Measure and Source resistance.
  • Pressjoni: Source pressure (requires external pressure modules, sold separately).

3.3 Karatteristiċi Avvanzati

  • Auto-Step and Auto-Ramp: Perform fast linearity tests using these automated features. Consult the on-screen menu or specific function buttons for activation.
  • Loop Supply: The calibrator provides a 24V DC loop supply to power transmitters during testing, with simultaneous mA measurement capability.
  • Dawl ta' wara: Activate the backlight for improved visibility in low-light conditions.
  • Store Test Setups: Frequently used test configurations can be stored and recalled for efficiency.
Technician using Fluke 725 calibrator to connect to industrial equipment

Figure 2: A technician utilizing the Fluke 725 to connect and calibrate industrial process equipment.

Fluke 725 calibrator connected to a pressure transmitter in an industrial setting

Figure 3: The Fluke 725 calibrator connected to a pressure transmitter, demonstrating its application in process calibration.

Close-up of Fluke 725 calibrator display showing measurements

Figura 4: Close-up view of the Fluke 725 calibrator held in hand, displaying measurement readings.

4. Manutenzjoni

4.1 Sostituzzjoni tal-batterija

When the battery indicator appears on the display, replace the four AA alkaline batteries promptly to ensure continued operation and accuracy. Refer to Section 2.2 for battery installation instructions.

4.2 Tindif

To clean the calibrator, wipe the case with a damp cloth and a mild detergent. Do not use abrasive cleaners, solvents, or harsh chemicals. Ensure the device is powered off and disconnected from any circuits before cleaning.

4.3 Ħażna

Store the Fluke 725 within the specified storage temperature range of -40 °C to 71 °C (-40 °F to 160 °F). For prolonged storage, remove the batteries to prevent leakage.

5 Issolvi l-problemi

If the Fluke 725 does not operate as expected, review the following general troubleshooting steps:

  • Ebda QawwaIċċekkja l-installazzjoni tal-batterija u kun żgur li l-batteriji huma friski.
  • Qari Mhux Korrett: Verify test lead connections, ensure correct function selection, and check for proper calibration.
  • Kwistjonijiet tal-Wiri: If the display is dim, activate the backlight or replace batteries.
  • Function Not Responding: Power cycle the unit (turn off, then on). If the issue persists, consult the manufacturer's support resources.

For specific error codes or advanced troubleshooting, refer to the official Fluke support documentation or contact Fluke customer service.

6. Speċifikazzjonijiet

ParametruFirxaRiżoluzzjoniEżattezza
Voltage (Sors)0 sa 10V0.01V0.02% Rdg + 2 LSD
Voltage (Kejl)0 sa 30V0.01V0.02% Rdg + 2 LSD
Voltage (Kejl)0 sa 100 mV0.01 mV0.02% Rdg + 2 LSD
Kurrent (mA)0 sa 24 mA0.001 mA0.02% Rdg + 2 LSD
mV (TC terminals)-10.00 mV sa 75.00 mV0.01 mV0.025% of range + 1 LSD
Reżistenza15 sa 3200 ohm0.01 sa 0.1 ohm0.10 sa 1.0 ohm
Frequency (CPM)2.0 to 1000.0 CPM0.1 CPM+/-0.05%
Frekwenza (Hz)1 sa 1000 Hz1 Hz+/-0.05%
Frekwenza (kHz)1.0 sa 10.0 kHz0.1 kHz+/-0.25%
Loop Supply24V DCN/A10% preċiżjoni

Speċifikazzjonijiet Ambjentali u Fiżiċi

  • Vol massimutage: 30V
  • Temperatura tal-Ħażna: -40 °C sa 71 °C (-40 °F sa 160 °F)
  • Temperatura operattiva: -10 °C sa 55 °C (14 °F sa 131 °F)
  • Umdità Relattiva: 95% (10 to 35 °C), 75% (30 to 40 °C), 45% (40 to 50 °C), 35% (50 to 55 °C)
  • Xokk: 30g, 11ms, half-sine shock (or 1-meter drop test)
  • Vibrazzjoni: Random, 2g, 5-500 Hz
  • Sigurtà: CSA C22.2 No. 1010.1:1992
  • Batteriji: Four AA alkaline batteries (included)
  • Ħajja tal-batterija: 25 hours typical
  • Dimensjonijiet tal-Prodott: 10 x 7.8 x 3.3 inches; 1 Pound

7. Informazzjoni dwar Garanzija

The Fluke 725 Multifunction Process Calibrator comes with a three-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For detailed warranty terms and conditions, please refer to the official Fluke warranty statement or contact Fluke customer support.

8. Appoġġ u Kuntatt

For technical assistance, service, or additional information regarding your Fluke 725 Multifunction Process Calibrator, please visit the official Fluke Corporation website or contact their customer support department. Contact details can typically be found on the Fluke websit jew fl-ippakkjar tal-prodott.

Manifattur: Fluke Corporation

Dokumenti Relatati - 725

Preview Manwal tal-Utent tal-Kalibratur tal-Proċess Multifunzjonali Fluke 725
User manual for the Fluke 725 Multifunction Process Calibrator, a handheld, battery-operated instrument for measuring and sourcing electrical and physical parameters. Details features, functions, and contact information for Fluke Corporation.
Preview Kalibratur tal-Proċess ta' Dokumentazzjoni Fluke 753: Speċifikazzjonijiet Tekniċi, Karatteristiċi, u Aktarview
Speċifikazzjonijiet tekniċi dettaljati, karatteristiċi ewlenin, u tagħrif dwar il-prodottview għall-Fluke 753 Documenting Process Calibrator, għodda multifunzjonali qawwija għall-kalibrazzjoni u s-soluzzjoni ta' problemi tal-istrumenti tal-proċess.
Preview Gwida għall-Għażla tal-Għodod tal-Proċess Fluke 2025-2026 għal Strumentazzjoni Industrijali u Tekniċi Elettriċi
Esplora l-Gwida tal-Għażla tal-Fluke Process Tools 2025-2026, li tinkludi firxa komprensiva ta' kalibraturi, gauges tal-pressjoni, u aċċessorji għal strumentazzjoni industrijali u tekniċi elettriċi. Skopri kalibraturi tal-linja, kalibraturi tal-pressjoni, kalibraturi tat-temperatura, kalibraturi multifunzjonali, kalibraturi tad-dokumentazzjoni, u aktar.
Preview Manwal tal-Utent tal-Kalibratur tal-Pressjoni Awtomatiku Fluke 729/729 FC
Manwal tal-utent għall-Kalibraturi Awtomatiċi tal-Pressjoni Fluke 729 u 729 FC, li jiddeskrivi l-karatteristiċi, it-tħaddim, il-kompiti ta' kalibrazzjoni, il-manutenzjoni, u l-ispeċifikazzjonijiet għal dawn l-għodod portabbli ta' kalibrazzjoni fuq il-post.
Preview Manwal tal-Kalibrazzjoni tal-Kalibratur tat-Tester Elettriku Multifunzjonali Fluke 5322A
Manwal komprensiv ta' kalibrazzjoni għall-Kalibratur tat-Test Elettriku Multifunzjonali Fluke 5322A, li jiddeskrivi l-proċeduri ta' aġġustament, verifika u manutenzjoni għal ittestjar elettriku preċiż.
Preview Kalibratur Multi-Prodott Fluke 5522A: Manwal tal-Operatur u Speċifikazzjonijiet
Dan il-manwal tal-operatur jipprovdi informazzjoni dettaljata dwar il-Kalibratur Multi-Prodott Fluke 5522A, inklużi l-ispeċifikazzjonijiet, it-tħaddim, is-sigurtà, il-manutenzjoni, u l-għażliet ta' kalibrazzjoni. Tgħallem kif tuża u żżomm il-Fluke 5522A tiegħek għal kompiti ta' kalibrazzjoni preċiżi.