Introduzzjoni

This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your KING KBP2406 KBP Multi-Wattage Compact Unit Heater. Please read all instructions carefully before installation and use to ensure proper function and safety.

Informazzjoni Importanti dwar is-Sigurtà

Setup u Installazzjoni

The KBP2406 unit heater is designed for versatile installation in garages or shops. It comes with a universal wall/ceiling bracket for flexible mounting options.

Immuntar

Utilize the provided universal bracket to securely mount the heater to a wall or ceiling. Ensure the mounting surface can support the weight of the unit (approximately 24 pounds) and that the heater is positioned to allow for efficient air circulation.

KING KBP2406 Compact Unit Heater, angled view

Figura 1: Angolat view of the KING KBP2406 Compact Unit Heater, showing its robust construction and integrated mounting bracket.

Wiring Elettriku

This model operates on 240 Volts, 1 Phase, and requires a dedicated 30 Amp 2-pole breaker. All wiring must be performed by a qualified electrician in accordance with local and national electrical codes. Refer to the wiring diagram located on the unit's back panel for specific connections.

Lura view of KING KBP2406 heater showing electrical label

Figura 2: Wara view of the heater, displaying the product label with electrical specifications and warnings.

Pic-A-Watt Element Selection

The KBP2406 features King's exclusive dual Pic-A-Watt steel fin elements, allowing you to tailor the heater's wattage output to your specific heating requirements. This adjustment is typically made during installation by unplugging one of the elements inside the heater to reduce the total wattage. Consult the detailed wiring instructions provided with the unit for precise wattage konfigurazzjoni.

Vidjo 1: An informational video demonstrating the concept of Pic-A-Watt heaters and how they can be adjusted to meet specific room heating needs during installation.

Chart showing heating coverage for various KBP models

Figura 3: Heating coverage chart illustrating the square footage heated by different KBP models based on wattage, useful for determining appropriate wattage settings.

Istruzzjonijiet Operattivi

Once properly installed and wired, your KBP2406 heater is ready for operation.

Quddiem view of KING KBP2406 heater with control knobs

Figura 4: Front panel of the heater, showing the thermostat control knob and the 3-position selector switch.

Panel tal-Kontroll

The heater features two main controls on its front panel:

Fan Delay Feature

The integral fan delay feature ensures that the fan continues to operate for a short period after the heating elements turn off. This dissipates residual heat from the elements, maximizing heat exchange into the room and extending element life.

Manutenzjoni

Regular maintenance ensures optimal performance and longevity of your heater. Always disconnect power before performing any maintenance.

Issolvi l-problemi

If your heater is not operating correctly, consult the following common issues before contacting customer support.

ProblemaKawża PossibbliSoluzzjoni
Il-heater ma jixgħelx.No power, circuit breaker tripped, selector switch in OFF position.Check power supply, reset circuit breaker, ensure selector switch is in HEAT or FAN position.
Heater runs but no heat.Selector switch in FAN position, thermostat set too low, heating element issue.Set selector switch to HEAT, increase thermostat setting. If problem persists, contact a qualified technician.
Heater cycles on/off too frequently.Thermostat setting too close to ambient temperature, poor air circulation.Adjust thermostat setting. Ensure heater is not obstructed and has adequate clearance for airflow.
Thermostat appears inaccurate.Normal variation, external drafts affecting sensor.Adjust the thermostat to achieve desired comfort level, rather than relying solely on the numerical setting. Ensure heater is not in a drafty area.

Speċifikazzjonijiet

BrandRE
Numru tal-MudellKBP2406
Wattage5700 Watts (adjustable via Pic-A-Watt)
Voltage240 Volts
Ampetà23.8 Amps
Fażi1 Fażi
KulurGriż Onyx
Piż tal-oġġett24 liri
Dimensjonijiet tal-Prodott (L x W x H)13.63 x 10.38 x 11.25 pulzieri
Issettjar tat-Temperatura Min40 Grad Fahrenheit
Issettjar tat-Temperatura Max80 Grad Fahrenheit
Tip ta 'ImmuntarMuntaġġ tal-Ħajt, Muntatura tas-Saqaf
Użu fuq ġewwa/barraĠewwa

Informazzjoni dwar Garanzija

This KING KBP2406 heater comes with a Garanzija Limitata ta' 5 Snin. For detailed terms and conditions, please refer to the warranty card included with your product or visit the manufacturer's websit.

Appoġġ għall-Klijent

For further assistance, technical support, or warranty claims, please contact KING customer service or visit their official websit:

Dokumenti Relatati - KBP2406

Preview King KBP Serje ECO2S+ Heater Kompatt tal-Unità - Effiċjenti fl-Enerġija 2-StagTisħin
Informazzjoni dettaljata dwar il-heater kompatt tas-Serje King KBP ECO2S+, li jinkludi kontroll elettroniku ECO2S+ li jiffranka l-enerġija, 2-stagTisħin elettroniku, sensing tat-temperatura mill-bogħod, u għażliet versatili ta' installazzjoni. Jinkludi speċifikazzjonijiet, informazzjoni dwar l-ordnijiet, u dettalji tal-inġinerija.
Preview Heater tal-Unità b'Bidu Kiesaħ Robust tas-Serje King KBP-RCS - Prestazzjoni Affidabbli sa -40°F
Skopri s-Serje King KBP-RCS, unit heater kompatt u robust iddisinjat għal ambjenti kesħin estremi. Tħaddim affidabbli sa -40°F b'ilma li jista' jintgħażel.tagKostruzzjoni e u heavy-duty għal applikazzjonijiet industrijali u kummerċjali.
Preview King PSH2440TB Heater tal-Ħanut Portabbli: Manwal tal-Installazzjoni, Tħaddim, u Sigurtà
Dan il-manwal komprensiv jipprovdi informazzjoni essenzjali għall-King PSH2440TB Portable Shop Heater, inkluż l-installazzjoni, linji gwida dwar is-sigurtà, struzzjonijiet dwar l-operat, pariri dwar il-manutenzjoni, u soluzzjonijiet għas-soluzzjoni tal-problemi. Iddisinjat għall-użu fil-garaxxijiet u l-ħwienet tax-xogħol, għandu qawwa ta' 3750W u tħaddim ta' 240V.
Preview Gwida għall-Installazzjoni tal-Heater Cove tas-Serje King KCV
Istruzzjonijiet uffiċjali għall-installazzjoni għall-King KCV Series Cove Heater (Mudell KCV1202), li jiddettaljaw il-prekawzjonijiet ta' sigurtà, is-setup elettriku, l-immuntar, il-wajers, u l-manutenzjoni.
Preview Heater Spazjali Elettriku tas-Serje King W: Gwida għall-Installazzjoni, it-Tħaddim, u l-Manutenzjoni
Gwida komprensiva għall-ħiters elettriċi tal-ispazju tas-Serje King W, li tkopri l-installazzjoni, il-wajers, it-tħaddim, it-twissijiet ta' sigurtà, is-soluzzjoni tal-problemi, il-manutenzjoni, u informazzjoni dwar il-garanzija.
Preview King KDSR Series Electric Heater Installation, Operation, and Maintenance Manual
Comprehensive guide for King KDSR Series electric heaters (2 kW to 5 kW), covering installation, safe operation, and regular maintenance. Includes important safety warnings and instructions for standard and suspended ceiling mounting.