Mastech M300

Mastech M300 Mini Digital Multimeter User Manual

Mudell: M300

1. Introduzzjoni

The Mastech M300 is a compact, 13-range mini digital multimeter designed for basic electrical measurements. It is capable of measuring AC/DC voltage up to 500 volts, DC current up to 200 mA, resistance, diode continuity, and features a buzzer for continuity checks. Its attached test leads make it highly portable and convenient for various applications.

2. Informazzjoni dwar is-Sigurtà

WARNING: To avoid electrical shock, remove input leads before opening the case. To prevent fire, install the fuse with the specified amp/volt ratings.

  • Dejjem kun żgur li l-multimetru huwa ssettjat għall-medda korretta qabel ma tieħu l-kejl.
  • Tippruvax tkejjel il-voltages jew kurrenti li jaqbżu l-limiti massimi speċifikati.
  • Oqgħod attent ħafna meta taħdem ma' ċirkwiti ħajjin.
  • Spezzjona l-wajers tat-test għal ħsara qabel kull użu. Tużax jekk l-insulazzjoni tkun kompromessa.
  • Never open the multimeter casing unless absolutely necessary for maintenance (e.g., fuse replacement) and ensure it is disconnected from all power sources.
  • This device is rated for CAT III 600V.
Lura view of the Mastech M300 multimeter showing safety warnings and battery compartment

Figura 2.1: Wara view of the Mastech M300 multimeter, displaying important safety warnings regarding electrical shock and fuse specifications. The battery compartment is also visible.

3. Karatteristiċi tal-prodott

  • Miżuri AC/DC Voltage sa 500V.
  • Measures DC Current up to 200mA.
  • Measures Resistance (0-2MΩ).
  • Diode and Continuity Test with Buzzer.
  • Konsum ta 'enerġija baxxa għal ħajja estiża tal-batterija.
  • Overload indication for safety.
  • Integrated test leads for convenience.
Quddiem view of the Mastech M300 Mini Digital Multimeter with attached test leads

Figura 3.1: Quddiem view of the Mastech M300 Mini Digital Multimeter, showing the LCD display, rotary switch, function buttons, and integrated red and black test leads.

4. Kontenut tal-Pakkett

Malli tiftaħ il-pakkett, jekk jogħġbok ivverifika li l-oġġetti kollha huma preżenti u mhux imħassra:

  • Mastech M300 Mini Digital Multimeter (with attached test leads)
  • SR44 3V Batteries (x2, pre-installed)
  • Manwal għall-Utent

5. Setup

5.1 Installazzjoni/Sostituzzjoni tal-Batterija

The Mastech M300 uses two SR44 3V batteries, which are typically pre-installed. If replacement is needed:

  1. Ensure the multimeter is turned OFF and disconnect all test leads from any circuits.
  2. Sib il-kompartiment tal-batterija fuq wara tal-unità (ara l-Figura 2.1).
  3. Iftaħ b'attenzjoni l-għatu tal-kompartiment tal-batterija.
  4. Remove the old batteries and insert new SR44 3V batteries, observing the correct polarity (+/-).
  5. Agħlaq sewwa l-għatu tal-kompartiment tal-batterija.

5.2 Konnessjoni tal-wajers tat-test

The Mastech M300 features integrated test leads. Ensure they are securely attached to the meter and free from any damage before use.

6. Istruzzjonijiet Operattivi

Before making any measurement, ensure the multimeter is set to the appropriate function and range. The rotary switch is used to select the desired measurement type.

6.1 Kejl DC Voltage (V–)

  1. Issettja s-swiċċ rotatorju għall-Volum DC mixtieqtage range (e.g., 500V, 200V, 20V, 2V, 200mV). Start with the highest range if the voltage mhux magħruf.
  2. Qabbad il-wajer tat-test aħmar man-naħa pożittiva (+) taċ-ċirkwit u l-wajer tat-test iswed man-naħa negattiva (-).
  3. Aqra l-voltage valur fuq il-wiri LCD.

6.2 Kejl AC Voltage (V∼)

  1. Issettja s-swiċċ rotatorju għall-Volum AC mixtieqtage range (e.g., 500V, 200V). Start with the highest range if the voltage mhux magħruf.
  2. Qabbad il-wajers tat-test mal-vultaġġ ACtagsors e.
  3. Aqra l-voltage valur fuq il-wiri LCD.

6.3 Measuring DC Current (A–)

CAUTION: To measure current, the multimeter must be connected in series with the circuit. Never connect the multimeter in parallel across a voltage source when in current mode, as this can damage the meter and the circuit.

  1. Set the rotary switch to the desired DC Current range (e.g., 200mA, 20mA, 2mA, 200µA).
  2. Break the circuit where you want to measure current.
  3. Connect the red test lead to the higher potential side of the break and the black test lead to the lower potential side, completing the circuit through the multimeter.
  4. Aqra l-valur kurrenti fuq il-wiri LCD.

6.4 Kejl tar-Reżistenza (Ω)

CAUTION: Ensure the circuit or component is completely de-energized before measuring resistance. Measuring resistance on a live circuit can damage the multimeter.

  1. Set the rotary switch to the desired Resistance range (e.g., 2MΩ, 200kΩ, 20kΩ, 2kΩ, 200Ω).
  2. Connect the test leads across the component whose resistance you wish to measure.
  3. Aqra l-valur tar-reżistenza fuq id-displej LCD.

6.5 Test tad-Diode

  1. Set the rotary switch to the Diode symbol (→|–).
  2. Connect the red test lead to the anode of the diode and the black test lead to the cathode. The display will show the forward voltagqatra e.
  3. Reverse the leads. The display should show 'OL' (Open Loop) for a good diode.

6.6 Test ta' Kontinwità

  1. Set the rotary switch to the Continuity symbol (♫).
  2. Connect the test leads across the component or wire you wish to test.
  3. If there is continuity (low resistance), the buzzer will sound, and the display will show a low resistance value. If there is no continuity, the display will show 'OL'.

7. Manutenzjoni

7.1 Tindif

Biex tnaddaf il-multimetru, imsaħ il-kaxxa b'adamp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the unit is completely dry before use.

7.2 Sostituzzjoni tal-Fjus

If the current measurement function stops working, the fuse may need replacement. Refer to the safety warnings on the back of the unit for fuse specifications (F 250mA/250V).

  1. Kun żgur li l-multimetru jkun MITFI u skonnettja l-wajers tat-test kollha.
  2. Open the multimeter casing (this typically involves removing screws on the back).
  3. Locate the fuse and carefully remove it.
  4. Replace with a fuse of the exact same type and rating (F 250mA/250V).
  5. Agħlaq is-c sewasing.

8 Issolvi l-problemi

  • No Display / Faint Display: Check battery charge. Replace batteries if necessary.
  • Qari Skorrett: Ensure the rotary switch is set to the correct function and range. Verify test lead connections. Ensure the circuit is de-energized for resistance measurements.
  • No Current Measurement: Check the fuse. Replace if blown (refer to Section 7.2).
  • Wiri 'OL' (Tagħbija żejda): The measured value exceeds the selected range. Switch to a higher range or verify the circuit.

9. Speċifikazzjonijiet

Numru tal-MudellM300
DC Voltage FirxaSa 500V
AC Voltage FirxaSa 500V
Medda tal-Kurrent DCSa 200mA
Firxa tar-reżistenza0-2MΩ
Test tad-DiodeIva
Test ta' KontinwitàYes (with Buzzer)
Sors tal-Enerġija2 x SR44 3V Batteries
Dimensjonijiet12.07 x 1.91 x 6.99 ċm
Piż90 g
Klassifikazzjoni tas-SigurtàCAT III 600V

10. Garanzija u Appoġġ

This Mastech M300 Mini Digital Multimeter comes with a garanzija ta 'sena mid-data tax-xiri, li tkopri difetti fil-manifattura. Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal talbiet ta' garanzija.

For technical support, warranty service, or inquiries, please contact Mastech customer service through their official websit jew il-bejjiegħ bl-imnut minn fejn inxtara l-prodott.

Dokumenti Relatati - M300

Preview MASTECH M300 Digital Multimeter User Manual
User manual for the MASTECH M300 digital multimeter, detailing its features, specifications, safety precautions, and operating instructions for measuring DC/AC voltage, DC current, resistance, continuity, and diode testing.
Preview MASTECH MS2016A Tnixxija Clamp Manwal tat-Tħaddim tal-Miter
Manwal komprensiv tat-tħaddim għall-MASTECH MS2016A AC Leakage Clamp Miter, li jkopri informazzjoni dwar is-sigurtà, speċifikazzjonijiet, gwida dwar l-operat, manutenzjoni, u aċċessorji. Il-karatteristiċi jinkludu vol AC/DCtagKejl tar-reżistenza, tal-kapaċitanza, tal-kontinwità, tad-dijodi, u tat-temperatura.
Preview Gwida għall-Bidu Mgħaġġel tal-MASTECH MS8223A Multimetru Diġitali tat-Tip Pinna
Gwida ta' bidu rapidu għall-multimetru diġitali tat-tip pinna MASTECH MS8223A, li tkopri l-prekawzjonijiet ta' sigurtà, l-ispeċifikazzjonijiet, u t-tħaddim bażiku għall-volumtage, kurrent, reżistenza, kontinwità, test tal-loġika, u skoperta tal-NCV.
Preview Gwida għall-Bidu Mgħaġġel tal-Multimetru Diġitali MASTECH MS8250D
Gwida konċiża u ottimizzata għall-SEO għall-MASTECH MS8250D Digital Multimeter, li tipprovdi informazzjoni essenzjali dwar is-sigurtà, l-ispeċifikazzjonijiet, u t-tħaddim bażiku.
Preview Manwal tal-Utent tal-Multimetru Diġitali Mastech: Karatteristiċi, Speċifikazzjonijiet, u Gwida għat-Tħaddim
Manwal komprensiv għall-utent għall-multimetru diġitali li jinżamm fl-idejn Mastech. Ikopri l-karatteristiċi, il-prekawzjonijiet ta' sigurtà, l-ispeċifikazzjonijiet ġenerali u tekniċi, u l-istruzzjonijiet operattivi għall-volum.tagKejl tal-e, kurrent, reżistenza, dijodu, kontinwità, batterija, u transistor, skoperta tal-NCV, u manutenzjoni.
Preview MASTECH MS2108 AC/DC Clamp Gwida għall-Bidu Mgħaġġel tal-Miter
A concise quick start guide for the MASTECH MS2108 AC/DC Clamp Meter, detailing safety precautions, technical specifications, and basic usage instructions for measuring voltage, kurrent, reżistenza, kapaċità, u frekwenza.