Directed 528T

Directed Electronics Inc 528T 12V Accessory Pulse Timer User Manual

Introduzzjoni

The Directed Electronics Inc 528T is a versatile 12-volt accessory pulse timer designed for automotive and other low-voltage applications. It features an adjustable delay from 0 to 60 seconds and can be triggered by either a positive or negative pulse, or a state change. This manual provides essential information for proper installation, operation, and maintenance of your 528T unit.

Informazzjoni dwar is-Sigurtà

Prodott Overview

The 528T unit consists of a compact electronic module with multiple color-coded wires for various connections and an adjustable potentiometer for setting the delay time.

Directed 528T Pulse Timer with wires

Image: Directed 528T Pulse Timer showing the clear casing, internal circuit board, and various colored wires extending from the unit.

Directed 528T Pulse Timer top view

Immaġni: Minn fuq għal isfel view of the Directed 528T Pulse Timer, highlighting the compact design and the bundle of wires.

Komponenti

Speċifikazzjonijiet

KaratteristikaDettall
Input Voltage12V DC
Timer aġġustabbli0 - 60 Seconds
Output Relay30A (massimu)
Tip ta' TriggerPositive (+) or Negative (-) Pulse, or State Change
Dimensjonijiet tal-Prodott3.05 x 8 x 5 pulzieri
Piż tal-oġġett3.2 uqija
Numru tal-Mudell528T

Setup u Installazzjoni

Proper installation of the 528T unit requires a basic understanding of automotive electrical systems. Refer to your vehicle's wiring diagrams as needed.

Dijagramma tal-Wajers u Konnessjonijiet

The 528T unit features several color-coded wires. Identify each wire's function before making connections.

Trigger Type Selection

The 528T can be configured for either positive or negative triggering using the blue wire loop.

Proċedura ta' Konnessjoni

  1. Konnessjonijiet tal-Enerġija: Qabbad il- Aħmar wire to a fused 12V constant power source and the Iswed wire to a solid chassis ground.
  2. Trigger Konnessjoni: Based on your desired trigger type, connect either the Iswed/Abjad wire (for negative trigger, blue loop intact) or the Isfar wire (for positive trigger, blue loop cut) to your trigger source. The unused trigger wire should be insulated.
  3. Konnessjoni tat-Tagħbija: Connect the device you wish to control to the appropriate relay output wire.
    • Uża l- Oranġjo wire for a Normally Open (NO) connection. This means the circuit is open (off) until the timer activates, then it closes (on) for the set duration.
    • Uża l- Kannella wire for a Normally Closed (NC) connection. This means the circuit is closed (on) until the timer activates, then it opens (off) for the set duration.
  4. Insulazzjoni: Ensure all connections are properly soldered or crimped and insulated with electrical tape or heat shrink tubing.
  5. Immuntar: Mount the 528T unit in a dry, secure location away from excessive heat or vibration.

Istruzzjonijiet Operattivi

Adjusting the Timer Delay

The 528T features an adjustable potentiometer (a small dial or screw) on the unit's circuit board. This allows you to set the delay time from approximately 0 to 60 seconds.

Attivazzjoni ta' Timer

Once installed and configured, the timer activates upon receiving the specified trigger signal (positive or negative, depending on the blue loop setting).

Manutenzjoni

Issolvi l-problemi

Unit Does Not Activate

Incorrect Delay Time

Relay Not Switching

Garanzija u Appoġġ

Specific warranty information for the Directed Electronics Inc 528T is not provided in this manual. Please refer to the product packaging or contact Directed Electronics Inc directly for warranty details and technical support.

For further assistance, it is recommended to consult with an authorized Directed Electronics dealer or a qualified automotive electronics technician.

Dokumenti Relatati - 528T

Preview Directed GM5 Installation Guide: Vehicle Wiring and Programming
Comprehensive installation guide for the Directed GM5 remote start system, covering vehicle wiring, module programming, troubleshooting, and safety precautions. Includes detailed wiring diagrams and vehicle application charts.
Preview Gwida għall-Installazzjoni Diretta tal-GM10
Gwida komprensiva għall-installazzjoni għas-sistema ta' startjar mill-bogħod u sigurtà Directed GM10, li tiddeskrivi fid-dettall il-wajers, il-kompatibilità tal-vettura, u l-ipprogrammar għal vetturi Buick, Chevrolet, u GMC.
Preview Gwida ta' Installazzjoni ta' Referenza Rapida għal SmartStart Pro DSM550/VSM550 Diretta
Gwida ta' referenza rapida għall-installazzjoni u l-attivazzjoni tal-moduli Directed SmartStart Pro DSM550 u VSM550. Tkopri l-proċeduri ta' installazzjoni, il-wajers, il-konfigurazzjoni, l-attivazzjoni, u s-soluzzjoni tal-problemi, flimkien ma' twissijiet importanti dwar is-sigurtà u informazzjoni dwar il-garanzija.
Preview Gwida għall-Installazzjoni ta' Chrysler għal Soluzzjonijiet Diġitali Diretti
Din il-gwida għall-installazzjoni tipprovdi struzzjonijiet dettaljati għall-installazzjoni tal-firmware ta' Directed Digital Solutions għal vetturi Chrysler, Dodge/RAM, Jeep, Mitsubishi, u Volkswagen. Tkopri l-konnessjonijiet tal-wajers, gwidi tal-applikazzjoni tal-vetturi, u s-soluzzjoni tal-problemi.
Preview Gwida għall-Installazzjoni ta' DS4+ GM10 Diretta
Gwida komprensiva għall-installazzjoni għas-sistema ta' startjar u sigurtà mill-bogħod Directed DS4+ bil-firmware GM10, li tkopri l-wajers, il-kompatibilità tal-vettura, il-konfigurazzjoni, u s-soluzzjoni tal-problemi għal installaturi professjonali.
Preview Directed 5105V/5105P/5105X/5105A/5105L Owner's Guide - Vehicle Security & Remote Start System
Comprehensive owner's guide for Directed 5105 series vehicle security and remote start systems, covering installation, operation, features, troubleshooting, and warranty. Learn how to use your car alarm and remote start system effectively.