1. Introduzzjoni
This manual provides detailed instructions for the setup, operation, and maintenance of your Oregon Scientific THGR228NF Wireless Remote Sensor. This sensor is designed to monitor both temperature and humidity, transmitting data wirelessly to compatible Oregon Scientific weather stations, such as the Ferrari Monza, Ferrari Modeno, or Ferrari Maranello Projection Clock.
The device is splash-proof, making it suitable for various remote outdoor or indoor environments like yards, greenhouses, or auto shops. Please read this manual thoroughly before using the sensor to ensure proper functionality and longevity.
2. Kontenut tal-Pakkett
Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett tiegħek:
- Oregon Scientific THGR228NF Wireless Remote Sensor
- 2 x Batteriji AAA
3. Prodott Aktarview
The THGR228NF sensor features a clear digital LCD display for local readings and a robust casing designed for remote placement.

This image displays the Oregon Scientific THGR228NF Wireless Remote Sensor. The front features a digital LCD screen showing temperature (30.8°C) and humidity (30%), along with 'DRY' and 'CH 2' indicators. Below the screen, a small red LED indicator is visible. The text '433MHz CABLE FREE' is printed, followed by the 'Oregon Scientific' logo at the bottom. The device has a dark grey casing with a checkered pattern around the LCD display.
Komponenti Ewlenin:
- Display LCD: Shows current temperature and humidity.
- Kompartiment tal-batterija: Located on the back, for AAA batteries.
- Swiċċ tal-Kanal: Allows selection of transmission channel (1, 2, or 3) to avoid interference with other sensors.
- Buttuna Irrisettja: Recesses button for restarting the sensor.
4. Setup
4.1 Installazzjoni tal-batterija
- Open the battery compartment cover on the back of the sensor.
- Daħħal iż-żewġ batteriji AAA, waqt li tiżgura l-polarità korretta (+ u -).
- Agħlaq l-għatu tal-kompartiment tal-batterija sew.
4.2 Għażla tal-Kanal
Before placing the sensor, select a transmission channel (1, 2, or 3) using the switch inside the battery compartment. If you are using multiple remote sensors, ensure each sensor is set to a different channel to prevent interference.
4.3 It-tqabbil mal-Unità Prinċipali
After installing batteries and selecting a channel, the sensor will automatically begin transmitting data. To receive data on your main Oregon Scientific weather station (e.g., Ferrari Monza, Modeno, or Maranello), refer to your main unit's instruction manual for specific pairing procedures. Typically, this involves initiating a sensor search function on the main unit.
4.4 Linji Gwida dwar il-Pjazzament
- Place the sensor within the recommended transmission range of your main weather station (typically up to 30 meters / 100 feet, line of sight).
- Avoid placing the sensor near large metal objects, electrical appliances, or other sources of interference.
- While splash-proof, avoid direct exposure to heavy rain or submersion in water. Position it in a sheltered location if possible.
- For accurate temperature readings, avoid direct sunlight.
5. Operazzjoni
5.1 Qari tad-Displej
The sensor's LCD display shows the current temperature in Celsius or Fahrenheit (depending on the main unit's setting or internal switch, if available) and relative humidity. It also indicates the selected channel (e.g., 'CH 2').
5.2 Trażmissjoni tad-Data
The sensor transmits data periodically to the main weather station. The red LED indicator on the front of the sensor may flash briefly during transmission.
6. Manutenzjoni
6.1 Sostituzzjoni tal-batterija
When the battery low indicator appears on the sensor's display or the main unit, replace the batteries promptly. Use only new AAA batteries. Follow the battery installation steps in Section 4.1.
6.2 Tindif
Naddaf is-sensor b'artab, damp drapp. Tużax prodotti tat-tindif jew solventi li joborxu, għax dawn jistgħu jagħmlu ħsara lis-casing jew wiri.
6.3 Konsiderazzjonijiet Ambjentali
Although splash-proof, prolonged exposure to extreme weather conditions (e.g., heavy rain, direct intense sunlight, freezing temperatures) can affect performance and lifespan. Store the sensor indoors if not in use for extended periods.
7 Issolvi l-problemi
- No display on sensor: Check battery polarity. Replace batteries if low. Press the reset button.
- No data received by main unit:
- Ensure the sensor and main unit are within range.
- Verify the sensor's channel matches the channel selected on the main unit for that sensor.
- Check for sources of interference (e.g., other electronic devices).
- Re-initiate the sensor search on the main unit.
- Ibdel il-batteriji tas-sensor.
- Qari mhux korrett: Ensure the sensor is not in direct sunlight or near heat/cold sources. Allow time for readings to stabilize after placement.
8. Speċifikazzjonijiet
| Numru tal-Mudell | THGR228NF |
| Brand | Oregon Xjentifiku |
| Teknoloġija tas-Sensers | Sensor bla fili |
| Tip ta 'Wiri | LCD |
| Monituri | Temperatura u Umdità |
| Sors tal-Enerġija | Mħaddma bil-batterija |
| Batteriji Meħtieġa | 2 x AAA (inklużi) |
| Karatteristika Speċjali | Prova tat-titjir |
| Kulur | Iswed tal-Karbonju |
| Dimensjonijiet | Madwar 4 x 1.75 x 6.9 pulzieri |
| Piż tal-oġġett | 204 g |
| UPC | 734811207081 |
9. Garanzija u Appoġġ
9.1 Informazzjoni dwar Garanzija
This product typically comes with a 1-year limited warranty from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty covers manufacturing defects but does not cover damage caused by misuse, accidents, or unauthorized modifications.
9.2 Appoġġ għall-Klijent
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Oregon Scientific customer support. Refer to the official Oregon Scientific webis-sit għall-aktar informazzjoni ta' kuntatt u riżorsi ta' appoġġ aġġornati.