1. Introduzzjoni u Fuqview
The SK120X is a third-generation upgraded NC Lift Voltage DC Adjustable Regulated Power Supply designed for precise voltage and current control. It features a large, all-viewing-angle VA color LCD screen for clear display of parameters and easy operation. This module is suitable for various engineering projects requiring stable and adjustable power output, including solar charging applications.
Il-karatteristiċi ewlenin jinkludu:
- CNC voltage and current adjustment for high precision.
- Professional power liquid crystal display with a clear interface.
- Comprehensive hardware and software protection mechanisms.
- Ability to set default adjustment voltage or constant current values for quick application.
- Voltage and current locking to prevent accidental changes.

2. Product Components and Setup
The SK120X module incorporates robust components and various interfaces for versatile use. Before operation, familiarize yourself with the physical layout and connection points.

2.1. Konnessjonijiet Fiżiċi
- Qawwa tad-Dħul: Connect your DC power source to the IN+ and IN- terminals. Ensure the input voltage is within the specified range of DC 5.0V-30V. For optimal performance, an input voltage above 7V is recommended.
- Tagħbija tal-Output: Connect your load or battery to the OUT+ and OUT- terminals. The module features anti-backflow protection, allowing direct connection to a battery for charging without an additional diode.
- Sensor tat-Temperatura Esterni: If desired, connect a 10k NTC 3905B external temperature probe to the dedicated interface. The device will automatically display the probe's temperature.
2.2. Interfejsijiet ta' Komunikazzjoni
The SK120X supports various communication options:
- Komunikazzjoni Serjali: A serial communication interface is available.
- XY-K485X Module: Can be connected to an XY-K485X module for 485 bus control.
- Modulu WiFi: Connect a WiFi module for remote control via an APP and web-based networking.
- Infrared Receiver Module: Connect an infrared receiver module for efficient and fast remote control.
3. Istruzzjonijiet Operattivi
The SK120X features an intuitive UI for monitoring and setting parameters.
3.1. Product UI Function Details

When the power supply is ON, the main UI displays output voltage (CV), output current (A), and output power (W). The encoder button can be pressed to toggle through additional displays such as capacity (Ah), energy (Wh), time (h), and temperature (°C).
When the power is OFF, the set voltage (CV) and set current (CC) are displayed alternately. If an external temperature probe is connected, its temperature will also be displayed.
3.2. UI Parameter Settings

Biex tidħol fil-menu tas-settings:
- Agħfas u żomm il- SET button on the main interface.
- The first parameter displayed allows you to select the data group (e.g., Cxd-x).
- Agħfas fil-qosor VSET biex tagħżel il-parametru li jmiss.
- Agħfas fil-qosor ISET biex tagħżel il-parametru preċedenti.
- To adjust a parameter value, rotate the encoder.
- After completing your settings, press and hold the ISET/SW/encoder button to exit the settings interface.
Il-parametri disponibbli jinkludu:
- Cxd-x: Select data group.
- SET CV: Issettja l-output voltage.
- SET CC: Set output current.
- LVP: L-input undervoltage protection (default 5.5V).
- OVP: Ħruġ żejjedtage protection (default 38V).
- OCP: Output overcurrent protection (default 6.2A).
- OPP: Output overpower protection (default 125W).
- OAH: Overcapacity protection (default OFF).
- OPH: Overenergy protection (default OFF).
- OHP: Overtime protection (default OFF).
- OTP: Overtemperature protection (default 95°C).
- ETP: External overtemperature protection (default OFF).
- PON: Automatically enabled during power-on (default OFF).
4. Manutenzjoni
No specific maintenance procedures are provided for this product. It is recommended to keep the device clean and free from dust. Ensure proper ventilation to prevent overheating, especially during high-power operation.
5 Issolvi l-problemi
The SK120X is equipped with several built-in protection features to ensure safe operation and prevent damage. If the device unexpectedly shuts down or does not operate as expected, consider the following:
- Input Undervoltage Protection (LVP): Jekk l-input voltage drops below 4.7V (or the set LVP value), the device may reduce output power or shut down. Ensure your input power source is stable and provides sufficient voltage (recommended >7V).
- Output Overvoltage Protezzjoni (OVP): Jekk l-output voltage exceeds the set OVP limit (default 38V), the device will activate protection. Check your load and settings.
- Protezzjoni ta' Kurrent Żejjed tal-Ħruġ (OCP): If the output current exceeds the set OCP limit (default 6.2A), the device will activate protection. Verify your load's current draw and adjust settings if necessary.
- Output Overpower Protection (OPP): If the output power exceeds the set OPP limit (default 125W), the device will activate protection. Reduce the load or ensure adequate cooling.
- Protezzjoni minn Temperatura Żejda (OTP): If the internal temperature reaches 100°C (or the set OTP limit), the device will shut down to prevent damage. Ensure the fan is unobstructed and the device has sufficient ventilation.
- Input Reverse Connection Protection: The device is protected against reverse connection at the input terminals. If connected incorrectly, it will not burn, but it will not operate. Correct the polarity.
- Protezzjoni ta' Short Circuit tal-Ħruġ: The output terminals are protected against short circuits. If a short circuit occurs, the device will not be damaged. Remove the short circuit.
- Output Anti-backflow: When charging a battery, the anti-backflow protection prevents current from flowing back into the power supply. If charging is not occurring, check battery connections.
6. Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Input Voltage | DC 5.0V - 30V (LVP below 4.7V, recommended >7V) |
| Ħruġ Voltage | DC 0.6V - 30V |
| Kurrent tal-Ħruġ | 0 - 4.0A |
| Qawwa tal-Ħruġ | 35W (natural heat dissipation), 50W (air cooling). Max 150W (software supported, optimal cooling). |
| Voltage Preċiżjoni | 0.5% + 1 word, Resolution: 0.01V |
| Eżattezza Kurrenti | 0.8% + 3 words, Resolution: 0.001A |
| Effiċjenza tal-Konverżjoni | Madwar 88% |
| Soft Start | Iva |
| Protezzjoni tal-Konnessjoni b'lura tad-dħul | Iva |
| Output Anti-backflow | Iva |
| Protezzjoni Short Circuit Output | Iva |
| Protezzjoni minn temperatura żejda (OTP) | Iva, f'100°C |
| Frekwenza Operattiva | 180KHz |
| Materjal | Plastik |
| Kulur | Abjad |
| Dimensjonijiet (L x W x H) | 11 ċm x 7 ċm x 5 ċm |
| Piż | 0.15 kg |
6.1. Prodott Views





7. Għajnuniet għall-Utenti
Ma kien hemm l-ebda pariri speċifiċi għall-utent disponibbli minn reviews or Q&A for this product. However, based on the product's features, here are some general tips:
- Always ensure your input voltage is stable and within the specified range to prevent triggering undervoltagprotezzjoni.
- When operating at higher power outputs (above 35W), ensure adequate airflow around the device or use active air cooling to prevent overtemperature protection from activating.
- Uża l-volumtage and current locking feature to prevent accidental changes to your settings during critical operations.
- Familiarize yourself with the various protection settings (OVP, OCP, OPP, OTP, LVP) and adjust them according to your application's requirements for optimal safety and performance.
8. Garanzija u Appoġġ
No specific warranty information or dedicated support contact details are provided in the product description. For any issues or inquiries, please refer to the seller or your point of purchase.