BLE-3188 BLE-3188

Manwal tal-Utent tat-Tester tal-Kwalità tal-Ilma WiFi BLE-3188 7-f'1

Online Water Monitor for PH/ORP/EC/PPM/CF/Humidity/Temperature Testing

Introduzzjoni

The BLE-3188 is a sophisticated 7-in-1 WiFi water quality tester designed for real-time monitoring of various water parameters. This device features a detachable multifunctional electrode design, allowing for precise measurement of PH, ORP (Oxidation-Reduction Potential), EC (Electrical Conductivity), PPM (Parts Per Million), CF (Conductivity Factor), humidity, and temperature.

It integrates seamlessly with the Tuya Smart APP via WiFi, providing stable data transmission. Users can download the app to view current and historical data directly on their mobile phones. The app also includes an abnormal high and low data alarm function, ensuring users are promptly notified of any critical changes in water quality. The long-term data recording capability facilitates easy comparison and analysis, aiding in the development of effective solutions for water management.

This multi-parameter intelligent water quality detector offers strong practicality and is ideal for a wide range of applications, including aquariums, hydroponics systems, aquaculture, swimming pools, drinking water analysis, and laboratory use.

Kontenut tal-Pakkett

Please check the package contents carefully upon unboxing. If any items are missing or damaged, please contact customer support.

  • 1 x BLE-3188 Water Quality Tester Main Unit
  • 1 x PH Probe
  • 1 x ORP Probe
  • 1 x EC/PPM/CF/SALT/S.G Probe
  • 1 x Sonda tat-Temperatura
  • 1 x Adapter tal-Enerġija
  • 1 x Manwal għall-Utent
Package contents of the BLE-3188 water quality monitor, including the main unit, probes, power adapter, and manual.
Figure 1: BLE-3188 Water Quality Tester Package Contents

Prodott Overview

The BLE-3188 features a clear display and intuitive controls for easy operation. Familiarize yourself with the components and their functions:

Labeled diagram of the BLE-3188 tester showing components like Power Adapter, PH/TEMP Display, ORP Display, PPM/EC/SALT/S.G/CF Display, ORP Calibration key, PPM/EC/SALT/S.G/CF Switch Key, EC/ORP+ Calibration key, C/F Switch Key, TEMP Connection Probe, ORP Connection Probe, PH Connection Probe, PPM/EC/SALT/S.G/CF Connection Probe.
Figure 2: BLE-3188 Component Diagram
  • Adapter tal-Enerġija: Connects to the main unit for power.
  • PH/TEMP Display: Shows pH and temperature readings.
  • ORP Display: Shows ORP readings.
  • PPM/EC/SALT/S.G/CF Display: Shows readings for various conductivity-related parameters.
  • ORP Calibration Key (CAL): Used for ORP calibration.
  • PPM/EC/SALT/S.G/CF Switch Key (MODE): Short press to cycle through PPM/EC/SALT/S.G/CF measurements.
  • EC/ORP+ Calibration Key (CAL): Used for EC/PPM/CF/SALT/S.G calibration.
  • °C/°F Switch Key (T/C): Jaqleb bejn l-unitajiet tat-temperatura Celsius u Fahrenheit.
  • TEMP Connection Probe: Port for the temperature probe.
  • ORP Connection Probe: Port for the ORP probe.
  • PH Connection Probe: Port for the PH probe.
  • PPM/EC/SALT/S.G/CF Connection Probe: Port for the multi-parameter conductivity probe.
  • Buttuna ON/OFF: Jixgħel jew jitfi l-apparat.
  • WiFi On/Off (MODE Long Press): Long press the MODE button to toggle WiFi connectivity.
Dimensions of the BLE-3188 tester: 152mm/5.98in (length), 78mm/3.07in (width), 25mm/0.98in (height), and wire length 1.1m/43.31in.
Figure 3: BLE-3188 Dimensions

Setup

  1. Ippakkja: Neħħi bir-reqqa l-komponenti kollha mill-imballaġġ.
  2. Qabbad is-Sondi:
    • Connect the PH probe to the "PH Connection Probe" port.
    • Connect the ORP probe to the "ORP Connection Probe" port.
    • Connect the EC/PPM/CF/SALT/S.G probe to the "PPM/EC/SALT/S.G/CF Connection Probe" port.
    • Connect the Temperature probe to the "TEMP Connection Probe" port.
  3. Qawwa Mixgħul: Connect the power adapter to the main unit and then plug it into a suitable power outlet. The device should power on automatically or can be turned on using the ON/OFF button.
  4. Pjazzament Inizjali: Place the probes into the water solution you wish to monitor. Ensure the probes are fully submerged but the main unit remains dry.

Nota Importanti: This tester is not waterproof. Please do not allow the instrument to come into contact with water or become damp during use, as this may cause malfunction.

Istruzzjonijiet Operattivi

Operazzjoni Bażika

  • Power On/Off: Use the dedicated ON/OFF button to turn the device on or off.
  • Għażla tal-Unità tat-Temperatura: Press the "T/C" button to switch the temperature display between Celsius (°C) and Fahrenheit (°F).
  • Measurement Mode Selection (EC/PPM/CF/SALT/S.G): Short press the "MODE" button located under the PPM/EC/SALT/S.G/CF display to cycle through the different measurement parameters (PPM, EC, SALT, S.G, CF).
  • Wifi mixgħul/mitfi: Long press the "MODE" button to toggle the WiFi function on or off.
Hand pressing the 'MODE' key to select measurement (short press) or turn WiFi on/off (long press), showing various display modes for PPM, EC, SALT, S.G, and CF.
Figure 4: Mode Selection and WiFi Control

Kalibrazzjoni

Regular calibration ensures the accuracy of your water quality tester. Calibration solutions are typically required and sold separately.

  1. PH Calibration:
    • Prepare standard pH buffer solutions (e.g., pH 4.00, pH 6.86, pH 9.18).
    • Laħlaħ l-elettrodu tal-pH b'ilma distillat u nixxef b'ilma xott.
    • Submerge the pH electrode into the first buffer solution.
    • Press the "CAL" button under the PH/TEMP display. Follow the on-screen instructions or refer to the specific calibration procedure in the full manual (if available) for multi-point calibration.
    • Repeat for other buffer solutions as needed.
  2. ORP Calibration:
    • Prepare a standard ORP calibration solution.
    • Rinse the ORP electrode with distilled water and blot dry.
    • Submerge the ORP electrode into the calibration solution.
    • Press the "CAL" button under the ORP display. Adjust as per the calibration solution's value.
  3. EC/PPM/CF/SALT/S.G Calibration:
    • Prepare a standard EC calibration solution (e.g., 1413 µS/cm).
    • Rinse the EC probe with distilled water and blot dry.
    • Submerge the EC probe into the calibration solution.
    • Press the "CAL" button under the PPM/EC/SALT/S.G/CF display. Adjust according to the calibration solution's value.

Always ensure probes are clean before calibration and use fresh calibration solutions for best results.

Mobile App Integration (Tuya Smart APP)

The BLE-3188 water quality tester can be connected to the Tuya Smart APP for enhanced monitoring and data management. The app is compatible with both Apple (iOS) and Android systems.

  1. Niżżel l-App: Fittex għal "Tuya Smart" in your device's app store (Google Play Store for Android, Apple App Store for iOS) and install it.
  2. Reġistrazzjoni/Idħol: Open the Tuya Smart APP and register for a new account or log in with an existing one.
  3. Qabbad mal-WiFi:
    • Ensure the BLE-3188 tester is powered on.
    • Long press the "MODE" button on the tester until the WiFi indicator starts blinking, indicating it's in pairing mode.
    • In the Tuya Smart APP, follow the instructions to add a new device. Select the appropriate device type (e.g., "Water Quality Monitor" or "Sensor").
    • Follow the in-app prompts to connect the device to your home WiFi network.
  4. Monitoraġġ f'ħin reali: Ladarba tkun imqabbda, tista ' view real-time data for PH, ORP, EC, PPM, CF, humidity, and temperature directly on your smartphone.
  5. Dejta Storika: L-app tippermettilek view historical data recorded over various periods (day, week, month) for trend analysis.
  6. Funzjoni ta' allarm: Set custom high and low alarm thresholds for each parameter. The app will notify you if readings fall outside these ranges.
  7. Esportazzjoni tad-Dejta: The app supports exporting data to Excel format. You can send the data directly to your email for further analysis and sharing.
    Steps for data export from the Tuya Smart APP: Click Export, Enter Email, then download, view, and share the Excel file.
    Figure 5: Data Export via Tuya Smart APP

    Data export frequency: The system can export 60 groups of hourly data, 7 groups of weekly data, and 30 groups of monthly data. For daily data, it exports 24 groups from the previous day plus several groups from the current day (depending on the time of day). To prevent malicious attacks, each mailbox can receive a maximum of 55 sets of data within 24 hours (30 sets of Days, Weeks or Month, and 25 sets of Hour).

Mobile application monitoring (PH-W218) showing various screens of the Tuya Smart APP for temperature, PH, TDS, and EC, compatible with Apple and Android.
Figure 6: Tuya Smart APP Interface Examples

Manutenzjoni

  • Tindif tas-Sonda: Regularly clean the electrodes with distilled water to remove any residue that may affect accuracy. For stubborn deposits, use a soft brush or a mild cleaning solution specifically designed for pH/ORP/EC probes.
  • Probe Storage:
    • PH Probe: Store the pH electrode in a pH storage solution (e.g., 3M KCL solution) or a pH 4.0 buffer solution when not in use. Do not store in distilled water as this can dehydrate the bulb and shorten its lifespan.
    • ORP/EC Probes: These probes can generally be stored dry or in distilled water, but refer to specific probe instructions if available.
  • Kura Ġenerali: Keep the main unit dry and clean. Avoid exposing it to direct sunlight, extreme temperatures, or corrosive environments.
  • Sostituzzjoni tal-batterija: (If applicable, though this model appears to be AC powered) If the device uses batteries, replace them when the low battery indicator appears to ensure continuous operation and accurate readings.

Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Qari mhux eżattProbes are dirty or damaged; Calibration is outdated or incorrect; Incorrect measurement mode selected.Clean probes thoroughly. Recalibrate the device using fresh standard solutions. Ensure the correct measurement mode (PPM, EC, etc.) is selected.
Apparat Mhux JixgħelL-adapter tal-enerġija mhux imqabbad sew; Problema bis-sokit tal-enerġija.Check power adapter connection. Try a different power outlet. Ensure the ON/OFF button is pressed.
WiFi Connection FailureIncorrect WiFi password; Device too far from router; WiFi function not enabled on tester; App pairing issue.Verify WiFi password. Move the tester closer to the WiFi router. Long press the MODE button to ensure WiFi is enabled. Restart the app and try pairing again. Ensure your router is on a 2.4GHz network.
No Data on AppDevice not connected to WiFi; App not refreshed; Probes not submerged.Check WiFi connection status. Refresh the app. Ensure all probes are correctly submerged in the water.

Speċifikazzjonijiet

Detailed specifications table for Range, Resolution, Accuracy, Operating Temperature, Temperature Compensation, Power Supply, Dimensions, and Weight of the BLE-3188 water quality tester.
Figure 7: BLE-3188 Detailed Specifications
ParametruFirxaRiżoluzzjoniEżattezza
PH0.00 - 14.00PH0.01PH±0.03 PH
ORP-2000mV - +2000mV1mV±5mV
EC0 - 19000µS/cm, 0 - 199.0mS/cm1µS/cm (<1999), 10µS/cm (>1999), 0.1mS/cm± 2% FS
CF0 - 1999.0CF0.1CF± 2% FS
TDS0 - 19990ppm, 0 - 199.0ppt1ppm (<1999), 10ppm (>1999), 0.1ppt± 2% FS
SG0.990 - 1.4000.001± 2% FS
MELĦ0 - 199.9ppt, 0% - 20%0.1ppt, 0.01%± 2% FS
Temperatura0 - 50°C (32 - 122°F)0.1°C (0.2°F)±1.0°C (±2°F)
  • Temperatura operattiva: 0°C ~ 50°C
  • Kumpens tat-Temperatura: 0°C ~ 50°C
  • Provvista tal-Enerġija: DC6V
  • Dimensjonijiet: 152 mm x 80 mm x 26 mm
  • Piż: 245g

Għajnuniet għall-Utent

  • For consistent and accurate readings, always ensure your probes are clean and properly calibrated before each use or monitoring session.
  • When monitoring continuously, periodically check the probe condition and recalibrate as needed, especially for pH and ORP probes which can drift over time.
  • Utilize the Tuya Smart APP's alarm functions to set critical thresholds for your water parameters. This can provide early warnings for potential issues in your aquarium, hydroponic system, or other applications.
  • Ħu bil-quddiemtage of the app's data logging and export features to track trends and make informed decisions about your water quality management.

Garanzija u Appoġġ

Għal informazzjoni dwar il-garanzija, appoġġ tekniku, jew mistoqsijiet dwar is-servizz, jekk jogħġbok irreferi għall-informazzjoni ta' kuntatt ipprovduta mill-bejjiegħ bl-imnut tiegħek jew mir-rappreżentant uffiċjali tal-manifattur. websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal kwalunkwe talba ta' garanzija.

Dokumenti Relatati - BLE-3188

Preview Manwal tal-Utent tat-Tester tal-Pixxina Bluetooth 6-f'1 BLE-YC01
Manwal komprensiv għall-utent għat-Tester tal-Pixxini Bluetooth 6-f'1 BLE-YC01, li jkopri l-kejl tal-pH, EC, TDS, CL, ORP, u Temperatura. Jinkludi speċifikazzjonijiet dettaljati, proċeduri ta' kalibrazzjoni, ġestjoni tad-dejta, u struzzjonijiet operattivi għal ittestjar ottimali tal-kwalità tal-ilma.
Preview Manwal ta' Istruzzjoni għall-Monitor tal-Pixxina Floating Bluetooth 6-f'1
Manwal ta' struzzjonijiet komprensiv għall-Bluetooth 6-in-1 Floating Pool Monitor, li jagħti dettalji dwar il-parametri, l-operat, il-kalibrazzjoni u l-informazzjoni dwar il-garanzija tiegħu għal ittestjar preċiż tal-ilma tal-pixxina.
Preview YINMIK BLE-C600 Bluetooth 7-f'1 Tester tal-Kwalità tal-Ilma: Istruzzjonijiet u Speċifikazzjonijiet
Gwida komprensiva għat-Tester tal-Kwalità tal-Ilma YINMIK BLE-C600 Bluetooth 7-f'1, li tkopri s-setup, it-tħaddim, il-kalibrazzjoni, il-karatteristiċi, u informazzjoni dwar il-garanzija.
Preview Manwal ta' Istruzzjoni għall-Monitor tal-Pixxina Floating Bluetooth 6 f'1
Manwal ta' struzzjonijiet komprensiv għall-Bluetooth 6 f'1 Floating Pool Monitor (pH/EC/SALT/CL/ORP/TEMP Meter), li jkopri l-parametri, it-tħaddim, il-kalibrazzjoni, il-ġestjoni tad-dejta, u informazzjoni dwar il-garanzija.
Preview BLE-C600 Multi-Parameter Water Quality Tester Manual
Instruction manual for the BLE-C600 multi-parameter water quality tester, covering its features, operation, and calibration for pH, EC, TDS, Salt, SG, and ORP.
Preview YINMIK BLE-9908 Bluetooth Water Quality Tester pH Calibration Guide
Instructions for calibrating the YINMIK BLE-9908 Bluetooth 4-in-1 Water Quality Tester, detailing its parameters, range, and operation for accurate water quality testing.