Fujitsu S26113-E567-V50-02 DPS-500XB A

Fujitsu S26113-E567-V50-02 DPS-500XB A Server Power Supply User Manual

Model: S26113-E567-V50-02 DPS-500XB A

Introduzzjoni

This manual provides essential information for the proper installation, operation, and maintenance of the Fujitsu S26113-E567-V50-02 DPS-500XB A Server Power Supply. This unit is designed to provide stable and reliable power to compatible server systems. Please read this manual thoroughly before installation and use.

Fujitsu DPS-500XB A Server Power Supply front view
Quddiem view of the Fujitsu DPS-500XB A Server Power Supply, showing the main power connector.

Speċifikazzjonijiet

The following table details the technical specifications of the Fujitsu S26113-E567-V50-02 DPS-500XB A Power Supply:

Product label with detailed electrical specifications for Fujitsu DPS-500XB A power supply
Detailed product label showing model, input, and output specifications.
Karatteristika Dettall
Numru tal-Mudell S26113-E567-V50-02, DPS-500XB A
Manifattur Fujitsu Technology Solutions
Max Output Power 500W
Input AC 100-240V~, 7-3.5A, 50-60Hz
DC Output +12V1 17A (18A 20SEC)
DC Output +12V2 17A (18A 20SEC)
DC Output +12V3 15A (18A 20SEC)
DC Output +12V4 15A (18A 20SEC)
DC Output +12V5 17A (18A 20SEC)
DC Output +12V6 0.5A (1A 20SEC)
AUX DC Output +12V 1A
AUX DC Output +5V 2A
DC Output +11V 2A (2.5A 1SEC)
Fannijiet 1
Tip PFC Attiva
Konnettur tal-Enerġija tas-CPU 4 pin
Applikazzjoni Desktop
Modulari Mhux Modulari
Ċertifikazzjoni 80 PLUS Deheb
Oriġini Iċ-Ċina kontinentali
Kundizzjoni Second hand, Tested working 100%

Setup u Installazzjoni

Proper installation is crucial for the safe and efficient operation of your power supply. Always ensure the server system is powered off and disconnected from the main power source before beginning installation.

  1. Is-Sigurtà l-Ewwel: Disconnect all power cables from the server and ensure no residual power remains. Wear an anti-static wrist strap to prevent electrostatic discharge (ESD) damage to components.
  2. Neħħi l-PSU l-Qadim (jekk applikabbli): Carefully disconnect all cables from the existing power supply unit (PSU). Unscrew and remove the old PSU from the server chassis.
  3. Installa PSU Ġdid: Gently slide the Fujitsu DPS-500XB A power supply into the designated PSU bay in your server chassis. Ensure it is seated correctly and align the screw holes.
  4. PSU Sikura: Use the appropriate screws to firmly secure the power supply to the server chassis.
  5. Qabbad Kejbils tal-Enerġija:
    • Connect the main ATX power connector to the motherboard.
    • Connect the 4-pin CPU power connector to the motherboard.
    • Connect any necessary peripheral power cables (SATA, Molex, PCIe, etc.) to your drives, expansion cards, and other components. Ensure all connections are firm and correctly oriented.
  6. Ġestjoni tal-Kejbil: Route cables neatly to improve airflow and prevent interference with other components.
  7. Kontroll Finali: Double-check all connections to ensure they are secure and correctly installed.
  8. Qawwa Mixgħul: Connect the server's power cord to the PSU and then to a grounded electrical outlet. Power on the server.
Ġenb view of the power supply showing the AC input port and ventilation grill
Ġenb view of the power supply, highlighting the AC input and cooling fan area.

Istruzzjonijiet Operattivi

Once installed, the power supply operates automatically to deliver power to your server components. No specific user interaction is typically required during normal operation.

  • Power On/Off: The power supply is controlled by the server's power button and operating system. Ensure the server is properly shut down before disconnecting power.
  • Ventilazzjoni: Ensure the server chassis has adequate ventilation to allow proper airflow for the power supply's cooling fan. Blocked vents can lead to overheating and component failure.
  • Sors ta 'Enerġija Stabbli: Connect the server to a stable and grounded power outlet. Using a surge protector or Uninterruptible Power Supply (UPS) is recommended to protect against power fluctuations.
Wara view of the power supply showing the fan and cable exit point
Wara view of the power supply, showing the cooling fan.

Manutenzjoni

Regular, simple maintenance can extend the lifespan of your power supply and ensure optimal performance.

  • Tneħħija tat-Trab: Periodically clean dust from the power supply's fan and ventilation grilles using compressed air. Ensure the server is powered off and unplugged before cleaning.
  • Spezzjona Kejbils: Occasionally check power cables for any signs of wear, fraying, or damage. Replace damaged cables immediately.
  • Kundizzjonijiet Ambjentali: Operate the server in a clean, dry, and well-ventilated environment within recommended temperature ranges to prevent overheating.

Issolvi l-problemi

Jekk tiltaqa' ma' problemi bil-provvista tal-enerġija tiegħek, irreferi għall-passi komuni li ġejjin għas-soluzzjoni tal-problemi:

  • Ebda Qawwa:
    • Kun żgur li l-korda tal-enerġija hija pplaggjata sew kemm fil-PSU kif ukoll fis-sokit tal-ħajt.
    • Ivverifika li s-sokit tal-ħajt jaħdem billi tqabbad apparat ieħor.
    • Check all internal power connections (motherboard, CPU, peripherals) are firmly seated.
  • Instabbiltà tas-Sistema/Għeluq każwali:
    • This could indicate an overloaded or failing PSU. Ensure your system's power requirements do not exceed the PSU's 500W capacity.
    • Check for overheating. Ensure proper ventilation and clean any dust from the PSU fan.
  • Storbju Qawwi tal-Fann:
    • Excessive fan noise can be caused by dust accumulation. Clean the fan blades and grille.
    • If the noise persists, the fan bearing might be failing, which could require professional service or replacement.
  • Riħa ta' Ħruq:
    • Immediately power off and unplug the server. Do not attempt to use it. This indicates a serious electrical fault and requires professional inspection.

Għajnuniet għall-Utent

  • Given this is a second-hand unit, it's advisable to perform a thorough visual inspection for any physical damage or signs of wear before installation.
  • Always ensure compatibility with your server's motherboard and chassis form factor before attempting installation.
  • When replacing a power supply, take note of the original cable routing to simplify the installation of the new unit.

Garanzija u Appoġġ

This product comes with a 3-month warranty period, effective from the date the package is delivered. The warranty covers manufacturing defects and operational failures under normal use.

  • Esklużjonijiet tal-garanzija: The warranty is void if the product is damaged due to improper use, unauthorized modifications, or physical abuse.
  • Appoġġ Tekniku: For technical assistance or warranty claims, please contact your vendor or the original manufacturer, Fujitsu Technology Solutions.
  • Politika ta' Ritorn u Rifużjoni: For details regarding returns and refunds, please refer to the specific policy provided by your seller at the time of purchase.