LILYTECH ZL-7918A

ZL-7918A Multifunctional Automatic Incubator Temperature Humidity Controller

Model: ZL-7918A

1. Introduzzjoni

The ZL-7918A is an intelligent, stable, and user-friendly temperature and humidity controller designed for various applications including incubators, climate chambers, and warehouses. This manual provides detailed instructions for the proper installation, operation, and maintenance of your ZL-7918A controller to ensure optimal performance and longevity.

2. Prodott Aktarview

The ZL-7918A features a clear digital display for both temperature (PV TEMP) and humidity (PV WET), along with set values (SV). It includes control buttons for 'Set', 'Up', 'Down', and 'Enter', as well as indicators for various functions like fan, heating, egg turning, humidity, and alarm states.

Vidjo: Viżjoni ta' 360 grad view of the ZL-7918A controller, showcasing its front panel, sides, and rear wiring terminals.

Quddiem view of the ZL-7918A controller with digital displays and control buttons.

Image: Front panel of the ZL-7918A controller, showing the digital temperature and humidity displays, status indicators, and control buttons.

3. Speċifikazzjonijiet

MaterjalABS
KulurIswed
Provvista tal-EnerġijaAC 100 ~ 240V 50/60Hz
Sensuri1 Temperature Sensor (L=2.0m), 1 Humidity Sensor (L=2.0m)
Firxa ta 'Setting ta' Umdità10 ~ 80% RH
Firxa tal-issettjar tat-temperatura1 ~ 65℃
Medda ta 'Wiri ta' Umdità0 ~ 99% RH
Firxa tal-Wiri tat-Temperatura-9.9 ~ 99 ℃
Humidity Measuring Accuracy±3%@25℃
Preċiżjoni tal-Kejl tat-Temperatura±1%@25℃
Kontroll tal-Produzzjoni7 outputs (Main-Heater, Aux-Heater, Fan, Egg Left-Turning, Egg Right-Turning, Humidity, Illumination)
Heater Output Load≤ 1500W
Illumination Output Load≤ 100W
Other Output Loads (Humidity, Fan, Egg Turnings)≤ 1A/250V AC
Hatching Day RecordMax 99 ijiem
Egg-Turning Control Period1 ~ 999 minuta
Egg-Turning Time0 ~ 999 sekonda
Egg-Turning Times0 ~ 999 darbiet
Ventilation Control Period1 ~ 999 minuta
Ventilating Time0 ~ 999 sekonda
Illumination Control Period1 ~ 999 minuta
Ħin li Jdawwal0 ~ 999 sekonda
Operazzjoni Ambjent-10~45℃, <90%RH without dew
Daqs tal-Oġġett160 * 95 * 80mm / 6.3 * 3.7 * 3.1in
Installation Drilling Size151.5 * 76.5mm / 6.0 * 3.0 pulzieri

4. Kontenut tal-Pakkett

Upon opening your ZL-7918A package, please verify that all the following items are included:

  • 1 x ZL-7918A Incubator Controller
  • 2 x Connection Cables (for sensors)
  • 1 x Manwal tal-Utent (dan id-dokument)

5. Setup u Wiring

Careful wiring is essential for the safe and correct operation of the ZL-7918A controller. Refer to the wiring diagram and terminal table below for detailed connection instructions. Ensure all power is disconnected before performing any wiring.

Detailed wiring diagram for the ZL-7918A incubator controller, showing connections for power, sensors, fan, egg turning, humidifier, lamp, and heaters.

Image: ZL-7918A Wiring Diagram

Terminal connection table for ZL-7918A, detailing each pin's function and corresponding wire colors for sensors.

Image: ZL-7918A Terminal Connection Table

5.1. Sensor Connections

  • Senser tal-Umdità: Connect the Red, Yellow, Black, and Orange wires of the humidity sensor to terminals 1, 2, 3, and 4 respectively.
  • Sensor tat-temperatura: Connect the temperature sensor to terminals 5 and 6.

5.2. Provvista ta 'Enerġija

  • Connect the Neutral (N) wire of your 100-240Vac power supply to terminal 13.
  • Connect the Live (L) wire of your 100-240Vac power supply to terminal 14.

5.3. Konnessjonijiet Output

All output devices (Fan, Egg Turning, Humidifier, Lamp) share a common connection (COM) at terminal 15. Heaters have dedicated terminals.

  • Fann: Connect one wire of the fan to terminal 15 (COM) and the other to terminal 16 (FAN). (Max 1A/250V AC)
  • Egg Turning (Left): Connect one wire of the left egg-turning motor to terminal 15 (COM) and the other to terminal 17 (LEFT). (Max 1A/250V AC)
  • Egg Turning (Right): Connect one wire of the right egg-turning motor to terminal 15 (COM) and the other to terminal 18 (RIGHT). (Max 1A/250V AC)
  • Umidifikatur: Connect one wire of the humidifier to terminal 15 (COM) and the other to terminal 19 (WET). (Max 1A/250V AC)
  • Lamp (Illumination): Connect one wire of the lamp to terminal 15 (COM) and the other to terminal 20 (LAMP). (Max 1A/250V AC, total illumination load ≤ 100W)
  • Auxiliary Heater (HEAT2): Connect the auxiliary heater to terminals 21 and 22. (Max 10A/220Vac, total heater load ≤ 1500W)
  • Main Heater (HEAT1): Connect the main heater to terminals 23 and 24. (Max 10A/220Vac, total heater load ≤ 1500W)

Warning: Ensure all connections are secure and correctly matched to avoid damage to the controller or connected devices. Consult a qualified electrician if you are unsure about any wiring steps.

6. Istruzzjonijiet Operattivi

The ZL-7918A controller is designed for intuitive operation. The front panel features a digital display and four control buttons: SET, UP, DOWN, and ENTER.

6.1. Power On/Off

  • To power on, ensure all wiring is complete and secure, then connect the controller to the AC 100~240V power supply.
  • To power off, disconnect the controller from the power supply.

6.2. Setting Temperature and Humidity

  1. Agħfas il- SET button once to enter the temperature setting mode. The temperature SV (Set Value) will flash.
  2. Uża l- UP u 'L isfel buttuni biex taġġusta t-temperatura mixtieqa.
  3. Agħfas DĦUL to confirm the temperature setting and move to humidity setting mode. The humidity SV will flash.
  4. Uża l- UP u 'L isfel buttons to adjust the desired humidity.
  5. Agħfas DĦUL again to confirm the humidity setting and exit the setting mode.

6.3. Advanced Settings (Egg Turning, Ventilation, Illumination)

To access advanced settings for egg turning, ventilation, and illumination, typically a long press of the SET button or a combination of buttons is required. Refer to the full user manual (if provided separately) for specific parameter codes and adjustment procedures. The general parameters are:

  • Egg-Turning Control: Period (1~999 minutes), Turning Time (0~999 seconds), Turning Times (0~999 times).
  • Kontroll tal-ventilazzjoni: Period (1~999 minutes), Ventilating Time (0~999 seconds).
  • Kontroll tal-Illuminazzjoni: Period (1~999 minutes), Illuminating Time (0~999 seconds).

6.4. Hatching Day Record

The controller can record hatching days up to a maximum of 99 days. The method to reset or view this record will be detailed in the comprehensive manual.

7. Manutenzjoni

Regular maintenance ensures the longevity and accuracy of your ZL-7918A controller.

  • Tindif: Wipe the controller's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
  • Kura tas-Sensor: Keep the temperature and humidity sensors clean and free from dust or debris. Avoid submerging them in water or exposing them to extreme physical shock.
  • Kundizzjonijiet Ambjentali: Operate the controller within the specified environment: -10~45℃ and <90%RH without dew. Extreme conditions can affect performance and lifespan.
  • Kontroll tal-Konnessjoni: Periodically inspect all wiring connections to ensure they remain tight and free from corrosion.

8 Issolvi l-problemi

If you encounter issues with your ZL-7918A controller, try the following troubleshooting steps:

  • Ebda Qawwa: Check the power supply connection and ensure the outlet is functional. Verify the power wiring to terminals 13 and 14.
  • Qari Skorrett: Ensure sensors are correctly connected to their respective terminals (1-4 for humidity, 5-6 for temperature). Check for any physical damage or obstruction to the sensors.
  • Outputs Mhux Attivati: Verify the wiring for the specific output (heater, fan, etc.) to terminals 15-24. Check the set parameters for temperature, humidity, and timing functions to ensure they are within the desired range and trigger conditions.
  • Allarm Attivat: Check the current temperature and humidity readings against the set alarm thresholds. Address the environmental condition causing the alarm.
  • Kwistjonijiet tal-Wiri: If the display is erratic or blank, power cycle the device. If the problem persists, contact support.

9. Għajnuniet għall-Utenti

  • Tqegħid tas-Sensor: Position the temperature and humidity sensors in a location that accurately reflects the conditions within your incubator or climate chamber, away from direct heat sources or airflow.
  • Kalibrazzjoni: While the controller is factory calibrated, if you suspect inaccuracies, consider using a trusted external thermometer/hygrometer to verify readings. Some advanced controllers may offer calibration options (refer to the full manual).
  • Stabbiltà tal-Enerġija: Use a stable power source. Fluctuations can affect the controller's performance and lifespan.
  • Monitoraġġ Regolari: Even with automatic control, periodic manual checks of temperature and humidity are recommended, especially during critical periods like hatching.

10. Garanzija u Appoġġ

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.


LILYTECH ZL-7918A Automatic Incubator Temperature Humidity Controller Overview

LILYTECH ZL-7918A Automatic Incubator Temperature Humidity Controller Overview

0:37 • 720×720 • viżwali_fuqview
LILYTECH ZL-7918A Temperature and Humidity Controller Visual Overview

LILYTECH ZL-7918A Temperature and Humidity Controller Visual Overview

0:37 • 720×720 • viżwali_fuqview

Dokumenti Relatati - ZL-7918A

Preview Kontrollur tal-Umdità u t-Temperatura LILYTECH ZL-7958A għal Inkubaturi - Manwal tal-Utent
Manwal dettaljat għall-utent għall-Kontrollur tal-Umdità u t-Temperatura LILYTECH ZL-7958A, iddisinjat għal inkubaturi u kmamar tal-klima. Tgħallem dwar il-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim u l-wajers tiegħu.
Preview Manwal tal-Kontrollur tal-Umdità u t-Temperatura LILYTECH ZL-7801D
Gwida komprensiva għall-kontrollur universali tat-temperatura u l-umdità LILYTECH ZL-7801D, li tiddeskrivi l-karatteristiċi, l-ispeċifikazzjonijiet, it-tħaddim, is-settings tal-parametri, il-loġika tal-kontroll, u l-wajers tiegħu. Adattat għal inkubaturi, kmamar tal-klima, serer, u mħażen.
Preview LILYTECH ZL-7903A Temperature and Humidity Controller - User Manual & Specifications
Comprehensive user manual and technical specifications for the LILYTECH ZL-7903A industrial intelligent temperature and humidity controller. Covers features, functions, parameters, wiring, and PID control.
Preview Kontrollur tat-Temperatura ZL-6231A: Manwal ta' Istruzzjonijiet | Lilytech
Manwal ta' struzzjonijiet komprensiv għall-Kontrollur tat-Temperatura Lilytech ZL-6231A, li jiddeskrivi l-ispeċifikazzjonijiet, it-tħaddim, is-settings tal-parametri, l-installazzjoni, u l-wajers elettriċi tiegħu għal diversi applikazzjonijiet.
Preview Manwal ta' Istruzzjoni tal-Kontrollur tat-Temperatura ZL-6231A | LILYTECH
Manwal ta' struzzjoni uffiċjali għall-Kontrollur tat-Temperatura LILYTECH ZL-6231A. Karatteristiċi, speċifikazzjonijiet, tħaddim, settings tal-parametri, installazzjoni, u dijagrammi tal-wajers.
Preview ZL-R300A Heat Pump Water Heating/Cooling Controller Manual A5.0
User manual for the LILYTECH ZL-R300A Heat Pump Water Heating/Cooling Controller, detailing hardware, functions, specifications, operation, control, protection, and failure codes for efficient climate management.