mypin DA8-RRB

mypin DA8-RRB Digital Sensor Meter Instruction Manual

Multi-Functional Intelligent LED Display with 2 Relay Alarm Output

1. Introduzzjoni

The mypin DA8-RRB is a versatile digital sensor meter designed for precise measurement and monitoring of various industrial signals. It features a clear 4-digit LED display for Process Value (PV) and Set Value (SV), and supports multiple input types including 0-75mV, 4-20mA, and 0-10V. Equipped with two relay alarm outputs, this meter provides stable performance and is easy to operate, making it suitable for integration with a wide range of sensors such as transformers, pressure sensors, weighing sensors, and more.

2. Informazzjoni dwar is-Sigurtà

  • Always disconnect power before making any wiring connections or performing maintenance.
  • Ensure all wiring is done by qualified personnel and complies with local electrical codes.
  • Ivverifika l-provvista tal-enerġija voltage matches the meter's specifications (90-265V AC/DC).
  • Avoid exposing the device to excessive moisture, dust, or extreme temperatures.
  • Do not attempt to open or repair the device yourself; refer to qualified service personnel.
  • Żgura ertjar xieraq biex tevita xokk elettriku.

3. Prodott Aktarview

3.1 Panel ta 'Quddiem

Front panel of mypin DA8-RRB Digital Sensor Meter
Figure 1: Front panel showing PV/SV displays, control buttons, and alarm indicators (AL1, AL2, OUT).

The front panel features a large 4-digit LED display for the Process Value (PV) and a smaller 4-digit LED display for the Set Value (SV). Control buttons include SET, <<RST (Reset/Shift), Up arrow, and Down arrow for configuration and operation. Indicators for AL1, AL2 (Alarm 1, Alarm 2), and OUT (Output) are also present.

3.2 Rear Panel and Terminals

Rear panel with terminal block and wiring diagram
Figura 2: Wara view of the meter, detailing the terminal block for power, input, and output connections, along with product specifications.

The rear panel houses the terminal block for all electrical connections, including power input, auxiliary power, sensor inputs, and relay outputs. A detailed wiring diagram is provided on the label for easy installation.

3.3 Clips tal-Immuntar

Ġenb view of the meter with mounting clips
Figura 3: Ġenb view showing the included mounting clips for panel installation.

The meter comes with mounting clips for secure panel installation. These clips slide into grooves on the side of the meter and are tightened to hold the unit in place.

4. Speċifikazzjonijiet

ParametruSpeċifikazzjoni
MudellDA8-RRB
Sinjal ta 'Input0-75mV, 4-20mA, 0-10V
Provvista tal-Enerġija90-265V AC / DC
Provvista ta 'Enerġija Awżiljarja24V DC
Konsum tal-EnerġijaInqas minn 3W
Eżattezza0.3%F.S ±2dgt
SampRata tal-linarda≤8 times/second
Ħruġ ta' Allarm2 x RELAY (Normal Open, AC250V/3A or DC 30V/3A COS=1)
Output Analog4-20mA (Wiring not explicitly shown on provided diagram)
Dimensjonijiet (W x H x D)48mm x 96mm x 80mm
Piż171g
MaterjalABS

5. Setup

5.1 Installazzjoni

  1. Prepare a panel cutout of appropriate dimensions for the meter (typically 45mm x 92mm, though not explicitly stated, this is standard for 48x96mm meters).
  2. Insert the meter into the panel cutout from the front.
  3. Slide the provided mounting clips into the grooves on the sides of the meter from the rear.
  4. Tighten the screws on the mounting clips to secure the meter firmly in the panel.

5.2 Dijagramma tal-Wiring

Detailed wiring diagram on the meter's rear label
Figure 4: Close-up of the wiring diagram on the rear label. Refer to this diagram for all electrical connections.

5.3 Konnessjonijiet Terminali

Refer to Figure 4 and the following instructions for correct wiring:

Terminal Nru.DeskrizzjoniNoti
1, 2Power Supply (90-265V AC/DC)Connect to main power source.
3, 4Auxiliary Power (24V DC)For external devices or sensors requiring 24V DC.
5, 6Alarm Output 1 (AL1)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
7, 8Alarm Output 2 (AL2)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
9Common (com.mV.mA.V)Common terminal for mV, mA, and V inputs.
10mV / mA InputConnect positive terminal of 0-75mV or 4-20mA sensor here.
11Voltage Input (V)Connect positive terminal of 0-10V sensor here.
12Pożittiv (+)Typically for 4-wire sensors or external sensor power.

Importanti: Ensure correct polarity for all input signals. Incorrect wiring can damage the meter or sensor.

6. Istruzzjonijiet Operattivi

6.1 Mixgħul

After completing all wiring, apply power to the meter. The LED displays will illuminate, showing the current Process Value (PV) and potentially a Set Value (SV).

6.2 Funzjonijiet tal-buttuni

  • Buttuna SET: Użat biex tidħol fil-modalità tal-issettjar tal-parametri u tikkonferma l-għażliet.
  • <<RST button: Used to shift digits during value setting or to reset certain functions.
  • Up (↑) button: Used to increase values or navigate through menu options.
  • Down (↓) button: Used to decrease values or navigate through menu options.

6.3 Basic Operation (General)

While specific programming steps are not detailed in the provided information, typical operation involves:

  1. ViewPV/SV tal-ing: The main display shows the current Process Value (PV). The smaller display shows the Set Value (SV), which might be an alarm setpoint or other configured parameter.
  2. Parametri tal-issettjar: Press the SET button to enter the parameter setting mode. Use the Up/Down arrows to select parameters and adjust their values. Use the <<RST button to shift between digits when setting numerical values. Press SET again to confirm and save changes.
  3. Funzjoni ta' allarm: The AL1 and AL2 indicators will light up when the measured PV exceeds or falls below their respective setpoints, triggering the corresponding relay outputs.

For detailed parameter configuration, refer to the full product manual (if available from the manufacturer) or contact technical support.

7. Manutenzjoni

  • Tindif: Imsaħ bil-mod id-displej u ċasinNaddaf b'ċarruta ratba u niexfa. Tużax prodotti tat-tindif jew solventi li joborxu.
  • Kontroll tal-Konnessjoni: Spezzjona perjodikament il-konnessjonijiet tal-wajers kollha biex tiżgura li huma sikuri u ħielsa mill-korrużjoni.
  • Kundizzjonijiet Ambjentali: Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the life of the device.

8 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-miter ma jixgħelx.L-ebda provvista tal-enerġija jew wajers mhux korretti.Check power connections (Terminals 1, 2) and ensure voltage is within 90-265V AC/DC.
Display shows "----" or erratic readings.Incorrect sensor wiring, sensor malfunction, or wrong input type selected.Verify sensor connections (Terminals 9-12) and ensure the sensor is functioning correctly. Check meter configuration for correct input signal type.
Alarm outputs (AL1/AL2) not activating.Alarm setpoints incorrect or relay wiring issue.Check alarm setpoints (SV) and ensure they are configured correctly relative to the PV. Verify wiring to external alarm devices (Terminals 5-8).
Qari mhux preċiż.Sensor calibration issue or environmental interference.Calibrate the sensor if possible. Ensure the meter is not exposed to strong electromagnetic interference.

9. Għajnuniet għall-Utenti

  • Input Signal Selection: Before connecting your sensor, ensure the meter is configured for the correct input signal type (mV, mA, or V) to avoid incorrect readings or potential damage.
  • Tikkettjar ċar: For complex setups, clearly label all wires connected to the terminal block to simplify future troubleshooting or maintenance.
  • Allarmi tat-Test: After setting alarm points, perform a test to ensure the relay outputs activate as expected.

10. Garanzija u Appoġġ

For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Dokumenti Relatati - DA8-RRB

Preview MYPIN D Series Intelligent Sensor Meter Instruction Manual | Specifications & Wiring
Comprehensive instruction manual for the MYPIN D Series Intelligent Sensor Meter. Covers specifications, operation, parameter setting, wiring diagrams, and troubleshooting for models like DM8A, DK8A, and DM8E.
Preview Manwal ta' Istruzzjoni tal-Miter tal-Enerġija ta' Fażi Unika tas-Serje MYPIN DW - Gwida Teknika
Manwal ta' struzzjonijiet komprensiv għall-miter tal-enerġija monofażiku tas-Serje MYPIN DW. Ikopri l-ispeċifikazzjonijiet, it-tħaddim, id-dijagrammi tal-wajers, is-settings tal-parametri, u l-applikazzjonijiet għal kejl elettriku preċiż.
Preview Manwal tal-Istruzzjonijiet tal-Kontrollur tal-Użin tas-Serje MYPIN LM u Istruzzjonijiet għall-Utent tal-Modbus
Gwida komprensiva għall-Kontrollur tal-Użin tas-Serje MYPIN LM, li tkopri l-installazzjoni, it-tħaddim, is-settings tal-parametri, u l-protokolli ta' komunikazzjoni Modbus. Tinkludi speċifikazzjonijiet dettaljati, informazzjoni dwar l-ordnijiet, u dimensjonijiet tal-immuntar.
Preview Miters Intelliġenti tas-Serje MYPIN FH: Frekwenza, Tako, Għadd, Batch - Speċifikazzjonijiet Tekniċi
Speċifikazzjonijiet tekniċi komprensivi, karatteristiċi, u modi operattivi għall-miters intelliġenti tas-serje MYPIN FH, inklużi l-funzjonijiet tal-frekwenza, tat-tako, tal-għadd, u tal-lott. Dan id-dokument jagħti dettalji dwar id-dimensjonijiet, il-parametri, u d-dijagrammi tal-konnessjoni.
Preview Manwal tal-Istruzzjonijiet tal-Counter/Tul/Miter tal-Lott tas-Serje MYPIN FH
Manwal ta' struzzjonijiet għas-Serje MYPIN FH ta' Miters tal-Kontatur, tat-Tul, u tal-Lott. Ikopri l-ispeċifikazzjonijiet, il-karatteristiċi, l-ordnijiet, it-tħaddim, il-modi ta' input/output, u l-konnessjonijiet tat-terminals għall-mudelli FH4, FH7, u FH8.
Preview MYPIN FH/FC Series Counter Diġitali u Miter tat-Tul - Speċifikazzjonijiet u Manwal
Manwal komprensiv għall-counters diġitali u l-meters tat-tul tas-Serje MYPIN FH/FC. Dettalji dwar l-ispeċifikazzjonijiet, il-kodiċijiet tal-ordnijiet, it-tħaddim, is-settings tal-parametri, u l-konnessjonijiet tat-terminals għall-mudelli FH4, FH6, FH7, FH8, FH9, FH10.