1. Introduzzjoni
The SINOTIMER TM919B is a robust 30A programmable digital timer switch designed for automatic control of various electrical equipment. This DIN rail-mounted device offers 7-day, 24-hour programming capabilities, allowing users to set up to 16 distinct ON/OFF programs daily or weekly. It is an ideal solution for managing the operation of street lamps, neon lights, signs, general lighting, water heaters, air conditioners, billboards, rice cookers, superchargers, sprayers, bottling machines, preheaters, agricultural facilities, and broadcasting equipment. The timer switch incorporates a 1.2V/40mA rechargeable battery to retain programmed settings during power outages, ensuring reliable operation. Key features include low power consumption, a high-precision CMOS chip, strong anti-interference capabilities, and a user-friendly setup process.
2. Informazzjoni dwar is-Sigurtà
- Always disconnect power at the main circuit breaker before attempting any installation, wiring, or maintenance.
- Installation should be performed by a qualified electrician or an individual with a thorough understanding of electrical systems.
- Ensure all wiring adheres to local and national electrical codes and regulations.
- Do not exceed the maximum load rating of 30A for the timer switch. Overloading can cause damage to the device and create a fire hazard.
- Żomm l-apparat 'il bogħod mill-ilma, umdità, u temperaturi estremi.
- Tippruvax tiftaħ jew issewwi l-apparat int stess. Irreferi għal kull manutenzjoni f'idejn persunal kwalifikat.
3. Kontenut tal-Pakkett
- 1 x SINOTIMER TM919B Digital Timer Switch
- 1 x Manwal għall-Utent
4. Prodott Aktarview u Kontrolli
Familiarize yourself with the components and controls of your TM919B timer switch:

Buttuni tal-Kontroll:
- P (Programm): Enters program setting mode. Press repeatedly to cycle through ON/OFF settings.
- D+ (Jum): Adjusts the day of the week or program day.
- H+ (Siegħa): Adjusts the hour for current time or program time.
- M+ (Minuta): Adjusts the minute for current time or program time.
- RESET: Clears all settings and resets the timer to factory defaults.
- MANWAL: Toggles between ON, AUTO, and OFF modes.
Indikaturi tal-Wiri:
- Th: Indicates Thursday (example, will show current day).
- AM/PM: Time format indicator.
- ON/AUTO/OFF: Current operating mode.
- ON (Red LED): Indicates the timer output is currently ON.
5. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Mudell | TM919B |
| Provvista tal-Enerġija | AC220V, 50 / 60Hz |
| Kapaċità tat-Tagħbija | 30A (Tagħbija Reżistiva) |
| Swiċċ Kuntatt | 1 Change-over Switch |
| Avvenimenti programmabbli | 16 ON/OFF programs per day or week |
| Intervall Minimu | 1 minuta |
| Medda ta' Żmien | Minuta sa 168 siegħa (7 ijiem) |
| Batterija Interna | 1.2V/40mA rechargeable (for program retention) |
| Eżattezza | ≤1s/24h at 25°C |
| Materjal | ABS + Komponenti Elettroniċi |
| Kulur | Abjad |
Dimensjonijiet:

- Quddiem View: 3.5cm (width) x 8.7cm (height)
- Ġenb View: 6.5cm (depth) x 4.7cm (top width) x 4.5cm (main body height) x 3cm (DIN rail clip height)
6. Installazzjoni
The TM919B timer switch is designed for DIN rail mounting. Ensure the DIN rail is securely installed in a suitable enclosure.
Dijagramma tal-Wiring:
Refer to the diagram below for proper wiring. Always ensure power is disconnected before making any electrical connections.

- Input ta' Enerġija: Connect the Live (L) wire to terminal 1 and the Neutral (N) wire to terminal 2. The timer requires AC220V power.
- Konnessjonijiet tal-Ħruġ: The timer has a single change-over switch output.
- Terminal 4: Common (COM) output.
- Terminal 3: Normally Open (NO) contact. This contact closes when the timer is ON.
- Terminal 5: Normally Closed (NC) contact. This contact opens when the timer is ON.
- Konnessjoni tat-Tagħbija: For loads up to 30A, you can directly connect your appliance to the appropriate output terminals (e.g., L to terminal 4, appliance to terminal 3, and appliance to N). For higher inductive loads or loads exceeding 30A, it is highly recommended to use an external contactor (as shown in Figure 3) to protect the timer's internal relay.
7. Twaqqif u Programmazzjoni
7.1 Initial Setup / Reset
- Upon first power-up or after a long period of no power, the display may be blank. The internal battery will charge once power is applied.
- Agħfas il- RESET button (usually a small recessed button, use a pointed object like a pen tip) to clear all previous settings and reset the timer. The display will show "0:00" and "AUTO".
7.2 Issettjar tal-Ħin Kurrenti
- Agħfas il- D+ buttuna biex tissettja l-ġurnata kurrenti tal-ġimgħa.
- Agħfas il- H+ buttuna biex tissettja s-siegħa kurrenti.
- Agħfas il- M+ buttuna biex tissettja l-minuta kurrenti.
- The time will automatically save after a few seconds of inactivity.
7.3 Programmazzjoni taċ-Ċikli ON/OFF
The TM919B allows for up to 16 ON and 16 OFF programs. Each program consists of a specific time and day(s) for the timer to switch ON or OFF.
- Agħfas il- P button once. The display will show "1 ON" (for the first ON program).
- Agħfas D+ to select the day(s) for this program. Options include: every day, specific weekdays, weekends, etc.
- Agħfas H+ to set the hour for the "1 ON" program.
- Agħfas M+ to set the minute for the "1 ON" program.
- Agħfas P again. The display will show "1 OFF" (for the first OFF program).
- Repeat steps 2-4 to set the day(s), hour, and minute for the "1 OFF" program.
- Kompli agħfas P to cycle through "2 ON", "2 OFF", up to "16 ON", "16 OFF", setting each as needed.
- If you don't need all 16 programs, simply stop pressing P after setting your desired programs. The timer will exit programming mode after about 10 seconds of inactivity.
- To exit programming mode at any time, press the MANWAL buttuna.
8. Istruzzjonijiet Operattivi
Once programmed, the timer will operate automatically according to your settings. The current operating mode is displayed on the LCD screen (ON, AUTO, or OFF).
Override manwali:
Il- MANWAL button allows you to temporarily override the programmed schedule without deleting it. Pressing the MANWAL button cycles through the following modes:
- FUQ: The output is forced ON, regardless of the program.
- AUTO: It-tajmer jaħdem skont l-iskeda pprogrammata.
- MITFI: The output is forced OFF, regardless of the program.
To return to automatic operation, press the MANWAL button until "AUTO" is displayed.
9. Manutenzjoni
- Keep the timer switch clean and dry. Use a soft, dry cloth to wipe the exterior.
- Tużax tindif jew solventi li joborxu.
- Żgura ventilazzjoni xierqa madwar l-apparat biex tevita sħana żejda.
- The internal rechargeable battery is designed for long-term use and typically does not require replacement during the product's lifespan.
- There are no user-serviceable parts inside the unit. Any unauthorized opening or modification will void the warranty.
10 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Id-displej huwa vojt jew mudlam. | No power supply or internal battery discharged. | Check power connections. If power is present, allow time for the internal battery to charge (up to 4 hours). |
| Timer is not switching ON/OFF as programmed. | Incorrect program settings, manual override engaged, or incorrect current time. | Verify all ON/OFF programs are set correctly. Ensure the timer is in "AUTO" mode (press MANUAL button until "AUTO" is displayed). Check that the current day and time are set accurately. |
| L-output huwa dejjem ON jew dejjem OFF. | Override manwali attivat. | Agħfas il- MANWAL button until "AUTO" is displayed on the screen. |
| Appliance connected to timer is not working. | Appliance fault, incorrect wiring, or timer output not active. | Test the appliance directly. Verify wiring connections (refer to Section 6). Check timer mode and program. Ensure the load does not exceed 30A. |
11. Għajnuniet għall-Utenti
- For Inductive Loads: If connecting motors, fans, or other inductive loads, consider using an external contactor. This will protect the timer's internal relay from high inrush currents and extend its lifespan.
- Ivverifika l-Wiring: Always double-check your wiring connections against the provided diagram before applying power to prevent damage to the timer or connected appliances.
- Test Programs: After programming, use the MANWAL button to cycle the output ON and OFF to quickly verify your wiring and ensure the connected appliance responds as expected, without waiting for the scheduled time.
- Qawwa Outage Protezzjoni: The built-in rechargeable battery ensures your programs are retained during power outages. However, for extended outages, the battery may discharge, requiring you to reset the time.
12. Garanzija u Appoġġ
For technical assistance, warranty claims, or product support, please contact your original retailer or the manufacturer directly. Please have your product model number (TM919B) and proof of purchase readily available when seeking support.