1. Introduzzjoni
This manual provides essential information for the proper setup, operation, and maintenance of your OWON Digital Oscilloscope Probes. These probes are designed for use with compatible OWON digital oscilloscopes, including the 3000 series and HDS2000 series models such as XDS3202E, XDS2102A, HDS2102S, and HDS2202S.
The probes are available in various bandwidths: OW3200 (200MHz), OW3100 (100MHz), and OW3070 (70MHz).
2. Kontenut tal-Pakkett
Jekk jogħġbok ivverifika li l-oġġetti kollha huma preżenti u f'kundizzjoni tajba meta tiftaħ il-pakkett.
- OWON Digital Oscilloscope Probe(s) (model and quantity as purchased)
- Ground lead with alligator clip
- Adjustment tool (if applicable)
- Instruction leaflet (if included)



Image: Various OWON Digital Oscilloscope Probes.
3. Istruzzjonijiet ta' Setup
- Kontroll tal-Kompatibbiltà: Ensure your oscilloscope is compatible with the probe's bandwidth and connector type (BNC). These probes are designed for OWON 3000 series and HDS2000 series oscilloscopes.
- Connect to Oscilloscope: Carefully align the probe's BNC connector with the input channel of your oscilloscope. Push and twist clockwise until it locks securely.
- Attach Ground Lead: Connect the alligator clip of the probe's ground lead to the ground terminal of your circuit under test. A secure ground connection is crucial for accurate measurements and safety.
- Set Attenuation: Most oscilloscope probes have a switch for attenuation (e.g., 1X, 10X). Set this switch according to your measurement needs. Remember to match the oscilloscope's channel setting to the probe's attenuation (e.g., if the probe is set to 10X, the oscilloscope channel should also be set to 10X).
- Probe Compensation (if applicable): If your probe has a compensation adjustment, connect the probe to the oscilloscope's probe compensation output (usually a square wave signal). Adjust the probe's compensation trimmer until the square wave displayed on the oscilloscope is flat-topped, without overshoot or undershoot.
4. Istruzzjonijiet Operattivi
Once the probe is properly set up, you can begin taking measurements.
- Connect to Test Point: Carefully connect the probe tip to the desired test point in your circuit. Ensure stable contact.
- Observe Waveform: Adjust the vertical and horizontal scales on your oscilloscope to properly view il-forma tal-mewġ.
- Prekawzjonijiet tas-Sigurtà: Always observe safety guidelines when working with electrical circuits. Do not exceed the maximum input voltage rating of the probe or oscilloscope.
5. Manutenzjoni
- Tindif: Use a soft, dry cloth to clean the probe body. For the probe tip and connector, use a cotton swab lightly dampened with isopropyl alcohol if necessary. Ensure no liquid enters the probe body.
- Ħażna: Store probes in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid bending or kinking the cable excessively.
- Spezzjoni: Periodically inspect the probe cable for any signs of damage, such as cuts or fraying. Check the BNC connector for corrosion or bent pins.
6 Issolvi l-problemi
- No Signal Displayed:
- Check if the probe is securely connected to both the oscilloscope and the circuit.
- Ensure the oscilloscope channel is enabled and properly configured.
- Verify the ground lead is firmly connected.
- Distorted or Unstable Waveform:
- Check probe compensation (if applicable) and adjust as needed.
- Ensure the probe's attenuation setting matches the oscilloscope's channel setting.
- Verify the probe tip and ground lead have good contact with the circuit.
- Check for external interference or noise in the test environment.
- Vol mhux korretttage Qari:
- Double-check the probe's attenuation setting and the oscilloscope's vertical scale.
- Perform probe compensation if not already done.
7. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Isem tad-Ditta | OWON |
| Numri tal-Mudell | OW3200, OW3100, OW3070 |
| Bandwidth | OW3200: 200MHz, OW3100: 100MHz, OW3070: 70MHz |
| Max Waveform Capture Rate | 30,000 wfm/s |
| Batterija Inkluża | Nru |
| Battery Demountable | Nru |
| Kategorija tal-Provvisti DIY | Elettriku |
| Ċertifikazzjoni | CE |
| Oriġini | Iċ-Ċina kontinentali |
Dimensjonijiet tal-pakkett:
- Tul: 12 ċm
- Wisa ': 12 ċm
- Għoli: 12 ċm
- Piż: 0.28 kg
8. Għajnuniet għall-Utenti
- Verify Model: Always confirm the specific model (OW3200, OW3100, or OW3070) and its corresponding bandwidth to ensure it matches your measurement requirements and oscilloscope capabilities.
- Grounding kif suppost: A stable and low-impedance ground connection is critical for accurate measurements and to prevent noise pickup.
- Attenuation Matching: Ensure the attenuation setting on the probe (e.g., 1X, 10X) is correctly matched on the oscilloscope's input channel to get accurate voltage qari.
9. Garanzija u Appoġġ
For warranty information, technical support, or service inquiries, please contact the seller or the manufacturer directly. The seller for this product is Shenzhen Shengtai Tools Mall.
Jekk jogħġbok żomm il-prova tax-xiri tiegħek għal kwalunkwe talba ta' garanzija.