Hilitand WEL3005

WEL3005 Electronic Load Module Instruction Manual

Model: WEL3005 | Brand: Hilitand

1. Introduzzjoni

The Hilitand WEL3005 Electronic Load Module is a multifunctional device designed for various electrical testing applications, including power aging tests and battery discharge. Featuring a color display, adjustable constant current, and multiple protection functions, it provides clear readings and reliable performance for both professional and DIY electrical projects.

2. Informazzjoni dwar is-Sigurtà

  • Always ensure the module's supply voltage is within the specified range of 6V-30V.
  • Do not exceed the maximum discharge power of 30W to prevent damage to the device.
  • Verify correct wiring connections before applying power to avoid short circuits or incorrect measurements.
  • Operate the module within the recommended working temperature range of -10°C to +75°C.
  • Żomm l-apparat 'il bogħod mill-umdità u minn temperaturi estremi.
  • In case of overheating (above 75°C), the module's overheat protection will activate. Allow the device to cool down before resuming operation.

3. Prodott Aktarview

The WEL3005 Electronic Load Module features a compact design with an integrated fan for cooling and a color display for real-time data monitoring.

3.1 Komponenti u Kontrolli

WEL3005 Electronic Load Module front view
Figura 1: Quddiem view of the WEL3005 Electronic Load Module.
WEL3005 Electronic Load Module with labeled controls
Figure 2: Labeled components of the WEL3005 module, including P1, SET, P2 buttons, rotary encoder, and LOCK button.
  • Display bil-kulur: Provides clear readings of voltage, current, power, capacity, energy, resistance, and temperature.
  • P1 Button: Switches to P1/P2 interface.
  • Buttuna SET: Jaċċessa l-menu tal-issettjar.
  • P2 Button: Switches to P1/P2 interface.
  • Rotary Encoder (On/off key and adjustment data): Used to turn the device on/off and adjust parameters.
  • Buttuna LOCK: For internal resistance measurement.
  • Fann li jkessaħ: 4010 Double Roller Fan, Speed 8000, activates above 45°C.
  • Terminali tal-Wiring: Marked B+B- for measuring voltage u kurrenti.
Wara view of the WEL3005 Electronic Load Module showing fan and wiring terminals
Figura 3: Wara view showing the cooling fan and wiring terminals.

4. Speċifikazzjonijiet

Karatteristika Speċifikazzjoni
Mudell WEL3005
Tip ta' Oġġett Electronic Load Module
Volum tal-Provvista tal-Modulutage 6V-30V
Vol. tal-kejltage 0-30V
Kurrent ta' Skarigu 0A-5A Continuously Adjustable
Qawwa ta' Kwittanza Up to 30W (Note: Do not use super power!!)
Temperatura tax-Xogħol -10°C ~ +75°C
Resolution (Voltage) 0.01V
Resolution (Current) 0.001A
Eżattezza (Voltage) 1% ± 1 ċifra
Preċiżjoni (kurrent) 1% ± 1 ċifra
Undervoltage Protezzjoni Iva (1.5-30V)
Protezzjoni fuq il-Qawwa Iva (1-30W)
Protezzjoni mis-sħana żejda Yes (Fan starts > 45°C, Protection > 75°C)
Input Anti-Reverse Iva
Fan 4010 Double Roller Fan, Speed 8000
Daqs tal-Modulu Madwar 79 x 43 x 70mm / 3.1 x 1.7 x 2.8 pulzieri
Hole Opening Size Approx. 76 x 39mm / 3 x 1.5in

5. Istruzzjonijiet ta' Setup

5.1 Wiring the Module

The WEL3005 module requires careful wiring to ensure proper operation and accurate measurements. Refer to the diagram below for correct connections.

Wiring diagram for WEL3005 Electronic Load Module
Figure 4: Wiring diagram. Small screen printing B+B- for measuring voltage, large screen printing B+B- for measuring current.
  • Provvista tal-Enerġija: Connect a 6V-30V DC power source to the module's supply input.
  • Konnessjoni tat-Tagħbija:
    • Connect the positive terminal of the device under test (e.g., battery) to the "B+" terminal for current measurement.
    • Connect the negative terminal of the device under test to the "B-" terminal for current measurement.
    • Tiżgura l-voltage measurement leads are connected to the appropriate B+ and B- terminals for voltagsensing.
  • The module features input anti-reverse protection, but always double-check polarity before powering on.

5.2 Qawwa Inizjali

  • After wiring, turn on the module using the rotary encoder.
  • The color display will illuminate, showing current readings and status.
  • The fan will automatically start if the internal temperature exceeds 45°C.

6. Istruzzjonijiet Operattivi

6.1 Adjusting Discharge Current

  • Use the rotary encoder to continuously adjust the discharge current from 0A to 5A.
  • Rotate clockwise to increase current, counter-clockwise to decrease.
  • Observe the display for real-time current values.

6.2 Parametri ta' Monitoraġġ

The color display shows the following parameters:

  • Voltage (U)
  • Kurrent (I)
  • Qawwa (P)
  • Kapaċità (Ah)
  • Enerġija (Wh)
  • Reżistenza (R)
  • Temperatura (T)

6.3 Funzjonijiet ta' Protezzjoni

The module is equipped with several protection features:

  • Undervoltage Protezzjoni: Activates if the voltage drops below the set threshold (1.5-30V).
  • Over Power Protection: Engages if the discharge power exceeds the set limit (1-30W).
  • Protezzjoni mis-sħana żejda: The fan starts at 45°C, and protection activates if the temperature reaches 75°C.

6.4 Setting Menu (SET Button)

Press the SET button to enter the configuration menu. Use the rotary encoder to navigate and adjust settings such as undervoltage limits and overpower limits. Press SET again to confirm changes or exit the menu.

6.5 Internal Resistance Measurement (LOCK Button)

Use the LOCK button for specific internal resistance measurement functions. Refer to the on-screen prompts or detailed operational guides for this advanced feature.

7. Manutenzjoni

  • Żomm il-modulu nadif u ħieles mit-trab. Uża drapp artab u niexef għat-tindif.
  • Ensure the cooling fan is not obstructed to maintain efficient heat dissipation.
  • Store the device in a dry environment within the specified working temperature range when not in use.
  • Avoid dropping or subjecting the module to strong impacts.

8 Issolvi l-problemi

Problema Kawża Possibbli Soluzzjoni
Il-modulu ma jixgħelx. Provvista ta' enerġija mhux korretta voltage or polarity; loose connection. Verify power supply is 6V-30V and correctly connected. Check all wiring.
No current discharge. Load not connected correctly; current setting is 0A; undervoltage/overpower protection active. Check load wiring. Increase current setting. Check for protection warnings on display.
Il-modulu jisħon iżżejjed. Fan obstructed; operating in high ambient temperature; exceeding 30W discharge power. Ensure fan is clear. Operate in a cooler environment. Reduce discharge power.
Qari mhux preċiż. Loose connections; faulty test leads; external interference. Check all connections. Use high-quality test leads. Minimize electrical interference.

9. Għajnuniet għall-Utenti

  • When testing batteries, ensure the battery type and capacity are suitable for the discharge current and power settings to avoid damage.
  • For precise measurements, allow the module to stabilize for a few minutes after power-on before taking readings.
  • Il-wiri bil-kulur jipprovdi ħarsa komprensiva lejnview; familiarize yourself with all displayed parameters for effective monitoring.
  • Consider using external cooling if operating at the upper limits of power or temperature for extended periods.

10. Garanzija u Appoġġ

This product is designed for durability and accuracy. For technical support or warranty inquiries, please contact the manufacturer or your point of purchase. Keep your purchase receipt as proof of purchase.