CHX-302B, CHX-307A, CHX-319A CHX-302B, CHX-307A, CHX-319A

User Manual: Fog Machine Motherboard

Models: CHX-302B, CHX-307A, CHX-319A Series

1. Introduzzjoni

This manual provides detailed instructions for the installation, operation, and maintenance of the CHX-302B, CHX-307A, and CHX-319A series fog machine motherboards. These boards are designed for 1500W and 3000W remote control fog machines, featuring constant temperature electronic control and DMX capabilities for professional stagapplikazzjonijiet elettroniċi u DJ.

2. Avviżi Importanti dwar is-Sigurtà

  • Installazzjoni Professjonali Rakkomandata: Installation of this motherboard requires technical knowledge of electronics and fog machine systems. If you are unsure, seek professional assistance.
  • Kompatibilità: Ensure that the replacement motherboard is 100% identical to your old machine board. Incompatible parts may lead to malfunction or damage.
  • Sors tal-Enerġija: Always disconnect the fog machine from the main power supply before attempting any installation, maintenance, or troubleshooting.
  • Immaniġġjar tal-komponenti: Electronic components are sensitive to static discharge. Handle the motherboard and other parts with care, preferably using anti-static precautions.
  • Magnetic/Battery Components: Be aware that certain shipping methods may not accept magnetic or battery components. Ensure all parts are handled and stored appropriately.

3. Komponenti Inklużi

Depending on the specific model purchased, your package may include the following components:

  • Main Control Motherboard (e.g., CHX-302B, CHX-307A, CHX-319A)
  • Unità ta' Kontroll mill-bogħod
  • Display Board (LCD or Digital Segment Display)
  • DMX DIP Switch Board (for DMX-compatible models)
  • Connecting Cables/Wiring Harnesses
Fuqview of fog machine motherboard components including main board, LCD display, remote control, and wiring.
Figure 3.1: Typical components included with the fog machine motherboard.
CHX-319A type motherboard with DMX DIP switch and remote control.
Figure 3.2: CHX-319A type motherboard with DMX DIP switch and remote.
CHX-307A type motherboard with LCD display and remote control.
Figure 3.3: CHX-307A type motherboard with LCD display and remote.
CHX-302B type motherboard with digital display and remote control.
Figure 3.4: CHX-302B type motherboard with digital display and remote.

4. Speċifikazzjonijiet

Karatteristika Speċifikazzjoni
Numri tal-Mudell CHX-302B, CHX-307A, CHX-319A (SP001)
Tip ta' Oġġett StagEffett tad-Dawl e
Okkazjoni Professjonali Stage & DJ
Qawwa (W) 1500W (kompatibbli wkoll ma' sistemi ta' 3000W)
Voltage 90-240V AC
Vol nominalitage Other (AC)
Sors tal-Enerġija AC
Huwa Basal Inklużi Nru
Fluss Luminuż <60
Kimika ta' tħassib kbir Xejn
Metodu ta 'Installazzjoni Self-contained
Ċertifikazzjoni CE
Oriġini Iċ-Ċina kontinentali
Piż tal-Pakkett 0.3 kg
Dimensjonijiet tal-Pakkett (L x W x H) 10 ċm x 10 ċm x 20 ċm

5. Installazzjoni u Wiring

Before beginning installation, ensure the fog machine is unplugged from all power sources. Refer to the wiring diagram below for correct connections. Incorrect wiring can damage the motherboard or the fog machine.

  1. Neħħi l-Bord il-Qadim: Carefully disconnect all wires from the existing fog machine motherboard and remove it from the chassis. Note the position of each wire.
  2. Immonta Bord Ġdid: Secure the new motherboard in the designated position within the fog machine chassis.
  3. Qabbad l-Input tal-Enerġija: Connect the main AC power input wires to the 'Input' terminals on the new motherboard.
  4. Connect Heater and Pump: Connect the heater and pump wires to their respective terminals as indicated on the board.
  5. Connect Thermocouple: Attach the thermocouple wires to the 'thermocouple' port for temperature sensing.
  6. Connect Display Board: Connect the display board (LCD or digital) to the 'display board' port using the provided ribbon cable.
  7. Connect Hand Control/Wireless Module: If applicable, connect the hand control or wireless receiver module to their designated ports.
  8. Connect DMX (if applicable): For DMX-compatible models, connect the DMX input/output to the 'DMX' terminals. Set the DMX address using the DIP switches on the DMX board (see Figure 5.2).
  9. Connect BGR LED (if applicable): If your fog machine includes BGR LEDs, connect them to the 'BGR LED' output.
  10. Qabbad il-Ħruġ tal-Enerġija: Connect any additional power outputs as required by your fog machine model.
Detailed wiring diagram for the fog machine motherboard, showing connections for DMX, BGR LED, power output, hand control, wireless, display board, thermocouple, pump, heater, and input.
Figure 5.1: Motherboard wiring diagram with labeled connection points.
Close-up of a DMX DIP switch board with switches labeled 1 through 8 and an ON position.
Figure 5.2: DMX DIP switch for setting DMX addresses.

6. Operazzjoni

Once the motherboard is correctly installed and wired, you can operate your fog machine using the display board, remote control, or DMX (if configured).

6.1. Display Board Operation (LCD Type)

Close-up of an LCD display board with MENU, UP, DOWN, TIMER, LOCK, and MANUAL buttons.
Figure 6.1: LCD Display Board.
  • MENU: Accesses settings and parameters.
  • FUQ ISFEL: Innaviga fl-għażliet tal-menù jew aġġusta l-valuri.
  • TIMER: Activates or adjusts timed fog output.
  • LOCK: Jissakkar is-settings attwali biex jipprevjeni bidliet aċċidentali.
  • MANWAL: Initiates manual fog output.

6.2. Display Board Operation (Digital Segment Type)

Close-up of a digital segment display board with four control buttons.
Figure 6.2: Digital Segment Display Board.

The digital display board typically features a 4-digit display and several buttons for basic control and DMX address setting. Consult your fog machine's specific manual for detailed button functions.

6.3. Operazzjoni ta 'Kontroll mill-Bogħod

The remote control allows for wireless operation of the fog machine. Common buttons include:

  • A: Often used for continuous fog output or a specific function.
  • B: May control timed output or another specific function.
  • C: Typically used to stop fog output or clear settings.
  • D: May activate a burst of fog or another special effect.

Refer to your specific remote control's instructions for exact button assignments.

6.4. Kontroll DMX

If your motherboard is DMX-compatible, you can control the fog machine via a DMX controller. Ensure the DMX address is correctly set using the DIP switches (refer to Figure 5.2 and your DMX controller's manual for addressing schemes). The DMX channels typically control fog output, duration, and fan speed.

7. Manutenzjoni

  • Tindif: Keep the motherboard and surrounding area free from dust, debris, and fog fluid residue. Use a soft, dry brush or compressed air for cleaning.
  • Konnessjonijiet: Iċċekkja l-konnessjonijiet tal-wajers kollha perjodikament biex tiżgura li huma sikuri u ħielsa mill-korrużjoni.
  • Ħażna: If the fog machine is not in use for an extended period, store it in a dry, cool environment.
  • Kwalità tal-Fluwidu: Always use high-quality, compatible fog fluid to prevent clogging and damage to the heating element and pump, which can indirectly affect the motherboard's performance.

8 Issolvi l-problemi

Problema Kawża Possibbli Soluzzjoni
No Power to Board Loose power connection, faulty power supply, blown fuse. Check all power connections. Inspect the power supply and fuses. Ensure the main power cable is securely plugged in.
Fog Machine Not Heating Faulty heater connection, thermocouple issue, motherboard fault. Verify heater and thermocouple connections. If connections are good, the heater or motherboard may be faulty.
No Fog Output (Heated) Pump not working, clogged nozzle, empty fluid tank. Check pump connections. Ensure fluid tank is full. Clean or replace nozzle if clogged.
Il-Kontroll Remot Mhux Jaħdem Dead battery, remote not paired, faulty receiver. Replace remote battery. Refer to your fog machine's manual for remote pairing instructions. Check receiver connection to motherboard.
Kwistjonijiet ta' Kontroll tad-DMX Incorrect DMX address, faulty DMX cable, DMX controller issue. Verify DMX address settings on the DIP switches. Check DMX cable for damage. Test with a different DMX controller if possible.
Display Board Not Working Loose connection, faulty display board. Check the ribbon cable connection to the motherboard. If still not working, the display board may need replacement.

9. Għajnuniet għall-Utenti

  • DMX Address Configuration: For DMX control, carefully parameterize the DMX address using the DIP switches. A common request from users is for a detailed handout on DMX addressing; ensure you understand binary conversion for DIP switch settings.
  • Ivverifika l-Kompatibbiltà: Always double-check that the new motherboard is an exact match for your old board to avoid compatibility issues and ensure proper functionality.
  • Wiring Documentation: Before disconnecting any wires from your old board, take photos or make a diagram of the existing connections. This will greatly assist in installing the new board.

10. Garanzija u Appoġġ

For any technical support or warranty inquiries, please contact the seller or manufacturer directly. Provide your purchase details and a clear description of the issue to facilitate a quicker resolution.

The manufacturer is Mingjun Stage Equipments Accessories Store.

Dokumenti Relatati - CHX-302B, CHX-307A, CHX-319A

Preview Manwal tal-Utent u Istruzzjonijiet tas-Sigurtà tal-Martell Rotatorju Mingħajr Fili Milwaukee M18 CHX
Manwal komprensiv għall-utent għall-Milwaukee M18 CHX Cordless Rotary Hammer, li jkopri l-ispeċifikazzjonijiet tekniċi, il-linji gwida tas-sigurtà, l-istruzzjonijiet għat-tħaddim, il-manutenzjoni, u s-soluzzjoni tal-problemi għal użu professjonali.
Preview Heparin Protocol Guide for Hospital Nurses using Oracle Health PowerChart
This guide details the Heparin Protocol for hospital nurses, covering ordering, pharmacy processes, starting the drip, PTT monitoring, titration, and discontinuation within the Oracle Health PowerChart and FirstNet EDUCATION EHR systems.
Preview Lithonia Lighting Outdoor & Area Lighting Catalog
Explore Lithonia Lighting's comprehensive range of outdoor and area lighting solutions, featuring architectural designs, high-performance optics, and durable construction for various applications.
Preview Gwida tar-Riżorsi tal-Istartjar mill-Bogħod ta' Staub Electronics 2022-2023 | Compustar, Drone, iDatalink, Maestro
Gwida komprensiva tar-riżorsi minn Staub Electronics għall-2022-2023, li tinkludi sistemi ta' startjar mill-bogħod Compustar, Drone, iDatalink, u Maestro, sigurtà, telematika, kameras fil-karozza, u soluzzjonijiet ta' integrazzjoni tal-awdjo.
Preview Gwida tar-Riżorsi tal-Istartjar mill-Bogħod ta' Staub Electronics 2022-2023
Gwida komprensiva tar-riżorsi minn Staub Electronics għall-2022-2023, li tinkludi prodotti Compustar, Drone, Firstech, Momento, iDatalink, u Maestro inklużi sistemi ta' startjar mill-bogħod, kontrolluri tas-sigurtà, telematiċi, kameras fil-karozza, integrazzjoni awdjo, u kits ta' integrazzjoni speċifiċi għall-vettura.
Preview Weelko B-System Multifunctional Tower: Technical Overview, Components, and Specifications
Tekniku komprensiv fuqview of the Weelko B-System multifunctional beauty treatment tower (Ref. 3021), detailing its components, functions, assembly instructions, and technical specifications for professional use.