1. Introduzzjoni
This manual provides detailed instructions for the installation, operation, and maintenance of your Sinotimer Digital Analogue DIN Module Time Switch. This device is designed for industrial applications, offering precise 24-hour programmable timing with a large LCD display and backlight functionality.
2. Funzjonijiet tal-Prodott
- Clock display (24-hour format).
- Programmable Timer with up to 96 ON/OFF programs per day.
- Backlight feature: The backlight illuminates when the timer is off and automatically disappears after 5 seconds.
3. Speċifikazzjonijiet
| Parametru | Valur |
|---|---|
| Numri tal-Mudell | TM929AKL (16A), TM929BKL (30A) |
| Provvista tal-Enerġija | 85 ~ 265VAC, 50/60Hz |
| Kurrent Massimu tat-Tagħbija tal-Ħruġ | 16A / 30A (depending on model) |
| Programmi | Sa 96 ON/OFF kuljum |
| Firxa tal-issettjar | 15 minuta sa 24 sigħat |
| Minimum Setting Interval | minuti 15 |
| Wiri | LCD b'dawl ta 'wara |
| Dimensjonijiet | 86.5mm x 36mm x 68.5mm |
| Installazzjoni | Ferrovija DIN ta '35mm |
| Batterija | TM929AKL (16A): Replaceable CR2032; TM929BKL (30A): Non-replaceable internal battery |
| Konsum tal-Enerġija | <5VA |
| Black-out (Power Reserve) | 90-il jum |
| Ċertifikazzjoni | CE |
Nota: The TM929AKL (16A) model features a replaceable CR2032 battery, while the TM929BKL (30A) model has a non-replaceable internal battery. Wiring diagrams differ between models.

4. Setup
4.1 Installazzjoni
The time switch is designed for mounting on a standard 35mm DIN rail. Ensure the mounting location is dry, well-ventilated, and free from excessive vibrations or extreme temperatures.

4.2 Wajers
TWISSIJA: All wiring should be performed by a qualified electrician and in accordance with local electrical codes. Ensure power is disconnected before attempting any wiring.
The timer has terminals for Line (L), Neutral (N), and output contacts (NO, NC, Common). Refer to the diagrams below for typical wiring configurations.


4.3 L-Inizjali tal-Ixgħel
Once wired correctly, apply power to the device. The LCD will illuminate and display the current time. If the display is blank, check the power supply and, for the 16A model, ensure the CR2032 battery is correctly installed.
5. Istruzzjonijiet Operattivi
The timer features a MENU button, UP/DOWN arrow buttons, an OK button, and a Reset (Res) button.

5.1 Issettjar tal-Ħin Kurrenti
- Press the 'MENU' button.
- Use the 'UP' and 'DOWN' arrow buttons to adjust the hour and minute.
- Press 'OK' to confirm each setting.
- Press 'MENU' again to return to the clock display.
5.2 Programmazzjoni taċ-Ċikli ON/OFF
The timer supports up to 96 ON/OFF programs. Each program can be set for specific days of the week.
- Press the 'MENU' button to enter programming mode. The display will show '00:00' or a program number.
- Use 'UP' and 'DOWN' to set the desired ON time (hour and minute). Press 'OK' to confirm.
- Next, set the desired OFF time (hour and minute). Press 'OK' to confirm.
- Use 'UP' and 'DOWN' to select the days of the week for this program (e.g., Mon-Fri, Sat-Sun, or individual days). Press 'OK' to confirm.
- Repeat steps 2-4 for additional programs.
- Press 'MENU' to exit programming mode and save settings.
5.3 Manwal Override
To manually switch the timer's output, press the 'OK' button. This will cycle through the modes: ON (always on), AUTO (follows programmed schedule), and OFF (always off).
6. Manutenzjoni
6.1 Battery Replacement (TM929AKL 16A only)
The TM929AKL (16A) model uses a replaceable CR2032 battery. If the display becomes dim or the time settings are lost frequently during power outages, the battery may need replacement. Carefully open the battery compartment and replace the CR2032 battery, ensuring correct polarity. The TM929BKL (30A) model has a non-replaceable internal battery.
6.2 Kura Ġenerali
Keep the device clean and dry. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents. Ensure the protective cover is closed to prevent dust and moisture ingress.
7 Issolvi l-problemi
- Il-wiri huwa vojt: Check the main power supply. For the 16A model, check the CR2032 battery.
- Timer not switching: Verify wiring connections are secure and correct. Ensure the timer is in 'AUTO' mode. Check that programs are set correctly and not conflicting.
- Incorrect time: Reset the timer using the 'Res' button and reprogram the current time.
- Programmi mhux qed jiġu esegwiti: Ensure the timer is in 'AUTO' mode. Check that the ON/OFF times and days are correctly set.
7.1 Irrisettjar tat-Tajmer
To perform a full reset, press the 'Res' button (usually a small recessed button requiring a pointed object like a pen tip). This will clear all settings and return the timer to its factory default state. You will need to reprogram the current time and all desired ON/OFF cycles.
8. Għajnuniet għall-Utenti
- For precise control, utilize the full capacity of 96 ON/OFF programs to manage complex schedules.
- When setting intervals, remember the minimum programmable interval is 15 minutes.
- Always double-check your wiring before applying power to prevent damage to the unit or connected appliances.
9. Garanzija u Appoġġ