AVVENIMENT-DAWL-LOGO

EVENT LIGHTING APRO4-IP DMX Controller

EVENT-LIGHTING-APRO4-IP-DMX-Controller-PRODUCT-IMAGE

Għas-sigurtà tiegħek, jekk jogħġbok aqra dan il-manwal tal-utent bir-reqqa qabel l-użu.
Event Lighting jirriserva d-dritt li jirrevedi l-manwal fi kwalunkwe ħin. Informazzjoni u speċifikazzjonijiet f'dan il-manwal huma soġġetti għal tibdil mingħajr avviż. Event Lighting ma jassumi l-ebda responsabbiltà jew responsabbiltà għal xi żbalji jew ommissjonijiet. Jekk jogħġbok ikkonsulta Event Lighting għal kwalunkwe kjarifika jew informazzjoni dwar dan l-oġġett.

KARATTERISTIĊI

  • DMX 512, RDM, Artnet and sACN support
  • Konfigurazzjoni remota permezz ta 'intern webpaġna
  • Update firmware on Webpaġna
  • DMX output isolation
  • RJ45 Ethernet B input with POE(DC12V 2A)
  • Display LCD
  • Gigabit network, 100/1000mbps port speed
  • Klassifikazzjoni IP65

PANEL OVERVIEW

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (1)EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (2)

  1. Ethernet port RJ45
  2. Ethernet port RJ45
  3. Power in/out True1
  4. 2xDMX5pin connectors
  5. 2xDMX5pin connectors
  6. Holder tal-fjus
  7. LCD Display protection cover

MENUS
Below is controller Menus map

PrinċipaliMenu Submenu 1 Submenu 2 Valur/Għażla Default
Netwerk Modalità IP DHCP Statiku
Statiku
Indirizz IP 2.xx.xx.xx 2.xx.xx.xx
Maskra tas-Subnet 255.0.0.0 255.0.0.0
Port DMX Protokoll Artnet Artnet
sACN
Start Net 000‐127 000
Ibda l-Univers 000‐255 000
Port 1 Modalità Mitfi On
On
NET 000‐127 000
Univers 000‐255 000
Port 2 Modalità Mitfi On
On
NET 000‐127 000
Univers 000‐255 001
Port 3 Modalità Mitfi On
On
NET 000‐127 000
Univers 000‐255 002
Port 4 Modalità Mitfi On
On
NET 000‐128 000
Univers 000‐255 003
Itfi
Settings Rata DMX 20Hz 30Hz
25Hz
30Hz
35Hz
40Hz
RDM Itfi Itfi
Ippermettiet
Uri Fuq Dejjem 1Min
30Sec
1Min
5Min
Telf tas-Sinjal Żomm DMX Żomm DMX
Stop Output
Modalità Merge PH PH
LTP
Irrisettja l-Fabbrika Nru Nru
Iva

WEB konfigurazzjoni

NET device network IP mode can set to DHCP mode or Static mode.

Modalità DHCP

  • When APRO4‐IP is set to DHCP mode, you need to set the computer to DHCP also. And use a router for linking computer and APRO4‐IP device. The controller will show IP address like below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (3)
  • Enter IP address in your web browser, then you can login webpage to configure the parameter of controller. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (4)

Daħħal il-password: admin

Modalità statika

  • When APRO4‐IP device is set to Static mode, you need to set computer to be Static mode also. APRO4‐IP device will show IP address as below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (5)
  • Then set the IP address of computer is in the same IP range manually. For example: IP address must start with 2 according to APRO4‐IP address. And netmask is same with 255.0.0.0. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (6)
  • Input static IP address of APRO4‐IP device in your browser, then you can login to configure the parameter of device.

Daħħal il-password: admin EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (7)

  • When log on NET Config web, the first page show the information about APRO4‐IP. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • Following  is  for  Network  setting,  you  can  set  IP  mode  to  be  Static  or  DHCP,  IP  Address,and Subnet Mask. After setting, click Save button . EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • For DMX Port page , it is used for DMX Port setting. You can select Protocol to be Artnet or sACN, and set each port as input or output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (10)
  • On the page of Setting , you can set DMX Rate, RDM , Display On and Signal Loss. After setting, click Save to store the setting.
  • DMX  Rate:  You  can  set  20Hz,  25Hz,  30Hz,  35Hz,  40Hz,  30Hz  is default setting.
  • RDM: You can set RDM to be Disable or Enable.
  • There is 4 options for Display On mode: Always, 30Sec, 1Min, 5Min.
  • Telf tas-Sinjal: Can set as Hold DMX or Stop Output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (11)
  • You can return to factory setting by click Factory Reset button. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (12)
  • On Update page, you can update software of fixture by selecting the update software file of APRO4‐IP.
  • On the last page, you can reset password. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (13)

SPEĊIFIKAZZJONI

  • Qawwa fi: AC 100‐240V,50/60Hz
  • Konsum tal-enerġija: AC240V 50HZ 0.05A
  • Daqs: 215.3×150.5x42mm 4.2W
  • Piż: 1.43Kg
  • POE 802.3af
  • IP65

DIMENSJONIJIET

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (14)

Garanzija

Jekk jogħġbok irreferi għan-negozjant lokali tiegħek jew ikkuntattja Event Lighting. www.event‐lighting.com.au

Mistoqsijiet Frekwenti

How do I reset the APRO4-IP device to factory settings?

To perform a factory reset on the APRO4-IP device, access the Factory Reset option in the Main Menu under Settings. Confirm the reset to restore the device to its default configuration.

What is the default IP address for the APRO4-IP device?

The default IP address for the APRO4-IP device is set to DHCP mode. If you switch to Static mode, you can set a specific IP address within the range provided in the user manual.

Dokumenti / Riżorsi

EVENT LIGHTING APRO4-IP DMX Controller [pdfManwal tal-Utent
APRO4-IP, APRO4-IP DMX Controller, DMX Controller, Controller

Referenzi

Ħalli kumment

L-indirizz elettroniku tiegħek mhux se jiġi ppubblikat. L-oqsma meħtieġa huma mmarkati *