LINOVISION POE-SWR410UR

LINOVISION POE-SWR410UR 8-Port UltraReach PoE Switch User Manual

Model: POE-SWR410UR

1. Prodott Aktarview

The LINOVISION POE-SWR410UR is an 8-port UltraReach PoE Switch designed for reliable power and data transmission over extended distances. It features 8 10/100Mbps IEEE802.3af/at compliant PoE ports and 2 Gigabit Ethernet uplinks. This switch is equipped with two High PoE+ ports providing 45W output, suitable for power-intensive devices like PTZ cameras. Its remote cloud management capabilities allow for flexible network control.

This manual provides detailed instructions for the installation, operation, and maintenance of your LINOVISION POE-SWR410UR 8-Port UltraReach PoE Switch. Please read this manual thoroughly before use to ensure proper functionality and safety.

2. Kontenut tal-Pakkett

Upon opening the package, verify that all the following items are included and in good condition:

  • LINOVISION POE-SWR410UR 8-Port UltraReach PoE Switch
  • Adapter tal-Enerġija
  • User Manual (Quick Guide)
  • Parentesi u Viti tal-Immuntar
Image showing the LINOVISION POE-SWR410UR PoE Switch, power adapter, and user manual as included in the package.

Figura 2.1: Kontenut tal-Pakkett

Video 2.1: Unboxing the LINOVISION 8-Port UltraReach PoE Switch. This video demonstrates the contents of the product package.

3. Product Interface and Features

The POE-SWR410UR switch features a clear layout of ports and indicators for easy setup and monitoring.

Dijagramma li turi l-faċċata u d-dahar view of the LINOVISION POE-SWR410UR switch, highlighting 2 High PoE+ Ports, 8 UltraReach PoE Ports, 2 Gigabit Uplinks, Ground Terminal, and 130W Built-in Power Adapter.

Figure 3.1: Front and Back Panel Interface

Karatteristiċi ewlenin:

  • 8 UltraReach PoE Ports: These ports extend PoE and data transmission up to 2,600ft (800 meters). Note that bandwidth will be lowered to 10Mbps after 984ft (300 meters).
  • 2 High PoE+ Ports: The first two ports provide 45W High PoE+ output, suitable for powering large PTZ cameras or multi-imager cameras.
  • 2 Gigabit Uplink Ports: For high-speed connection to your network backbone.
  • Remote Cloud Management: Manage the switch via WEB GUI or RemoteMonit CLOUD, supporting VLAN, QoS, and PoE port management.
  • Built-in 130W Power Supply: Integrated power for convenience and reliability.

4. Setup u Installazzjoni

Follow these steps to set up your LINOVISION POE-SWR410UR switch:

  1. Iftaħ is-Swiċċ mill-pakkett: Neħħi s-swiċċ u l-aċċessorji kollha mill-imballaġġ bir-reqqa.
  2. Immuntar (Mhux obbligatorju): Use the provided mounting brackets and screws to secure the switch to a wall or rack if desired.
  3. Qabbad l-Enerġija: Connect the power adapter cable to the AC inlet on the back of the switch and then plug it into a standard AC power outlet. Ensure the ground terminal is properly connected for safety.
  4. Qabbad l-Apparati tan-Netwerk:
    • Connect your IP cameras, PTZ cameras, access points, or VoIP devices to the 8 UltraReach PoE ports (P1-P8).
    • For extended range beyond 984ft (300m) up to 2,600ft (800m), connect a POE-EXT3001LP (sold separately, ASIN: B0CTH7WNPK) at the remote end before the PoE device.
    • Connect your network router or main switch to the Gigabit Uplink ports (Uplink1, Uplink2) using standard Ethernet cables.
  5. Qawwa Mixgħul: Once all connections are secure, the switch will power on automatically. Observe the LED indicators for status.
Diagram illustrating the 2600ft UltraReach PoE transmission, showing a standard PoE switch setup versus the UltraReach PoE switch with a POE-EXT3001LP extender for longer distances.

Figure 4.1: UltraReach PoE Transmission Diagram

Nota Importanti:

  • The POE-EXT3001LP works only with standard PoE devices. Non-PoE devices cannot be used in UltraReach transmission.
  • The first two ports (P1, P2) are High PoE+ ports, providing up to 45W for high-power devices.
Graph comparing standard PoE output with the 45W High PoE+ output of the LINOVISION POE-SWR410UR switch, showing its capability for larger PTZ cameras.

Figure 4.2: High PoE+ Output Capability

5. Istruzzjonijiet Operattivi

The LINOVISION POE-SWR410UR is a managed switch, offering advanced configuration options through its webinterface tal-utent grafika bbażata fuq (WEB GUI) or the RemoteMonit CLOUD platform.

Remote Cloud Management:

Access the switch's management interface to configure various network settings and PoE functions:

  • PoE Port On/Off Control: Enable or disable PoE power for individual ports.
  • Ġestjoni tal-Baġit tal-Enerġija: Allocate and monitor the power budget for connected PoE devices.
  • Port Priority Settings: Assign priority levels to PoE ports to ensure critical devices receive power first during high demand.
  • Konfigurazzjoni tal-VLAN: Create Virtual Local Area Networks for network segmentation and improved security.
  • QoS (Kwalità tas-Servizz): Prioritize network traffic for specific applications or devices to ensure optimal performance.
  • Limitu tal-Veloċità tal-Port: Configure data transfer rates for individual ports.

Refer to the detailed online documentation or the quick guide for specific instructions on accessing and navigating the WEB GUI or RemoteMonit CLOUD interface.

Screenshot of the LINOVISION cloud management interface, showing device info, port status, and various settings like admin status, speed/duplex, and flow control.

Figure 5.1: Remote Cloud Management Interface

6. Manutenzjoni

Proper maintenance ensures the longevity and optimal performance of your PoE switch.

  • Tindif: Regularly clean the exterior of the switch with a soft, dry cloth. Avoid using liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris.
  • Ventilazzjoni: Ensure adequate airflow around the switch. Do not block the ventilation holes. Operate the switch within its specified temperature range.
  • Ġestjoni tal-Kejbil: Keep network cables organized and free from kinks or excessive tension to prevent damage and ensure reliable connections.
  • Aġġornamenti tal-Firmware: Periodically check the LINOVISION official website for firmware updates. Keeping the firmware updated can improve performance, add new features, and enhance security.
  • Provvista tal-Enerġija: Use only the provided power adapter. Ensure the power source is stable and within the specified voltagfirxa e.

7 Issolvi l-problemi

If you encounter issues with your POE-SWR410UR switch, refer to the following common troubleshooting steps:

  • Ebda Qawwa:
    • Check if the power adapter is securely connected to the switch and the power outlet.
    • Ivverifika li l-iżbokk tad-dawl huwa funzjonali.
    • Ensure the PWR LED indicator on the switch is lit.
  • Ebda Link/Attività fuq Port:
    • Kun żgur li l-kejbil Ethernet huwa konness sew kemm mal-port tas-swiċċ kif ukoll mat-tagħmir konness.
    • Ipprova kejbil Ethernet differenti biex teskludi ħsara fil-kejbil.
    • Check the Link/Act LED for the specific port. If it's off, there's no link.
    • Ivverifika li l-apparat konness ikun mixgħul u jaħdem sew.
  • No PoE Output:
    • Check the PoE LED indicator for the specific port.
    • Ensure the connected device is a PoE-compatible device (IEEE802.3af/at standard).
    • Verify that the total power budget of the switch (130W) is not exceeded.
    • If using UltraReach PoE, ensure the POE-EXT3001LP is correctly installed and the remote device is PoE-compatible.
    • Access the cloud management interface to ensure PoE is enabled for the port and check power budget settings.
  • Kwistjonijiet ta' Konnettività tan-Netwerk:
    • Check the uplink connections to your router or main network.
    • If using cloud management, verify network settings like VLAN and QoS configurations.
  • Resetting the Switch: If issues persist, you can perform a factory reset by pressing and holding the 'Reset' button on the front panel for approximately 5-10 seconds until the LEDs flash. This will restore default settings.

8. Speċifikazzjonijiet

KaratteristikaDeskrizzjoni
BrandLINOVIŻJONI
Numru tal-MudellPOE-SWR410UR
Numru ta' Portijiet8 (PoE) + 2 (Gigabit Uplink)
Standard PoEIEEE802.3af/at compliant
High PoE+ Ports2 ports, 45W output each
UltraReach PoE RangeUp to 2600ft (800m) with POE-EXT3001LP (bandwidth 10Mbps after 984ft/300m)
Rata ta' Trasferiment tad-Data10/100Mbps (PoE ports), 1000Mbps (Gigabit Uplink ports)
Tip ta' SwiċċImmexxi
Provvista tal-Enerġija130W inkorporat
Voltage100-240V AC, 50/60Hz
Piż tal-oġġett1.2 Kilogramma (2.64 lbs)
Dimensjonijiet (L x W x H)8.66" (220mm) x 5.90" (150mm) x 1.77" (45mm)
KulurIswed

9. Garanzija

The LINOVISION POE-SWR410UR PoE Switch comes with a 3-year warranty. This warranty covers defects in materials and workmanship under normal use. For warranty claims or detailed terms and conditions, please contact LINOVISION customer support or refer to the official product documentation.

10. Appoġġ

For further assistance, technical support, or product inquiries, please utilize the following resources:

  • LINOVISION Official Websit: Visit the official LINOVISION websit għal FAQs, manwali aġġornati, u informazzjoni ta' kuntatt għall-appoġġ.
  • Servizz tal-Klijent: Contact LINOVISION customer service directly for personalized support.
  • Ħanut online: Tista 'wkoll iżżur il- LINOVISION Store on Amazon għal informazzjoni dwar il-prodott u aċċessorji relatati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.