1. Prodott Aktarview
The ALIENTEK DM40 series is a professional 4.5-digit digital multimeter (59999 count Max) designed for fast and accurate measurements. It integrates the functions of a multimeter, oscilloscope, and signal generator into a single handheld device. Equipped with a high-precision 5ppm reference source, it ensures long-term stability and reliability for various applications, from automotive diagnostics to industrial and scientific use.
Karatteristiċi Ewlenin
- Professional 4.5-Digit Multimeter: Offers 59999 counts maximum, ensuring high precision and accuracy.
- Integrated 3-in-1 Functionality: Combines a digital multimeter, oscilloscope, and signal generator.
- Kejl Awtomatiku: Features auto mV/V and μA/mA/A gear measurement, eliminating the need for manual range switching.
- AC+DC Mixed Measurement: DM40B/C models can display both AC and DC components simultaneously for complex signal analysis.
- Ultra-Fast Continuity & Diode Test: Provides quick continuity checks and innovative diode function with multiple voltage drop measurements and distinct audible indicators.
- High-Resolution IPS Touchscreen: A 3.5-inch (480*320) screen offers fine display and convenient interactive control.
- Oscilloscope Specifications: 10-bit ADC, 50MHz sampling rate, and 10MHz bandwidth.
- Ġeneratur tas-Sinjal: Built-in function for generating various waveforms.
- Ġestjoni tad-Data: Supports auto-measurement, relative measurement, data logging, data hold, and trend graph display.

Figure 1: The ALIENTEK DM40 series combines multimeter, oscilloscope, and signal generator functions.

Figura 2: Aktarview of the DM40's high-quality features, including various measurement modes and display options.
2. X'hemm fil-Kaxxa
Jekk jogħġbok iċċekkja l-kontenut tal-pakkett tiegħek malli tirċevih biex tiżgura li l-oġġetti kollha huma preżenti:
- ALIENTEK DM40A/B/C Digital Multimeter
- MP01 Test Leads (Red and Black)
- Probe Leads
- USB-C Cable
- Batterija waħda ta' 1V (inkluża)
3. Setup
3.1 Installazzjoni u Iċċarġjar tal-Batterija
The DM40 series multimeter is equipped with an internal rechargeable battery. Ensure the battery is properly installed and charged before initial use. Connect the device using the provided USB-C cable to a suitable power source (e.g., USB wall adapter, computer USB port) for charging. A full charge provides over 10 hours of continuous operation for multimeter functions and 10 hours for oscilloscope functions.
3.2 Konnessjoni tal-wajers tat-test
Proper connection of test leads is crucial for accurate and safe measurements. Refer to the following guidelines:
- Għal ħafna kejl (Voltage, Resistance, Capacitance, Diode, Continuity, Frequency, Temperature), insert the black test lead into the COM (Common) port and the red test lead into the VΩHz port.
- For current measurements (μA, mA, A), insert the black test lead into the COM port and the red test lead into the A mA μA port. Ensure the correct port is used to avoid damage to the device or circuit.

Figure 3: Proper connection of test leads for voltage, reżistenza, u kejl ieħor.
4. Istruzzjonijiet Operattivi
4.1 Power On/Off
To power on the device, press and hold the power button located on the side or front panel until the screen illuminates. To power off, press and hold the same button until the screen shuts down.
4.2 Automatic Measurement Mode
The DM40 series excels in its automatic measurement capabilities. In AUTO mode, the multimeter intelligently detects the type of measurement (DC/AC voltage, current, resistance, etc.) and automatically switches to the appropriate range. This feature significantly simplifies operation, especially for users who need to quickly assess various parameters without manual configuration.

Figure 4: Automatic voltage measurement in progress, showing auto-ranging capabilities.
4.3 Titjiratage Measurement (DC, AC, AC+DC)
Biex tkejjel il-voltage, ensure test leads are connected to the VΩHz and COM ports. The multimeter automatically detects DC or AC voltage. For AC+DC mixed measurements (available on DM40B/C models), the device displays both AC and DC components simultaneously, providing a comprehensive view of complex signals. The small text on the top left and right of the display shows the AC and DC voltage values respectively.
Safety Warning: When the measured voltage exceeds 30V, the display font will turn red, and a red lightning symbol will appear, indicating potentially hazardous voltage levels. Always exercise extreme caution when working with high voltages.

Figure 5: AC+DC mixed measurement and trend chart display on the DM40 multimeter.
4.4 Current Measurement (DC, AC, AC+DC)
For current measurements, insert the red test lead into the A mA μA port and the black lead into the COM port. Use the current range button to cycle through DC, AC, or AC+DC measurement modes. The device supports automatic range switching for current, from microamperes (μA) to amperes (A).
4.5 Test tad-Diode
The innovative diode test function allows for precise voltage drop measurement across diodes. The device provides distinct audible indicators for different voltage drop ranges, making it easy to identify diode characteristics. This test is performed with high accuracy.

Figure 6: Diode test function displaying voltage drop measurements.
4.6 Test ta' Kontinwità
The ultra-fast continuity test allows you to quickly check for open or closed circuits. An audible beep indicates a continuous path, while no sound suggests an open circuit. This function is highly responsive, with quick measurements typically less than 1 microsecond.
4.7 Funzjoni tal-Oxxilloskopju
The integrated oscilloscope function provides advanced waveform analysis capabilities. With a 10-bit ADC, 50MHz sampling rate, and 10MHz bandwidth, it allows for detailed observation of electrical signals. Key features include various time scales, vertical scales, coupling options (AC/DC), and mathematical functions like FFT/ABS.
4.8 Ġeneratur tas-Sinjal
The built-in signal generator can produce various waveforms, including sine, sawtooth, triangular, and square waves. This is useful for testing circuits, calibrating other equipment, or generating specific signals for experimental setups. Frequencies range from 1Hz to 10MHz depending on the waveform type.
4.9 IPS Touchscreen Interaction
The 3.5-inch IPS touchscreen provides an intuitive interface for navigating menus, selecting functions, and viewing measurement data. Its high resolution (480*320) ensures a clear and detailed display, enhancing user experience.

Figure 7: The high-resolution 3.5-inch IPS touchscreen for clear display and interaction.
4.10 Data Logging and Trend Graph
The DM40 supports essential data management features such as data logging, data hold, and relative measurement. The trend graph function allows users to visualize measurement data periodically, with adjustable time bases (160ms/320ms/640ms), aiding in the observation of signal changes and stability over time.
4.11 Vidjo Uffiċjali tal-Prodott
Video 1: This video demonstrates the voltage and current measurement capabilities of the ALIENTEK DM40 Digital Oscilloscope Multimeter, including auto-ranging, AC/DC measurements, and safety warnings for high voltage.
5. Manutenzjoni
5.1 Tindif
To maintain the device's performance and appearance, wipe the exterior with a soft, damp drapp. Tużax prodotti tat-tindif li joborxu, solventi, jew kimiċi ħarxa, għax dawn jistgħu jagħmlu ħsara lis-casing jew skrin. Kun żgur li l-apparat ikun mitfi u skonnettjat minn kwalunkwe sors ta' enerġija qabel ma tnaddaf.
5.2 Kura tal-Batterija
The DM40 series features a high-capacity rechargeable battery designed for over 10 hours of use. For optimal battery life and performance:
- Evita li tiċċarġja l-batterija kompletament ta' spiss.
- Iċċarġja l-apparat regolarment, anke jekk ma jkunx qed jintuża kontinwament.
- Aħżen l-apparat f'post frisk u niexef meta ma jkunx qed jintuża għal perjodi twal.
- The multimeter communication is fully isolated, ensuring safety during operation and charging.
5.3 Ħażna
Store the multimeter in a dry, dust-free environment away from direct sunlight, extreme temperatures, and high humidity. Keep it away from strong magnetic fields and corrosive gases. If storing for a long period, ensure the battery has a partial charge (around 50%) to prolong its lifespan.
6 Issolvi l-problemi
This section addresses common issues you might encounter with your ALIENTEK DM40 multimeter.
6.1 "OL" Display (Overload)
If the display shows "OL" (Overload), it indicates that the measured value exceeds the current range or maximum input limit of the selected function. To resolve this:
- If in manual range mode, switch to a higher measurement range.
- Ensure the input is within the device's specified maximum limits for the selected function.
- For current measurements, verify that the test lead is inserted into the correct current measurement port (A mA μA) and not the voltagport elettroniku.
6.2 No Reading or Inaccurate Readings
- Check Test Lead Connections: Ensure the test leads are securely inserted into the correct ports on the multimeter and are making good contact with the circuit being measured.
- Livell tal-batterija: Verify that the battery is sufficiently charged. A low battery can affect measurement accuracy.
- Correct Mode Selection: Confirm that the appropriate measurement mode (e.g., DC Voltage, AC Current, Resistance) is selected for the task.
- Damaged Leads: Inspect the test leads for any signs of damage (e.g., frayed wires, broken insulation). Replace damaged leads immediately.
6.3 L-Apparat Mhux Qed Jixgħel
- Iċċarġja Batterija: Connect the multimeter to a power source using the USB-C cable and allow it to charge for some time.
- Buttuna tal-Qawwa: Kun żgur li l-buttuna tal-qawwa hija ppressata u miżmuma sew.
7. Speċifikazzjonijiet
Detailed technical specifications for the ALIENTEK DM40A/B/C Digital Multimeter are provided below.
7.1 Informazzjoni Bażika
| Parametru | Valur |
|---|---|
| Mudell | DM40A/B/C |
| Skrin | Full Touch 3.5" IPS (480*320) |
| Ħajja tal-batterija | 12H (Multimeter) / 10H (Oscilloscope) |
| Dimensjonijiet | 5.5 x 3 x 1 pulzieri (140 x 83 x 25 mm) |
| Piż tal-oġġett | 1.89 libbra (260g) |
| Interface | USB-C, MCX, Banana Seat |
| Sors tal-Enerġija | Imħaddem bil-batterija (batterija 1 x 9V inkluża) |
| Speċifikazzjoni Met | CE, FCC |
7.2 Oscilloscope / Signal Generator Technical Parameters
| Parametru | Valur |
|---|---|
| Sample Rata | 50MSa / s |
| Bandwidth | 10MHz |
| Profond tal-Memorja | 64Kpts |
| Skala ta' Ħin | 100ns ~ 50s |
| Skala Vertikali | 10mV ~ 10V/div (X1) |
| Riżoluzzjoni | 10Bit |
| Akkoppjar | AC/DC |
| Impedenza tad-dħul | 1MΩ |
| Modalità tal-Bażi tal-Ħin | Awto/Normali/Single |
| Modalità Knis | Tlugħ/Tnaqqis |
| Funzjonijiet tal-Matematika | FFT/ABS |
| Tipi ta 'forma ta' mewġ | Sinus, Kwadru, Trijangolari, Sawtooth |
7.3 Measurement Ranges and Accuracy
| Funzjoni | DM40A Range | DM40B Range | DM40C Range | Eżattezza |
|---|---|---|---|---|
| DC Voltage | 400mV/4V/40V/400V/1000V | 500mV/5V/50V/500V/1000V | 600mV/6V/60V/600V/1000V | ± (0.03% + 5d) |
| AC Voltage | 400mV/4V/40V/400V/750V | 500mV/5V/50V/500V/750V | 600mV/6V/60V/600V/750V | ± (0.3% + 15d) |
| Kurrent DC | 400μA/4000μA/40mA/400mA, 4A/10A | 500μA/5000μA/50mA/500mA, 5A/10A | 600μA/6000μA/60mA/600mA, 6A/10A | ±(0.15%+5d) (μA/mA), ±(0.2%+5d) (A) |
| Kurrent AC | 400μA/4000μA/40mA/400mA, 4A/10A | 500μA/5000μA/50mA/500mA, 5A/10A | 600μA/6000μA/60mA/600mA, 6A/10A | ±(0.5%+15d) (μA/mA), ±(0.75%+15d) (A) |
| Reżistenza | 400Ω/4KΩ/40KΩ/400KΩ/4MΩ/40MΩ | 500Ω/5KΩ/50KΩ/500KΩ/5MΩ/50MΩ | 600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ | ±(0.1%+5d) (Ω), ±(0.2%+10d) (MΩ) |
| Kapaċità | 4nF/40nF/400nF/4μF/40μF/400μF/4mF | 5nF/50nF/500nF/5μF/50μF/500μF/5mF | 6nF/60nF/600nF/6μF/60μF/600μF/6mF | ±(2.5%+30d) (nF-μF), ±(3.5%+30d) (mF) |
| Frekwenza | 10Hz ~ 40MHz | 10Hz ~ 50MHz | 10Hz ~ 60MHz | ± (0.01% + 5d) |
| Temperatura | -40°C ~ 1000°C (-40°F ~ 1832°F) | -40°C ~ 1000°C (-40°F ~ 1832°F) | -40°C ~ 1000°C (-40°F ~ 1832°F) | ±(1.0%+5°C) (probe range -20°C~300°C), ±(1.5%+5°F) |
| Kontinwità | 0Ω ~ 1KΩ | 0Ω ~ 1KΩ | 0Ω ~ 1KΩ | ± (0.2% + 5d) |
| Dajowd | 0V ~ 3.0V, 0Ω ~ 1KΩ | 0V ~ 3.0V, 0Ω ~ 1KΩ | 0V ~ 3.0V, 0Ω ~ 1KΩ | ± (1% + 5d) |
7.4 Special Features Comparison
| Karatteristika | DM40A | DM40B | DM40C |
|---|---|---|---|
| Maximum Display (Counts) | 39999 | 49999 | 59999 |
| Modalità AUTO | ✓ | ✓ | ✓ |
| TRMS | ✓ | ✓ | ✓ |
| Rispons ta' Frekwenza | 10KHz | 10KHz | 10KHz |
| Kejl AC + DC | ✓ | ✓ | |
| Duty Cycle Measure | 5%~95% | 5%~95% | 5%~95% |
| Żamma tad-Data (HOLD) | ✓ | ✓ | ✓ |
| Relative Measurement (RLE) | ✓ | ✓ | ✓ |
| Extreme Value Measurement (Max/Min) | ✓ | ✓ | ✓ |
| Trend Chart (WAVE) | ✓ | ✓ | ✓ |
7.5 Signal Generator Waveform Parameters
| Parametru | Mewġa Sinj | Sawtooth Wave | Triangular Wave | Mewġa Pjazza |
|---|---|---|---|---|
| Proġett | DM40A/B/C | |||
| Frekwenza | 1Hz ~ 50KHz | 100KHz ~ 10MHz | ||
| Ampil-lititudni | 0.5V ~ 3.0Vpp | 3.0Vpp | ||
| Iċ-Ċiklu tax-Xogħol | Mhux aġġustabbli | 0 ~ 100% | ||
8. Informazzjoni dwar is-Sigurtà
Always adhere to the following safety precautions to prevent personal injury or damage to the multimeter or equipment under test.
- Klassifikazzjonijiet tas-Sigurtà: The DM40 series is rated for CAT IV 600V and CAT III 1000V. Always ensure your measurements are within these categories and voltage limiti.
- Maximum Limits: Tippruvax tkejjel il-voltages or currents that exceed the specified maximums for each range. Refer to the specifications table.
- Isolated Communication: The multimeter features fully isolated communication, enhancing safety during operation.
- Spezzjona l-wajers tat-test: Always inspect test leads for any signs of damage (e.g., cracks, frayed insulation) before each use. Replace damaged leads immediately.
- Vol Għolitage Twissija: Meta tkejjel il-voltages above 30V, the device will display a red warning on the screen. Exercise extreme caution and use appropriate personal protective equipment.
- Proper Port Usage: Always connect test leads to the correct input jacks for the desired measurement. Incorrect connections can lead to damage or injury.
9. Garanzija u Appoġġ
9.1 Pjanijiet ta' Protezzjoni
Optional protection plans are available to extend the coverage of your ALIENTEK DM40 Digital Multimeter:
- Pjan ta' Protezzjoni ta' 3 Snin: Provides extended coverage for three years.
- Pjan ta' Protezzjoni ta' 4 Snin: Provides extended coverage for four years.
- Protezzjoni Kompleta: A comprehensive plan that covers all eligible past and future purchases (available with monthly billing).
Jekk jogħġbok irreferi għat-termini u l-kundizzjonijiet speċifiċi ta' kull pjan ta' protezzjoni għal aktar dettalji.
9.2 Appoġġ għall-Klijent
For technical assistance, warranty claims, or any further inquiries regarding your ALIENTEK DM40 Digital Multimeter, please contact ALIENTEK customer support through your purchase platform or visit the official ALIENTEK website for contact information. Our support team is available to help you with any questions or issues you may have.