1. Introduzzjoni
This manual provides detailed instructions for the setup, operation, and maintenance of your Generic HY-500B 5MP USB Microscope Camera. This digital industrial camera, equipped with a 150X C-Mount Lens, is designed for observation and analysis, offering high-definition imaging capabilities.
2. Kontenut tal-Pakkett
Jekk jogħġbok ivverifika li l-oġġetti kollha elenkati hawn taħt huma inklużi fil-pakkett tiegħek:
- 1 x 5.0MP Microscope Camera
- 1 x USB Line
- 1 x Software Disc
- 1 x 150X C-Mount Lens
- 1 x Foldable Stand
- 1 x Dawl LED

Image: The complete HY-500B kit, showing the camera, 150X C-mount lens, foldable stand, and LED light.
3. Speċifikazzjonijiet
- Riżoluzzjoni tal-kamera: 5.0 Megapixels
- Tip ta' Lenti: C-Mount Zoom Lens
- Zoom Ratios: 5:1
- Qawwa ta' Tkabbir: 0.11X - 2X (with 150X C-Mount Lens)
- Rispons Spettrali: 400nm~1000nm
- Medda Dinamika: 74 dB (Linear), 85 dB (HDR)
- Sensittività: 2400 mV/Lux-sec
- Tul tal-Cable USB: 1.5 Meter
- Dimensjonijiet tal-kamera: 100mm (Length) * 28mm (Diameter)
- Piż tal-oġġett: Madwar 1.76 liri (800 gramma)
- Numru tal-Mudell: EKBCAXNHN-FULLKIT

Immaġni: Dettaljata view of the 5MP camera sensor, highlighting its internal components.
4. Gwida ta' Setup
- Arma l-Istand: Secure the foldable stand to a stable surface using its clampAġġusta d-driegħ għall-pożizzjoni mixtieqa tiegħek.
- Attach the Camera and Lens: Screw the 150X C-Mount Lens onto the 5.0MP Microscope Camera. Then, mount the assembled camera and lens unit onto the foldable stand's holder.
- Connect the LED Light: Attach the LED light to the stand and position it to illuminate your observation area. Connect its power source if separate.
- Qabbad mal-Kompjuter: Plug the USB line from the microscope camera into an available USB port on your computer.
- Installa Software: Insert the provided Software Disc into your computer's optical drive. Follow the on-screen instructions to install the necessary drivers and observation software. If your computer lacks an optical drive, please contact support for alternative software download options.

Image: The HY-500B camera and lens mounted on the foldable stand, with the LED light positioned for illumination.
5. Istruzzjonijiet Operattivi
- Tnedija tas-Softwer: Open the installed microscope observation software on your computer. The camera feed should appear automatically.
- Place Specimen: Position the object you wish to observe directly under the microscope lens.
- Aġġusta Focus: Use the focus ring on the 150X C-Mount Lens to achieve a clear image.
- Aġġusta l-Ingrandiment: The C-Mount lens offers a zoom ratio of 5:1, providing magnification from 0.11X to 2X. Rotate the zoom ring on the lens to change the magnification level.
- Control Illumination: Turn on the LED light and adjust its position and brightness to ensure optimal lighting for your specimen.
- Aqbad Stampi/Vidjows: Utilize the software interface to capture still images or record video footage of your observations. Refer to the software's help documentation for specific controls.

Image: The 5MP USB microscope camera, ready for lens attachment and operation.
6. Manutenzjoni
- Tindif tal-Lenti: Use a soft, lint-free cloth specifically designed for optical lenses to gently wipe the lens surface. For stubborn smudges, a small amount of lens cleaning solution can be applied to the cloth, not directly to the lens.
- Tindif tal-Korp tal-Kamera: Wipe the camera body and stand with a dry, soft cloth. Avoid using harsh chemicals or abrasive materials.
- Ħażna: When not in use, store the microscope camera and its components in a clean, dry, and dust-free environment. Use protective caps for the lens and camera sensor if available.
- Kura tal-Cable: Evita li tgħawweġ jew tgħawweġ il-kejbil USB b'mod eċċessiv biex tevita ħsara interna.
7 Issolvi l-problemi
- No Image Displayed in Software:
- Kun żgur li l-kejbil USB huwa konness sew kemm mal-kamera kif ukoll mal-kompjuter.
- Verify that the camera drivers are correctly installed. Reinstall from the software disc if necessary.
- Ipprova qabbad ma 'port USB differenti fuq il-kompjuter tiegħek.
- Restart the observation software or your computer.
- L-immaġni hija mċajpra:
- Adjust the focus ring on the 150X C-Mount Lens until the image is sharp.
- Ensure the specimen is properly positioned and stable.
- Check if the lens or camera sensor is dirty and clean as per maintenance instructions.
- Dawl LED ma Jaħdimx:
- Check the power connection for the LED light.
- Ensure the light is switched on (if it has a separate switch).
8. Garanzija u Appoġġ
This product is manufactured with high-quality materials to ensure durability and stability. We are committed to providing excellent after-sales service.
If you encounter any questions, require assistance, or need to report an issue, please do not hesitate to contact our customer support team. We are available to serve you wholeheartedly.
Jekk jogħġbok irreferi għad-dokumentazzjoni tax-xiri tiegħek għal termini speċifiċi tal-garanzija u informazzjoni ta' kuntatt.