The Tzone HTD701 is a digital temperature and humidity data logger designed for precise environmental monitoring. It simultaneously measures and records ambient temperature, dew point, wet bulb temperature, and relative humidity. Featuring a USB interface for automatic report generation and an intuitive display, it is suitable for various applications including laboratories, HVAC systems, greenhouses, and freezers.

2. Kontenut tal-Pakkett

Tzone HTD701 Package Contents: Data Logger, Temperature/Humidity Probe, USB Cable, User Manual, Calibration Certificate, Portable Box

Ivverifika li l-oġġetti kollha huma preżenti fil-pakkett:

  • 1 x Tzone HTD701 Temperature and Humidity Data Logger
  • 1 x Temperature and Humidity Probe
  • 1 x USB Type-C Cable
  • 1 x Manwal għall-Utent
  • 1 x Ċertifikat ta 'kalibrazzjoni
  • 1 x Kaxxa tal-Ħażna Portabbli

This image displays the complete contents of the Tzone HTD701 package, including the main data logger unit, the external temperature and humidity probe, a USB-C cable for data transfer, the user manual, a calibration certificate, and a protective portable box.

3. Prodott Aktarview

Tzone HTD701 Data Logger with labeled parts: LCD Screen Display, ON/OFF/Backlight Key, Back Key, Multi-function Key, Data Hold, Max/Min/Avg Value, Temp Unit Switch, Battery Box, Temp & RH Probe, USB Port.

The HTD701 features an intuitive design with clearly labeled components for ease of use:

  • Display LCD Screen: Shows current readings, settings, and data trends.
  • ON/OFF/Backlight Key: Powers the device on/off and controls screen backlight.
  • Ċavetta lura: Jinnaviga lura fil-menus.
  • Ċavetta b'ħafna funzjonijiet: Used for various menu selections and confirmations.
  • Żamma tad-Data: Freezes the current display readings.
  • Max/Min/Avg Value: Displays maximum, minimum, and average recorded values.
  • Temp Unit Switch: Toggles between °C, °F, and K temperature units.
  • Kaxxa tal-Batterija: Houses the 3 AA batteries.
  • Temp & RH Probe: External sensor for temperature and relative humidity measurements.
  • Port USB: For data transfer and power supply.

Din l-immaġni tipprovdi deskrizzjoni dettaljata view of the Tzone HTD701 data logger, highlighting its various buttons, the LCD screen, the external temperature and humidity probe, and other key features. Dimensions are also indicated.

4. Karatteristiċi

  • Simultaneous Measurement: Records ambient temperature (-40°C to 125°C), dew point (-40°C to 80°C), wet bulb temperature (-40°C to 80°C), and relative humidity (0 to 100% RH).
  • Ġenerazzjoni Awtomatika ta' Rapporti: Connect via USB to automatically generate TXT/CSV/XLS/PDF data reports without requiring special software.
  • Large Data Capacity: Stores up to 49,920 groups of data.
  • Parametri Aġġustabbli: Easily set temperature and humidity alarm ranges, auto-off mode, backlight time, and logging intervals.
  • Allarmi tal-Ħsejjes: Audible alerts when temperature or humidity exceeds set limits.
  • Display tad-dawl ta' wara: Ensures clear readability in low-light conditions.
  • Disinn umanizzat: Anti-slip and anti-collision casing, foldable stand, and hanging design for versatile placement.
  • Qlib ta' Unità tat-Temperatura: Supports °C, °F, and K units.
Multi-functional features of Tzone HTD701: Data Hold, Auto-Off, Low Power Consumption, LCD, Backlight.

This image illustrates the multi-functional aspects of the data logger, including data hold, auto-off, low power consumption, LCD display, and backlight.

Humanized design features of Tzone HTD701: Battery replaceable, Power Supply via USB Cable, Flexible Angle Adjustment with stand, Hanging Design.

This image highlights the user-friendly design elements such as replaceable batteries, USB power option, a flexible stand, and a hanging feature.

5. Setup u Installazzjoni

  1. Installazzjoni tal-batterija: Open the battery compartment on the back of the device and insert 3 AA batteries, ensuring correct polarity.
  2. Konnessjoni tas-Sonda: Connect the temperature and humidity probe to the designated port on the top of the data logger. Ensure a secure connection.
  3. Qawwa Mixgħul: Press the ON/OFF button to power on the device. The LCD screen will illuminate.
  4. Pjazzament Inizjali: Place the data logger in the desired monitoring location. Utilize the foldable stand for desktop use or the hanging design for elevated placement.
  5. Poġġiment tas-Sonda: Carefully place the temperature and humidity probe within the area where measurements are to be taken. Ensure the probe is not obstructed and has adequate air circulation.

This video demonstrates the unboxing and initial setup of the Tzone HTD701 data logger, showing how to connect the probe and power on the device.

This video provides a visual guide on connecting the external probe and placing it in a measurement environment, such as a freezer, for data recording.

6. Operazzjoni

  1. Viewing Current Data: Upon powering on, the LCD will display current temperature, humidity, and a graph of recent data.
  2. Qlib tal-Modi tal-Wiri: Use the navigation buttons to cycle through different display modes, including dew point and wet bulb temperature readings.
  3. Żamma tad-Data: Press the 'HOLD' button to freeze the current readings on the screen. Press again to release.
  4. Massimu/Minimu/Medja: Press the 'MAX/MIN/AVG' button to view the maximum, minimum, and average recorded values.
  5. Swiċċ tal-Unità tat-Temperatura: Press the '°C/°F/K' button to change the temperature unit between Celsius, Fahrenheit, and Kelvin.
Tzone HTD701 Data Logger displaying current temperature and humidity data with a trend graph on its LCD screen.

This image shows the Tzone HTD701 data logger actively monitoring and displaying temperature and humidity data, along with a graphical representation of the trends.

7. Reġistrazzjoni u Rappurtar tad-Data

  1. Setting Logging Parameters: Navigate to the 'Logging' menu to set the logging interval, start time, and file format (TXT, CSV, XLS, PDF).
  2. Starting Logging: Select 'Start Logging' from the menu to begin recording data. The device will log data at the set interval.
  3. Stopping Logging: To stop logging, navigate back to the 'Logging' menu and select 'Stop Logging'. Confirm your choice.
  4. Trasferiment tad-Data: Connect the data logger to a computer using the provided USB Type-C cable. The device will automatically generate data reports in the selected format.
  5. Accessing Reports: The generated reports can be found as removable storage on your computer. No special software is required for report generation.
Tzone HTD701 Data Logger connected via USB to a laptop, displaying automatically generated data reports in TXT, CSV, XLS, and PDF formats.

This image demonstrates the Tzone HTD701 data logger connected to a laptop, showcasing its ability to automatically generate data reports in various formats (TXT, CSV, XLS, PDF) without the need for additional software.

8. Alarms and Settings

  1. Aċċess għas-Settings: Navigate to the 'Menu' on the device and select 'Settings' to adjust various parameters.
  2. Issettjar tal-Limiti tal-Allarm: In the 'Alert' menu, set the upper and lower limits for temperature and humidity. If readings exceed these limits, an audible alarm will sound.
  3. Auto-Off Mode: Configure the auto-off duration to conserve battery life.
  4. Ħin tad-dawl ta' wara: Adjust the duration for which the screen backlight remains active.
  5. Kalibrazzjoni: The device comes with a calibration certificate. Refer to the 'Calibration' menu for any advanced calibration needs, if applicable.
Tzone HTD701 Data Logger displaying its menu for setting parameters like sound, logging, auto-off, alert, and calibration, with a sound alarm icon.

This image shows the Tzone HTD701 data logger's menu interface, illustrating how users can access and adjust various parameters such as sound settings, logging options, auto-off, alert thresholds, and calibration. A sound alarm icon is also visible.

9. Speċifikazzjonijiet

ParametruValur
Temperature Measurement Range (Environmental)-40°C sa 125°C
Temperature Measurement Range (Dew Point)-40°C sa 80°C
Temperature Measurement Range (Wet Bulb)-40°C sa 80°C
Relative Humidity Measurement Range0 sa 100% RH
Unitajiet tat-Temperatura°C / °F / K
Kapaċità tal-Ħażna tad-Dejta49,920 gruppi
Riżoluzzjoni0.1
Rata ta' Kejl1 darba/sekonda
Sors tal-Enerġija3 x 1.5V AA Batteries (included)
KonnettivitàUSB Tip-Ċ
Piż tal-oġġett2.35 liri
Dimensjonijiet tal-Pakkett10.83 x 8.82 x 3.11 pulzieri
Tzone HTD701 Data Logger displaying its specifications on screen, including temperature and humidity measurement ranges, data storage, resolution, and measurement rate.

This image visually summarizes the key technical specifications of the Tzone HTD701 data logger.

10. Manutenzjoni

  • Tindif: Wipe the device and probe with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sostituzzjoni tal-batterija: Replace batteries when the low battery indicator appears on the screen to ensure continuous operation and data integrity.
  • Ħażna: When not in use for extended periods, remove the batteries and store the device in its portable box in a cool, dry place away from direct sunlight and extreme temperatures.
  • Kura tas-Sonda: Handle the external probe with care. Avoid bending or damaging the cable and sensor tip.

11 Issolvi l-problemi

  • L-Apparat Mhux Jixgħel:
    • Iċċekkja jekk il-batteriji humiex installati sew u għandhomx biżżejjed ċarġ. Ibdelhom jekk meħtieġ.
  • Qari mhux eżatt:
    • Ensure the probe is clean and free from dust or debris.
    • Verify the probe is securely connected to the main unit.
    • Allow the device to stabilize in the measurement environment for a few minutes.
  • Data Not Logging:
    • Check logging settings to ensure a logging interval is set and logging has been initiated.
    • Verify that the device has sufficient memory capacity.
  • Kwistjonijiet ta' Konnessjoni USB:
    • Ensure the USB cable is properly connected to both the device and the computer.
    • Ipprova port USB differenti fuq il-kompjuter tiegħek.
  • Allarm ma Ddoqq:
    • Check the 'Alert' settings to ensure alarm limits are correctly configured and the alarm mode is enabled.
    • Verify the device's volume settings.

12. Garanzija u Appoġġ

Tzone products are covered by a standard manufacturer's warranty. For specific warranty details, technical support, or service inquiries, please refer to the contact information provided in the product packaging or visit the official Tzone websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal talbiet ta' garanzija.