1. Introduzzjoni

This manual provides detailed instructions for the safe and effective operation of the WOOXGEHM T6125 Digital Insulation Resistance Tester. The T6125 is a robust, shockproof, and dustproof instrument designed for measuring insulation resistance, absorption ratio (DAR), polarization index (PI), AC voltage, and low resistance. It features a wide measurement range, multiple output voltage levels, a large LCD with backlight, and strong anti-interference capabilities, making it suitable for various electrical equipment testing applications.

WOOXGEHM T6125 Digital Insulation Resistance Tester front view

Figure 1: WOOXGEHM T6125 Digital Insulation Resistance Tester.

2. Informazzjoni dwar is-Sigurtà

To ensure safe operation and prevent damage to the instrument or injury to personnel, please read and understand all safety instructions before use.

  • Always observe local and national safety codes.
  • Do not operate the tester if it appears damaged or is not functioning properly.
  • Ensure the circuit under test is de-energized and discharged before connecting test leads for resistance measurements.
  • Use only the provided test leads and accessories.
  • Avoid touching the test leads or the circuit under test during measurement, especially when high voltages huma preżenti.
  • Do not use the instrument in wet environments or explosive atmospheres.
  • Ibdel il-batteriji minnufih meta jidher l-indikatur ta’ batterija baxxa.

3. Kontenut tal-Pakkett

Iċċekkja li l-oġġetti kollha elenkati hawn taħt huma preżenti fil-pakkett tiegħek:

  • 1 x WOOXGEHM T6125 Digital Insulation Resistance Tester
  • 1 x Par Ċomb tat-Test
  • 1 x External Power Plug (5.5mm)
  • 2 x Alligator Clips
  • 1 x Borża tad-Drapp
  • 1 x Manwal tal-Utent (bl-Ingliż)

4. Prodott Aktarview

The T6125 insulation tester is designed for comprehensive electrical insulation testing. Key features include:

  • Kejl tar-Reżistenza għall-Insulazzjoni: Measures insulation opposition, absorption ratio, and polarization index.
  • AC Voltage Kejl: Capable of measuring AC voltage.
  • Low Resistance Measurement: For continuity checks.
  • Multiple Test Voltages: Offers 100V, 250V, 500V, 1000V, and 2500V test voltage għażliet.
  • Automatic Discharge Function: Ensures safety after high voltage testijiet.
  • Żamma tad-Data: Freezes the displayed measurement for easy recording.
  • Over-range Alarm: Alerts the user when measurements exceed the selected range.
  • Tfigħ Awtomatiku: Jintefa wara 30 minuti ta' inattività biex jikkonserva l-ħajja tal-batterija.
  • LCD kbir b'dawl minn wara: Jipprovdi qari ċar f'diversi kundizzjonijiet tad-dawl.
  • Disinn Durabbli: Shockproof, dustproof, and dampness-proof construction.
Labeled components of the WOOXGEHM T6125 Insulation Resistance Tester

Figure 2: Front panel layout and key components of the T6125.

  • Vol Għolitage Output Black Negative Jack: Connects the negative test lead for high voltage testijiet.
  • Vol Għolitage Output Red Positive Jack: Connects the positive test lead for high voltage testijiet.
  • Resistor Red Positive Jack: Connects the positive test lead for resistance measurements.
  • Resistive Black Negative Jack: Connects the negative test lead for resistance measurements.
  • 12V Power Input Jack: Għal provvista ta' enerġija esterna.
  • Display LCD: Shows measurement readings and status.
  • Buttuna tat-test: Jibda kejl.
  • Buttuna taż-Żamma tad-Data: Jiffriża l-wiri kurrenti.
  • Buttuna Backlight: Activates/deactivates the LCD backlight.
  • DAR (Absorption Ratio) / PI (Polarization Index) Button: Selects DAR or PI measurement mode.
  • Gear Rotary Switch: Selects measurement function and test voltage.
WOOXGEHM T6125 with automatic shutdown feature indicated

Figure 3: The T6125 features an automatic shutdown function after 30 minutes of inactivity to conserve battery life.

5. Setup

5.1 Installazzjoni tal-batterija

The T6125 requires 8 x 1.5V AA batteries (not included).

  1. Sib il-kompartiment tal-batterija fuq wara tal-unità.
  2. Iftaħ l-għatu tal-kompartiment tal-batterija.
  3. Daħħal 8 batteriji AA, filwaqt li tiżgura polarità korretta (+/-).
  4. Agħlaq l-għatu tal-kompartiment tal-batterija sew.

5.2 Konnessjoni tal-wajers tat-test

Connect the test leads to the appropriate jacks on the front panel based on the measurement type. For insulation resistance tests, use the High Voltage Output jacks. For low resistance, use the Resistor jacks.

6. Istruzzjonijiet Operattivi

6.1 Power On/Off

Rotate the Gear Rotary Switch from the "OFF" position to any measurement function to power on the device. Rotate back to "OFF" to power off. The device will automatically shut down after 30 minutes of inactivity.

6.2 Kejl tar-Reżistenza għall-Insulazzjoni

This function measures the insulation resistance of electrical equipment.

  1. Kun żgur li ċ-ċirkwit li qed jiġi ttestjat ma jkollux l-enerġija u ma jiġix skarkat b'mod sikur.
  2. Connect the test leads to the High Voltage Output jacks (red to positive, black to negative).
  3. Connect the other ends of the test leads to the insulation points of the equipment to be tested.
  4. Rotate the Gear Rotary Switch to the desired insulation test voltage (e.g., 100V, 250V, 500V, 1000V, 2500V).
  5. Agħfas u żomm il- TEST button. The measurement will begin, and the resistance value will be displayed on the LCD.
  6. Irrilaxxa l- TEST button to stop the measurement. The instrument will automatically discharge the circuit.
  7. To hold the reading, press the ŻOMM button during or after a measurement. Press again to release.
WOOXGEHM T6125 displaying insulation resistance measurement range

Figure 4: The T6125 offers a wide insulation test measurement range up to 2500V and 200.0GΩ.

6.3 Absorption Ratio (DAR) and Polarization Index (PI) Measurement

DAR and PI are used to assess the quality of insulation over time.

  1. Follow steps 1-3 for Insulation Resistance Measurement.
  2. Rotate the Gear Rotary Switch to the desired insulation test voltage.
  3. Agħfas il- DAR/PI button to select the desired mode. The display will indicate "DAR" or "PI".
  4. Agħfas u żomm il- TEST button. The instrument will automatically perform the timed measurements and display the DAR or PI value.
  5. Irrilaxxa l- TEST buttuna.

6.4 AC Voltage Kejl

Biex tkejjel AC voltage:

  1. Rotate the Gear Rotary Switch to the "ACV" position.
  2. Connect the test leads to the circuit where AC voltage needs to be measured.
  3. L-AC voltage se jintwera fuq l-LCD.

6.5 Kejl ta 'Reżistenza Baxxa

For continuity or low resistance checks:

  1. Rotate the Gear Rotary Switch to the "Ω" (low resistance) position.
  2. Connect the test leads to the Resistor jacks.
  3. Connect the other ends of the test leads to the component or circuit to be measured.
  4. The resistance value will be displayed on the LCD.

7. Manutenzjoni

7.1 Tindif

Imsaħ l-istrument ma adamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the instrument is completely dry before storage or next use.

7.2 Ħażna

When not in use for extended periods, remove the batteries to prevent leakage. Store the instrument in the provided cloth bag in a cool, dry place, away from direct sunlight and extreme temperatures.

  • Temperatura tal-Ħażna: -20℃ sa 60℃
  • Working Conditions: 0℃ to 40℃
  • Umdità Relattiva: 40% sa 75%

8 Issolvi l-problemi

If you encounter issues with your WOOXGEHM T6125, refer to the following common problems and solutions:

  • Ebda Qawwa:
    • Iċċekkja jekk il-batteriji humiex installati sew u għandhomx biżżejjed ċarġ. Ibdelhom jekk meħtieġ.
    • Ensure the Gear Rotary Switch is not in the "OFF" position.
  • Qari mhux eżatt:
    • Verify test leads are securely connected and not damaged.
    • Ensure the correct measurement function and test voltage are selected.
    • Clean the test points on the equipment being measured.
    • Check for external interference sources.
  • "OL" or Over-range Display:
    • The measured value exceeds the selected range. Try a higher test voltage or a different range if applicable.
    • Ensure proper connection to the circuit.

Jekk il-problema tippersisti, ikkuntattja l-appoġġ tal-klijent.

9. Speċifikazzjonijiet

Speċifikazzjonijiet Ġenerali
MudellT6125
MaterjalABS
Provvista tal-Enerġija8 x 1.5V batteriji AA (Mhux inklużi)
Daqs tal-Oġġett179 x 133 x 70 mm (7.04 x 5.23 x 2.75 pulzieri)
Piż tal-oġġett570 g (1.25 lb)
Temperatura tal-Ħażna-20℃ sa 60℃
Kundizzjonijiet tax-Xogħol0℃ sa 40℃
Altitudni2000m
Umdità Relattiva40% sa 75%

Insulation Test Accuracy (T-6125)

Ħruġ VoltageLi jvarjawRiżoluzzjoniKurrent Massimu tat-TestEżattezza
250V (± 10%)0 ~ 20MΩ0.01MΩ2mA±(3%+5)
20 ~ 200MΩ0.1MΩ±(3%+5)
0.2G~2GΩ0.001GΩ±(10%+5)
500V (± 10%)0 ~ 20MΩ0.01MΩ2mA±(3%+5)
20 ~ 200MΩ0.1MΩ±(3%+5)
0.2G~2GΩ0.001GΩ±(10%+5)
1000V (± 10%)0 ~ 20MΩ0.01MΩ2mA±(3%+5)
20 ~ 200MΩ0.1MΩ±(3%+5)
0.2G~2GΩ0.001GΩ±(10%+5)
2500V (± 10%)0 ~ 20MΩ0.01MΩ2mA±(3%+5)
20 ~ 200MΩ0.1MΩ±(5%+5)
0.2G~2GΩ0.001GΩ±(10%+5)
2G~20GΩ0.01GΩ±(10%+5)
AC Voltage PreċiżjoniRanging: 600VRiżoluzzjoni: 1VN/A±(1.5%+5)
Preċiżjoni tar-reżistenzaRanging: 60ΩRiżoluzzjoni: 0.01ΩN/A±(1.2%+5)
Table showing insulation test accuracy for WOOXGEHM T6125

Figure 5: Detailed insulation test accuracy specifications for the T6125 model.

Dimensions of the WOOXGEHM T6125 Insulation Resistance Tester

Figure 6: Physical dimensions of the WOOXGEHM T6125.

10. Garanzija u Appoġġ

For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official WOOXGEHM websit. Żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri.

© 2024 WOOXGEHM. All rights reserved.