1. Introduzzjoni
The Ortis Hi-Lo Sump Pump Switch Controller KJ-033 is an electronic adjustable float switch designed for automatic water level management in various applications such as sewage pits, fish tanks, and water tanks. It features stainless steel anti-corrosion dual sensors and supports both 220V and 110V AC power inputs. This manual provides detailed instructions for installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.
2. Informazzjoni dwar is-Sigurtà
Jekk jogħġbok aqra l-istruzzjonijiet kollha tas-sigurtà bir-reqqa qabel l-installazzjoni u t-tħaddim. Jekk ma ssegwix dawn l-istruzzjonijiet, dan jista' jirriżulta f'xokk elettriku, nar, jew korriment serju.
- Periklu Elettriku: Kun żgur li l-provvista tal-enerġija hija skonnettjata qabel ma twettaq kwalunkwe installazzjoni, manutenzjoni, jew issolvi l-problemi.
- Voltage Kompatibilità: Ivverifika li l-provvista tal-enerġija voltage matches the controller's specifications (220V/110V AC).
- L-ert kif suppost: Dejjem qabbad l-apparat ma' sokit ertjat kif suppost.
- Espożizzjoni għall-Ilma: Do not immerse the controller unit in water. The controller unit is designed to be mounted above the water level.
- Persunal kwalifikat: Installation and electrical connections should be performed by qualified personnel if you are unsure.
- Kundizzjonijiet Ambjentali: Do not operate the device in explosive atmospheres or where flammable liquids or gases are present.
3. Karatteristiċi tal-prodott
The Ortis KJ-033 controller offers several features for reliable water level management:
- Dual Stainless Steel Sensors: Anti-corrosion sensors for accurate water level detection.
- Adjustable Sensor Range: Sensors can be adjusted from 1/2 inch to 20 inches to define high and low water levels.
- Modi Operattivi Multipli: Supports Drain Mode (for emptying) and Water Mode (for filling).
- Indikaturi LED: Visual feedback for power, load status, and alarm conditions.
- Protezzjoni ta' tagħbija żejda: Integrated protection for connected pumps.
- Funzjoni Mute: Allows silencing of the alarm.
- Applikazzjoni wiesgħa: Suitable for sewage pits, fish tanks, water tanks, and other water management systems.

Figura 3.1: Ortis Water Level Controller Overview b'Karatteristiċi Ewlenin.

Figura 3.2: Various Application Scenarios for the Controller.
4. Setup u Installazzjoni
Proper installation is crucial for the reliable operation of the controller.
4.1 Immuntar tal-Kontrollur
The controller unit should be mounted in a dry location, above the maximum water level, and within reach of a grounded power outlet.
- Immuntar bil-kamin: Use appropriate screws and anchors to secure the controller to a wall or stable surface through the mounting tabs.
- Immuntar tat-tazza tal-ġbid: For temporary or non-permanent installations, a suction cup can be used to attach the controller to a smooth, clean surface.

Figura 4.1: Controller Installation Methods.
4.2 Sensor Installation and Adjustment
The dual sensors detect the high and low water levels. Their position determines the operating range of your pump.
- Tqegħid tas-Sensor: Position the sensors vertically in the water, ensuring they are securely fastened and will not move. The lower sensor defines the 'low' water level, and the upper sensor defines the 'high' water level.
- Medda aġġustabbli: The sensors can be adjusted along their cables to set the desired water level range, from 1/2 inch to 20 inches apart. Ensure both sensors are submerged at the desired 'on' level and the lower sensor is exposed at the desired 'off' level for drain mode, or vice versa for water mode.
- Ġestjoni tal-Kejbil: Route sensor cables to prevent entanglement or damage.

Figura 4.2: Adjustable Sensor Installation.
4.3 Konnessjoni Elettrika
- Ipplaggja l-Enerġija: Plug the controller's power cord into a grounded 220V or 110V AC outlet.
- Konnessjoni tal-Pompa: Plug your sump pump or other load device into the outlet on the front of the controller. Ensure the pump's power requirements do not exceed the controller's output capacity (15A, up to 2HP).

Figura 4.3: Example Sump Pit Installation.
5. Istruzzjonijiet Operattivi
The controller features a simple interface for selecting operating modes and managing alarms.

Figura 5.1: Control Panel Matulview.
5.1 Għażla tal-Modalità
Use the 'Drain' and 'Water' buttons to select the desired operating mode:
- Modalità Ixxotta: (LED indicator 'Drain' illuminates) In this mode, the controller activates the pump when the water level reaches the upper (high) sensor and deactivates it when the water level drops below the lower (low) sensor. This mode is typically used for emptying sewage pits or sumps.
- Modalità Ilma: (LED indicator 'Water' illuminates) In this mode, the controller activates the pump when the water level drops below the lower (low) sensor and deactivates it when the water level reaches the upper (high) sensor. This mode is typically used for replenishing water in fish tanks or water tanks.
5.2 Power and Operation Switch
The main switch controls the power and operational state of the connected load:
- AUTO: (LED indicator 'AUTO' illuminates) The controller operates automatically based on the selected mode (Drain or Water) and sensor readings.
- MITFI: (LED indicator 'OFF' illuminates) The connected pump is turned off, regardless of water levels.
- FUQ: (LED indicator 'ON' illuminates) The connected pump is continuously turned on, regardless of water levels. Use this for manual override or continuous operation.
5.3 Funzjoni Mute
Press the 'Mute' button to silence any active alarms. The 'DisAlarm' LED will illuminate when the alarm is muted.

Figura 5.2: Operational Logic in Drain Mode (Sewage Pit Example).
6. Manutenzjoni
Regular maintenance ensures the longevity and reliable operation of your Ortis controller.
- Tindif tas-Sensor: Periodically inspect and clean the stainless steel sensors to remove any buildup of debris, algae, or mineral deposits that could affect their accuracy. Disconnect power before cleaning.
- Spezzjoni tal-Cable: Check all cables and connections for signs of wear, damage, or corrosion. Replace any damaged components immediately.
- Controller Unit: Keep the controller unit clean and dry. Avoid exposing it to direct sunlight or extreme temperatures.
- Operazzjoni tat-Test: Periodically test the controller's operation by manually raising or lowering water levels to ensure the pump activates and deactivates as expected in the selected mode.
7 Issolvi l-problemi
Irreferi għat-tabella t'hawn taħt għal kwistjonijiet komuni u s-soluzzjonijiet tagħhom.
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Pump does not turn on/off automatically. | 1. Controller not in AUTO mode. 2. Sensors are dirty or improperly positioned. 3. Pump is not plugged in or is faulty. | 1. Ensure the switch is set to 'AUTO'. 2. Clean sensors and verify their high/low positions. 3. Check pump connection and functionality. |
| L-allarm jinstema' ta' spiss. | 1. Water level not reaching desired sensor within expected time. 2. Malfunzjoni tas-sensor. 3. Alarm sensitivity setting (if applicable, check product documentation). | 1. Check pump operation and water flow. Adjust sensor positions if needed. 2. Inspect sensors for damage or debris. Replace if faulty. 3. Use the 'Mute' button temporarily. Consult manufacturer for alarm logic details. |
| Il-kontrollur m'għandux poter. | 1. Korda tal-enerġija splaggjata. 2. L-iżbokk m'għandux qawwa. 3. Fjus intern minfuħa. | 1. Ensure power cord is securely plugged in. 2. Test the outlet with another device. Check circuit breaker. 3. Ikkuntattja l-appoġġ tal-klijent għall-għajnuna. |
| Pump runs continuously in AUTO mode. | 1. Sensor stuck in 'on' position (e.g., upper sensor always wet in Drain Mode). 2. Controller malfunction. | 1. Clean and reposition sensors. Ensure they can freely detect water level changes. 2. Disconnect power and reconnect. If issue persists, contact support. |
8. Speċifikazzjonijiet

Figura 8.1: Controller Dimensions.
| Karatteristika | Speċifikazzjoni |
|---|---|
| Mudell | KJ-033 |
| Brand | Ortis |
| Input Voltage | 220V / 110V AC |
| Kurrent tal-Ħruġ | 15A |
| Qawwa tat-Tagħbija massima | Sa 2 HP |
| Materjal tas-Sensor | Stainless Steel |
| Adjustable Sensor Range | 1/2 inch to 20 inches |
| Manifattur | FJKJ INC. |
9. Garanzija u Appoġġ
For warranty information and technical support, please refer to the product packaging or contact the seller/manufacturer directly. Keep your purchase receipt as proof of purchase.