IBO MAGI 2

IBO Magi 2 25-60/180 High-Efficiency Circulation Pump User Manual

Model: MAGI 2 | Brand: IBO

1. Introduzzjoni

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IBO Magi 2 25-60/180 High-Efficiency Circulation Pump. Please read these instructions carefully before installation and use, and keep them for future reference.

2. Prodott Aktarview

The IBO Magi 2 25-60/180 is a high-efficiency centrifugal circulation pump designed for various heating and circulation systems. It features a permanent magnet motor and a differential pressure regulator that automatically and continuously adjusts the pump's power to meet the system's actual demands. The control panel is conveniently located on top of the motor, displaying current power consumption for easy monitoring.

The MAGI series circulation pump is ideally suited for the following systems:

  • Constant temperature heating systems with variable flow.
  • Heating systems with variable pipe temperature.
  • Heating systems with night mode.
  • Air conditioning systems.
  • Industrial circulation systems.
  • Central heating and domestic hot water systems.
IBO Magi 2 25-60/180 Circulation Pump

Figura 2.1: Ġenerali view of the IBO Magi 2 25-60/180 Circulation Pump.

3. Komponenti Inklużi

Meta tiftaħ il-pakkett, kun żgur li l-komponenti kollha li ġejjin huma preżenti:

  • IBO Magi 2 25-60/180 Circulation Pump
  • Kit twaħħil bil-kamin
  • Gaskits
  • Kejbil tal-enerġija bil-plagg
Screw fittings and gaskets for IBO Magi 2 pump

Figure 3.1: Included screw fittings and gaskets.

Power cable with plug for IBO Magi 2 pump

Figure 3.2: Power cable with plug.

4. Setup u Installazzjoni

Installation should be performed by a qualified professional in accordance with local regulations and safety standards.

4.1. Immuntar tal-Pompa

  1. Kun żgur li s-sistema tkun mingħajr pressjoni u mbattla qabel l-installazzjoni.
  2. Immonta l-pompa f'pożizzjoni orizzontali bix-xaft tal-mutur orizzontali.
  3. Use the provided screw fittings and gaskets to connect the pump to the piping system. Ensure a watertight seal.
  4. Observe the flow direction indicated by the arrow on the pump housing.

4.2. Konnessjoni Elettrika

  1. Connect the provided power cable to the pump's electrical terminal.
  2. Kun żgur li l-provvista tal-enerġija taqbel mal-volum nominali tal-pompatage (230 V/50 Hz).
  3. Ipplaggja l-kejbil tal-enerġija f'sokit elettriku adattat bl-ert.
  4. Verify all electrical connections are secure and insulated.

5. Modi Operattivi

The IBO MAGI 2 circulation pump offers several operating modes, accessible via the control panel on top of the motor. The current power consumption is displayed on the dial.

Control panel of IBO Magi 2 pump showing display and buttons

Figure 5.1: Control panel displaying operating modes and power consumption.

Available operating modes:

  • Modalità Awtomatika: Automatically selects pump parameters based on installation requirements.
  • Proportional Pressure Curves: BL1, BL2 (adjusts head proportionally to flow).
  • Constant Pressure Curves: HD1, HD2 (maintains a constant differential pressure).
  • Constant Speed Characteristics: HS1, HS2, HS3 (operates at a fixed speed).

Refer to the control panel interface for selecting and adjusting these modes according to your system's needs.

6. Manutenzjoni

Regular maintenance ensures optimal performance and extends the lifespan of your circulation pump. Always disconnect the pump from the power supply before performing any maintenance.

6.1. Spezzjoni Ġenerali

  • Periodically check for any leaks around the pump and connections.
  • Inspect the power cable for signs of damage or wear.
  • Ensure the pump is free from excessive dirt or debris.

6.2. Tindif

If necessary, clean the exterior of the pump with a damp drapp. Tużax tindif jew solventi li joborxu.

6.3. System Flushing

Ensure the heating or circulation system is regularly flushed to prevent the buildup of sludge and debris, which can affect pump performance.

7 Issolvi l-problemi

Qabel ma tikkuntattja l-appoġġ tekniku, review il-kwistjonijiet komuni li ġejjin u s-soluzzjonijiet potenzjali tagħhom.

ProblemaKawża PossibbliSoluzzjoni
Il-pompa ma tibdaxEbda provvista ta 'enerġijaCheck power connection, fuse, and circuit breaker.
Il-pompa taħdem imma l-ebda flussArja fis-sistemaBleed the system to remove air.
Fluss jew pressjoni mnaqqsaClogged impeller or pipingInspect and clean the impeller and system piping.
Ħoss mhux tas-soltuArja fil-pompa jew fis-sistemaBleed the system. Check for cavitation.
TnixxijaLoose connections or damaged gasketsTighten connections or replace gaskets.

Jekk il-problema tippersisti wara li tipprova dawn is-soluzzjonijiet, jekk jogħġbok ikkuntattja persunal tas-servizz kwalifikat.

8. Speċifikazzjonijiet

ParametruValur
MudellMAGI 2 25-60/180
Vol ikklassifikattage230V/50Hz
Konsum tal-Enerġija5-45 W
Max Rata tal-Fluss55 Litri kull minuta
Max Head (Height of lift)6-il metru
Pressjoni Operattiva Massima10 bar
Temperatura operattiva+2 °C / +110 °C
Port-to-Port Distance180 mm
Dijametru tal-Konnessjoni1 1/2" - 1"
Indiċi tal-ProtezzjoniIP44
Dimensjonijiet (L x W x H)20 x 20 x 15 ċm
Piż2.98 kg
ManifatturPHU Dambat

9. Informazzjoni dwar Garanzija

This product is covered by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms, conditions, and duration. Keep your proof of purchase for any warranty claims.

10. Appoġġ u Kuntatt

For technical assistance, spare parts, or further inquiries, please contact your retailer or the manufacturer directly. Ensure you have your product model number (MAGI 2) and purchase details available when seeking support.

Manufacturer: PHU Dambat

Websit: www.dambat.pl

© 2026 IBO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.