OWON OW18E

OWON OW18E Digital Multimeter User Manual

Model: OW18E | Brand: OWON

1. Introduzzjoni

The OWON OW18E is a high-precision 4½ digit digital multimeter designed for accurate electrical measurements. With a 20,000-count display and True RMS capability, it provides reliable readings for various waveforms. This device integrates Bluetooth 4.0 for wireless data transfer and logging, enhancing efficiency in diverse applications such as research, manufacturing, and maintenance. Its robust design, safety features, and user-friendly functions make it an essential tool for professionals and enthusiasts.

OWON OW18E Multimeter with key features highlighted

Image 1.1: OWON OW18E Multimeter highlighting its 4½ digit, 20000 counts, True RMS, Bluetooth, Data-logging, AC/DC Current, Diode Test, Capacitance, Temperature, Frequency, Continuity Buzzer, AC/DC Voltage, and Non-Contact Voltage Detect features.

2. Informazzjoni dwar is-Sigurtà

Always adhere to safety precautions when using the OWON OW18E Digital Multimeter to prevent electric shock or damage to the device. This multimeter is designed to meet safety standards, but improper use can still lead to hazards.

  • Do not exceed the maximum input limits for any measurement range.
  • Ensure test leads are properly connected and in good condition before making measurements.
  • Avoid touching exposed conductors or circuit components while power is applied.
  • Uża l-Volum Mingħajr Kuntatttage (NCV) function to detect live wires before making contact.
  • Ibdel il-batteriji minnufih when the low battery indicator appears to ensure accurate readings and proper operation.
  • Do not operate the multimeter if it appears damaged or if the case is open.
  • Refer to the complete safety guidelines in the detailed user manual available on the OWON official websit.

3. Prodott Aktarview u Komponenti

Familiarize yourself with the main components of your OWON OW18E Digital Multimeter.

Quddiem view of OWON OW18E Multimeter with labeled parts

Stampa 3.1: Quddiem view of the OWON OW18E Multimeter, showing the LCD display, Rotary Switch, Bluetooth/Backlight Buttons, Non-Contact Voltage Detect area, Flashlight, 20A current input terminal, mA µA input terminal, V/Ω/Hz/(t)/°C input terminal, and COM input terminal.

Lura view of OWON OW18E Multimeter with labeled parts and accessories

Immaġni 3.2: Wara view of the OWON OW18E Multimeter, illustrating the Insulated non-slip case, Test Lead Slot, Retractable Stand, Fuse and 1.5V battery compartment. Insets show the high definition backlit LCD, rotary switch with accurate scale, smooth and fastened sockets, Non-Contact Voltage Detect area, protective sleeve, and storage slot for test leads.

4. Setup

Before using your multimeter, ensure it is properly set up.

4.1 Installazzjoni tal-batterija

  1. Kun żgur li l-multimetru huwa MITFI.
  2. Locate the battery compartment on the back of the device (refer to Image 3.2).
  3. Uża tornavit biex tiftaħ il-qoxra tal-batterija.
  4. Insert the required 1.5V batteries (or 9V battery if applicable, as shown in Image 8.1) according to the polarity markings.
  5. Agħlaq sewwa l-għatu tal-batterija.

4.2 Konnessjoni tal-wajer tat-test

  1. Connect the black test lead to the 'COM' input terminal.
  2. Connect the red test lead to the appropriate input terminal based on the measurement function:
    • Għal Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, and Temperature measurements, connect the red lead to the 'V/Ω/Hz/(t)/°C' terminal.
    • For mA or µA current measurements, connect the red lead to the 'mA µA' terminal.
    • For 20A current measurements, connect the red lead to the '20A' terminal.
  3. Kun żgur li l-konnessjonijiet kollha huma sodi u siguri.

5. Istruzzjonijiet Operattivi

This section details how to perform various measurements and utilize the multimeter's functions.

5.1 Kejl Bażiku

  1. VoltagKejl tal-e (AC/DC):
    Dawwar is-swiċċ rotatorju għall-'V~' (Volum ACtage) jew 'V-' (Volum DCtage) position. Connect the test leads in parallel to the circuit or component to be measured. The reading will appear on the LCD.
  2. Kejl tal-Kurrent (AC/DC):
    Turn the rotary switch to the 'A~' (AC Current) or 'A-' (DC Current) position, selecting the appropriate range (µA, mA, or 20A). Connect the test leads in series with the circuit.
  3. Kejl tar-Reżistenza:
    Turn the rotary switch to the 'Ω' position. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance.
  4. Kejl tal-Kapaċitanza:
    Turn the rotary switch to the 'F' (Capacitance) position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.
  5. Kejl tat-Temperatura:
    Turn the rotary switch to the '°C/°F' position. Connect the K-type thermocouple (included) to the input terminals. The temperature will be displayed.
  6. Frequency (Hz) Measurement:
    Turn the rotary switch to the 'Hz' position. Connect the test leads to the signal source.
  7. Test tad-Diode:
    Turn the rotary switch to the 'Diode' symbol position. Connect the red lead to the anode and the black lead to the cathode of the diode. The forward voltagse tintwera e drop.
  8. Test ta' Kontinwità:
    Turn the rotary switch to the 'Continuity' symbol position. Connect the test leads across the circuit or component. A buzzer will sound if continuity is detected.

5.2 Funzjonijiet Speċjali

  • RMS Veru: The OW18E features True RMS measurement, providing accurate readings for both sinusoidal and non-sinusoidal AC waveforms.
  • Mhux Kuntatt VoltagSejbien ta' e (NCV): Activate the NCV function to detect the presence of AC voltage without direct contact. The strength indicator will illuminate, and an audible alarm will sound if voltage jiġi skopert.
  • Dawl ta' wara: Press the backlight button to illuminate the LCD for improved visibility in low-light conditions.
  • Żamma tad-Data: Agħfas il-buttuna 'HOLD' biex tiffriża l-qari attwali fuq id-displej. Agħfas mill-ġdid biex tirrilaxxa.
  • Relative Value Measurement: This function allows you to measure the difference between a current reading and a stored reference value.
  • Flashlight: The built-in flashlight can be activated to illuminate the work area.
Multimeter demonstrating NCV, temperature, and flashlight functions, and calibration

Image 5.1: The OWON OW18E demonstrating Non-Contact Voltage Detect, Temperature Measurement with non-contact thermocouple, and the built-in Flashlight. Also shown are calibration tests for standard voltage, resistance, and current measurements.

5.3 Bluetooth Connectivity and Data Logging

The OW18E supports Bluetooth 4.0 for wireless communication with smartphones or PCs, enabling real-time data transfer and logging.

Bluetooth function showing real-time data transfer to smartphone and PC

Image 5.2: Bluetooth function introduction, showing voice broadcast measurement support and stable Bluetooth 4.0 transmission for real-time display on mobile phones and PCs. A Bluetooth USB dongle (optional) may be required for PC connection.

Multimeter app interface for data logging and analysis

Image 5.3: The OWON OW18E functioning as a data-logger, with its app interface displaying logged values in charts and tables. The record interval can be adjusted (default >0.5s). The image also illustrates simultaneous measurement of multiple data sets for analysis and comparison.

5.3.1 Offline Recording Function

App interface for setting and downloading offline recorded data

Image 5.4: The app interface for the offline recording function. It shows how to set the sample interval (1 to 4,200,000 seconds) and the number of recording points (0 to 10,000 points). After recording, the data is saved in the multimeter's internal memory and can be downloaded to the mobile app for analysis. If the battery is low, the meter will shut down for data protection before the data is downloaded.

For detailed instructions on using the Bluetooth app, please refer to the App Installation Guide included with your product or download the full user manual from the OWON official websit: http://www.owon.com.hk/bluetooth4

6. Manutenzjoni

Manutenzjoni xierqa tiżgura l-lonġevità u l-preċiżjoni tal-multimetru tiegħek.

  • Tindif: Uża artab, damp cloth to clean the exterior of the multimeter. Do not use abrasive cleaners or solvents.
  • Sostituzzjoni tal-batterija: Replace batteries as soon as the low battery indicator appears to prevent inaccurate readings or device shutdown during critical measurements. Refer to Section 4.1 for battery installation.
  • Sostituzzjoni tal-fjus: If the current measurement function fails, the fuse may need replacement. Refer to the detailed manual for instructions on accessing and replacing the fuse. Always use a fuse of the specified type and rating.
  • Ħażna: When not in use for extended periods, remove the batteries and store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures.

7 Issolvi l-problemi

If you encounter issues with your OWON OW18E, try the following troubleshooting steps:

ProblemaKawża PossibbliSoluzzjoni
L-ebda wiri jew wiri dgħajjefBatterija baxxa jew l-ebda batterija installataReplace or install new batteries.
Qari mhux korrettIncorrect range selected, poor test lead connection, or damaged test leadsEnsure correct range, check test lead connections, or replace test leads.
Il-kejl tal-kurrent mhux qed jaħdemFjus minfuħReplace the fuse with the specified type and rating.
Kwistjonijiet ta 'konnessjoni BluetoothBluetooth not enabled, app not installed, or device out of rangeEnsure Bluetooth is on, install the OWON app, and keep devices within range. For PC, ensure a Bluetooth dongle is used.

Jekk il-problema tippersisti wara li tipprova dawn is-soluzzjonijiet, jekk jogħġbok ikkuntattja l-appoġġ għall-klijenti ta' OWON.

8. Speċifikazzjonijiet

The OWON OW18E Digital Multimeter offers the following technical specifications:

KaratteristikaSpeċifikazzjoni
Għadd tal-Wiri20,000 counts (4½ digits)
RMS VeruIva
BluetoothBluetooth 4.0
Logging tad-DataUp to 10,000 points (offline recording)
AC / DC VoltageMeasurement capability included
Kurrent AC / DCMeasurement capability included (up to 20A)
ReżistenzaMeasurement capability included
KapaċitàMeasurement capability included
TemperaturaMeasurement capability included (K-type thermocouple)
FrekwenzaMeasurement capability included
Test tad-DiodeIva
Buzzer tal-KontinwitàIva
Mhux Kuntatt Voltage (NCV)Iva
Dawl ta' waraIva
FlashlightIva
Sors tal-EnerġijaAC (implied by product description, typically battery-powered for handheld)
Dimensjonijiet tal-Prodott (L x W x H)196mm x 88.5mm x 56mm
Piż Nett tal-Prodott0.32 kg
Aċċessorji InklużiMultimeter leads, K-type thermocouple, screwdriver, alligator clips, instructions, app installation guide
OWON OW18E Multimeter package contents and dimensions

Image 8.1: Product contents and dimensions. Includes the OW18E multimeter, 9V battery (optional), screwdriver, K-type thermocouple, alligator clips, multimeter leads, instructions, and app installation guide. Product dimensions are 196mm x 88.5mm x 56mm, with a net weight of 0.32 kg.

9. Garanzija u Appoġġ

OWON is committed to providing high-quality products and reliable customer support.

9.1 Informazzjoni dwar Garanzija

OWON products purchased through Amazon are covered by a standard warranty:

  • Unità Prinċipali: 3-year manufacturer's warranty.
  • Aċċessorji: 1-year warranty for modules, probes, and batteries.

9.2 Appoġġ għall-Klijent

For any inquiries, technical assistance, calibration services, repair requests, or other support needs, please contact OWON directly.

  • Uffiċjali Websit: User manuals and additional resources can be downloaded from the OWON official websit: owon.co.jp
  • Kuntatt għas-Servizz: For calibration, repair, or other service requests, please visit the OWON official website and use the contact form or provided contact information. When requesting repair, please provide your purchase route, purchase date, and model name.
  • Bulk Purchases/Demo Units: For corporate customers interested in bulk purchases or borrowing demo units, please contact OWON via their official websit.