This manual provides essential information for the proper installation, operation, and maintenance of your FTVOGUE 12V Level Control Switch Module. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

Figure 1: Two FTVOGUE 12V Level Control Switch Modules, showing the relay, capacitor, and terminal blocks from an angled top-down perspective.
2. Informazzjoni dwar is-Sigurtà
- Ensure the power supply matches the module's voltagRekwiżiti elettroniċi (12V DC).
- Skonnettja l-enerġija qabel ma tagħmel xi konnessjonijiet jew twettaq manutenzjoni.
- Avoid exposing the module to moisture, extreme temperatures, or corrosive environments.
- Installation should be performed by qualified personnel if you are unfamiliar with electrical wiring.
- Do not exceed the relay's maximum switching capacity (10A at 250VAC / 10A at 30VDC).
3. Karatteristiċi tal-prodott
The FTVOGUE 12V Level Control Switch Module offers reliable liquid level detection and control with the following features:
- Kostruzzjoni Durabbli: Made with a high-quality PCB board for low power consumption and extended lifespan.
- Prestazzjoni Stabbli: Features simple wiring, low power consumption, and high switching capacity for consistent operation.
- Installazzjoni faċli: Compact and lightweight design allows for convenient setup.
- Applikazzjoni wiesgħa: Suitable for use in various environments requiring automatic drainage or liquid level management, such as pond tanks, garages, and basements.
4. Identifikazzjoni tal-Komponent
Familiarize yourself with the key components and terminals of the module:

Figura 2: Veduta mill-qrib minn fuq view of a single FTVOGUE 12V Level Control Switch Module, highlighting the relay, PCB traces, and terminal block labels (VCC, GND, LOW, COM, HIGH, NC, NO).
- VCC: Power input (12V DC).
- GND: Konnessjoni mal-art.
- GĦOLJA: Input for the upper liquid level sensor.
- BAXX: Input for the lower liquid level sensor.
- COM (Sensor): Common connection for liquid level sensors.
- LE: Relay Normally Open contact.
- NC: Relay Normally Closed contact.
- COM (Relay): Common contact for the relay output.
5. Setup u Installazzjoni
Follow these steps to install your level control switch module:
- Immuntar: Securely mount the module in a dry, stable location away from direct moisture or excessive vibration.
- Konnessjoni tal-Enerġija: Connect a 12V DC power supply to the VCC u GND terminals. Ensure correct polarity.
- Konnessjoni tas-Sensor: Connect your liquid level sensors to the GĦOLJA, BAXXA, u COM (Sensor) terminals. The GĦOLJA terminal is for the upper level sensor, and the BAXXA terminal is for the lower level sensor. The COM (Sensor) terminal is the common connection for both sensors.
- Konnessjoni tat-Tagħbija: Connect the device you wish to control (e.g., pump, valve) to the relay output terminals: LE, NC, u COM (Relay). Choose between NO (Normally Open) or NC (Normally Closed) based on whether you want the device to activate when the relay is energized or de-energized.
- Ivverifika l-Konnessjonijiet: Iċċekkja darbtejn il-wajers kollha għall-korrettezza u l-konnessjonijiet sikuri qabel ma tapplika l-enerġija.

Figure 3: Two FTVOGUE 12V Level Control Switch Modules, viewed from a slightly different angle, emphasizing the compact size and terminal block arrangement.
6. Istruzzjonijiet Operattivi
Once properly installed and powered, the module operates as follows:
- The module continuously monitors the liquid levels via the connected sensors.
- When the liquid level reaches the GĦOLJA sensor, the relay will activate (or de-activate, depending on configuration) to control the connected load.
- When the liquid level drops below the BAXXA sensor, the relay will switch back to its original state, controlling the connected load accordingly.
- This allows for automatic control of pumps (e.g., for drainage or filling) or alarms based on predefined liquid levels.
7. Manutenzjoni
The FTVOGUE Level Control Switch Module is designed for long-term, low-maintenance operation. To ensure optimal performance:
- Periodically inspect all wiring connections to ensure they remain secure.
- Żomm il-modulu nadif u ħieles mit-trab u l-fdalijiet. Uża drapp artab u niexef għat-tindif.
- Kun żgur li l-ambjent operattiv jibqa' fil-firxiet speċifikati tat-temperatura u l-umdità.
- Regularly check the liquid level sensors for any buildup or damage that might affect their accuracy.
8 Issolvi l-problemi
If you encounter issues with your module, refer to the following troubleshooting guide:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Il-modulu mhux qed jixgħel | Provvista ta' enerġija mhux korretta voltage or polarity; loose power connections. | Verify 12V DC power supply. Check VCC and GND connections for correct polarity and tightness. |
| Ir-relay mhux qed jaqleb | Sensor malfunction; incorrect sensor wiring; liquid level not reaching trigger points. | Inspect sensors for damage or obstruction. Confirm HIGH, LOW, and COM sensor wiring. Ensure liquid levels are reaching the sensor points. |
| Connected device not activating | Incorrect load wiring (NO/NC); faulty load device; relay contacts damaged. | Check connections to NO, NC, and COM relay terminals. Test the connected device independently. If relay clicks but device doesn't work, relay contacts might be damaged (unlikely for new module). |
9. Speċifikazzjonijiet Tekniċi
| Speċifikazzjoni | Valur |
|---|---|
| Manifattur | FTVOGUE |
| Numru tal-Parti | FTVOGUEygw0nrk1qs6525-12 |
| Input Voltage | 12V DC |
| Relay Switching Capacity | 10A 250VAC / 10A 30VDC |
| Piż tal-oġġett | 2.12 uqija |
| Dimensjonijiet tal-Pakkett | 4.72 x 3.94 x 1.57 pulzieri |
| Kwantità tal-Pakkett tal-Oġġett | 1 (Note: Product is sold in 2 pieces) |
| Batteriji Meħtieġa | Nru |
| ASIN | B0B8Z9M7P9 |
| Data L-Ewwel Disponibbli | 8 ta’ Awwissu, 2022 |
10. Garanzija u Appoġġ
For warranty information or technical support, please refer to the retailer or manufacturer's official channels. Keep your purchase receipt for any warranty claims.