1. Prodott Aktarview
The SKYSHL SS101PVA is a portable optical fiber power meter designed for precise optical power measurements in telecommunication and broadband networks. It features a built-in Visual Fault Locator (VFL) and supports multiple calibration wavelengths, making it an essential tool for fiber optic technicians.

Figura 1: Quddiem view of the SKYSHL SS101PVA Optical Fiber Power Meter, showing the color display and control buttons.
Karatteristiċi ewlenin:
- Multiple Calibration Wavelengths: Supports 850nm, 1300nm, 1310nm, 1490nm, 1550nm, and 1625nm for diverse network testing.
- Built-in VFL (650nm): Integrated Visual Fault Locator for quick fiber break detection.
- Comprehensive Fiber Test Kit: Includes universal 2.5mm, SC, FC, and LC UPC adapters.
- Wiri LCD bil-Kulur ta' 2.4 pulzieri: Provides clear and intuitive data visualization with wide viewing angles and LED backlight.
- Disinn kompatt u Durabbli: Small size for portability, ergonomic design for comfortable handling, and high-strength plastic casing for durability against drops.
2. Kontenut tal-Pakkett
Iċċekkja li l-oġġetti kollha elenkati hawn taħt huma inklużi fil-pakkett tiegħek. Jekk xi oġġetti huma neqsin jew bil-ħsara, jekk jogħġbok ikkuntattja l-appoġġ għall-klijenti.
- 1x SKYSHL SS101PVA Optical Fiber Power Meter
- 1x Universal 2.5mm Connector
- 1x SC Adapter
- 1x FC Adapter
- 1x SC-LC Connector
- 1x Backpack Strap
- 1x Manwal għall-Utent
- 1x Oxford Bag
- 3x Batteriji AA (inklużi)

Figura 2: All components included in the SKYSHL SS101PVA package.
3. Layout tal-Apparat
Familiarize yourself with the various parts and controls of your SS101PVA device.
Vidjo 1: Dan il-filmat jipprovdi viżwali fuqview of the SKYSHL SS101PVA, highlighting its key components such as the optical power meter port, VFL port, power button, and various function buttons. It also shows the battery compartment and different connector types.
Panel ta' quddiem:
- Wiri LCD bil-kulur: Shows measurement results, selected wavelength, reference value, VFL status, and battery level.
- Buttuna POWER: Ixgħel/itfi l-apparat.
- λ (Wavelength) Button: Cycles through available wavelengths (850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm).
- REF Button: Sets the current power reading as the reference value (0dB).
- dBm/dB/mW Button: Toggles between absolute power (dBm, mW) and relative power (dB) measurement units.
- VFL Button: Activates/deactivates the Visual Fault Locator.
Panel ta 'Fuq:
- Port tal-OPM: Optical Power Meter input port for fiber connection.
- Port tal-VFL: Visual Fault Locator output port.
Panel ta 'wara:
- Kompartiment tal-batterija: Houses 3 AA batteries.

Figura 3: Ġenb view of the device showing the OPM and VFL ports with protective caps and various adapters.

Figura 4: Wara view of the device with the battery compartment open, showing the slots for AA batteries.
4. Setup
4.1 Installazzjoni tal-batterija
- Sib il-kompartiment tal-batterija fuq wara tal-apparat.
- Żerżaq l-għatu tal-batterija miftuħ.
- Daħħal tliet (3) batteriji AA, waqt li tiżgura l-polarità korretta (+/-).
- Agħlaq l-għatu tal-batterija sew.
4.2 Attaching Fiber Optic Connectors
The SS101PVA comes with various interchangeable adapters. Select the appropriate adapter for your fiber optic cable.
- Remove the dust cap from the OPM or VFL port.
- Screw the desired adapter (e.g., SC, FC, LC, or universal 2.5mm) onto the port until it is finger-tight. Do not overtighten.
- Carefully insert the fiber optic cable connector into the adapter.

Figura 5: The SS101PVA device shown with its various interchangeable fiber optic adapters.
5. Istruzzjonijiet Operattivi
5.1 Power On/Off
- Biex tixgħel l-apparat, agħfas u żomm il- QAWWA Agħfas il-buttuna sakemm l-iskrin jixgħel.
- Biex itfi l-apparat, agħfas u żomm il- QAWWA buttuna sakemm l-iskrin jintefa.
5.2 Optical Power Measurement (OPM)
- Ixgħel l-apparat.
- Connect the fiber optic cable to the OPM port using the appropriate adapter.
- Agħfas il- λ button to select the desired measurement wavelength (e.g., 1310nm, 1550nm). The selected wavelength will be displayed on the screen.
- The optical power reading will be displayed in real-time.
- To change the measurement unit (dBm, dB, mW), press the dBm/dB/mW buttuna.
- To set a reference value for relative measurements (dB), press the REF button. The current power reading will be set as 0dB, and subsequent measurements will show the relative loss or gain.

Figura 6: The device's color display showing optical power measurements at different wavelengths.
5.3 Visual Fault Locator (VFL) Operation
- Ixgħel l-apparat.
- Connect the fiber optic cable to the VFL port using the appropriate adapter.
- Agħfas il- VFL button to activate the red laser. The VFL status will be indicated on the display.
- Observe the fiber for any visible red light leakage, which indicates a break or fault in the fiber.
- Agħfas il- VFL button again to turn off the laser.
Twissija: Do not look directly into the VFL output port or the end of a fiber connected to the VFL, as the laser light can cause eye damage.
6. Manutenzjoni
6.1 Cleaning Fiber Optic Connectors
Regular cleaning of fiber optic connectors is crucial for accurate measurements and to prevent damage.
- Dejjem itfi l-apparat qabel ma tnaddaf.
- Use a specialized fiber optic cleaning tool (e.g., one-click cleaner, lint-free wipes with isopropyl alcohol) to clean the connector end-faces.
- Clean both the adapter on the device and the fiber optic cable connector.
- Replace dust caps on ports when not in use to prevent contamination.
6.2 Sostituzzjoni u Ħażna tal-Batterija
- Ibdel il-batteriji meta jidher l-indikatur ta' batterija baxxa fuq id-displej.
- Jekk l-apparat ma jkunx se jintuża għal perjodu twil ta' żmien, neħħi l-batteriji biex tevita t-tnixxija u l-ħsara.
- Store the device in its Oxford bag in a cool, dry place, away from direct sunlight and extreme temperatures.
7 Issolvi l-problemi
Kwistjonijiet Komuni u Soluzzjonijiet:
- L-apparat ma jixgħelx:
- Iċċekkja jekk il-batteriji humiex installati sew u għandhomx biżżejjed ċarġ. Ibdelhom jekk meħtieġ.
- Ensure the POWER button is pressed and held for a few seconds.
- Inaccurate OPM readings:
- Clean all fiber optic connectors and adapters thoroughly.
- Ensure the correct wavelength is selected for the measurement.
- Verify that the fiber connection is secure and free from bends or damage.
- VFL not working:
- Iċċekkja l-livell tal-batterija.
- Ensure the fiber is properly connected to the VFL port.
- Clean the VFL port and fiber connector.
- Id-displej huwa mċajpar jew ma jistax jinqara:
- Adjust screen brightness if available (refer to device settings, though not explicitly mentioned for this model).
- Ensure sufficient battery power.
8. Speċifikazzjonijiet
| Karatteristika | Speċifikazzjoni |
|---|---|
| Brand | SKYSHL |
| Numru tal-Mudell | SS101PVA |
| Numru tal-Parti | SS101PVA-1 |
| Medda ta' Kejl | 800nm ~ 1700nm |
| Firxa tal-Kejl tal-Enerġija | -70 ~ + 8dBm |
| Calibrated Wavelengths | 850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm |
| Tul tal-mewġa tal-VFL | 650nm |
| Konnetturi Inklużi | Universal 2.5mm, SC, FC, LC UPC Adapter |
| Wiri | LCD bil-kulur ta' 2.4 pulzieri |
| Sors tal-Enerġija | 3x Batteriji AA (inklużi) |
| Materjal | Plastic (device casing), Oxford (bag) |
| Kulur | Aħmar + Iswed |
| Dimensjonijiet (L x W x H) | 17.5 x 7.5 x 4 ċm |
| Piż | 320 g |
| Użi Speċifiċi | Ittestjar tal-fibra |
9. Garanzija u Appoġġ
SKYSHL products are manufactured to high-quality standards and undergo rigorous testing. For warranty information and technical support, please refer to the contact details below.
Appoġġ għall-Klijent:
- Email: af@skyshl.net (Available 7x24h)
- Ħanut tal-Marka: Żur l-uffiċjal SKYSHL Store on Amazon għal aktar prodotti u informazzjoni.