Newhouse Hardware CHIMEBASE2

Newhouse Hardware CHIMEBASE2 Doorbell Chime Mechanism Instruction Manual

Model: CHIMEBASE2

1. Introduzzjoni u Fuqview

The Newhouse Hardware CHIMEBASE2 is a doorbell chime mechanism designed as a replacement or new installation component for wired doorbell systems. This unit provides two distinct chime melodies: a 2-note chime for the front door and a single-note chime for the back door, enabling clear identification of which door requires attention. Please note that this product includes only the chime mechanism base; the decorative cover is sold separately. For a compatible cover, search for model CHM3DCOVER. For the chime base and cover together, search for CHM3D.

The CHIMEBASE2 requires a 16-volt AC transformer (not included) for operation. Compatible transformers include Newhouse Hardware models #16TR or #3TRAN. This chime base is designed to be compatible with most Nutone models, including LA11BG, LA11WH, KA10, LA109, KB10, L12, L14, CD130, LA110, LA111, LA114, LA116, LA117, LA119, LA12, LA13, LA130, LA14, LA140, LA141, LA144, LA148, LA14WH, LA143, LA149, LA30SAVY, LA37, LA15, LA9, LB13, LB12, LB14, LD21, VG130, and VG190.

2. Informazzjoni dwar is-Sigurtà

  • Always disconnect power to the doorbell circuit at the main circuit breaker before attempting any installation, wiring, or maintenance. Failure to do so can result in electrical shock or serious injury.
  • Jekk m'intix ċert dwar xi parti tal-proċess tal-installazzjoni, ikkonsulta elettriċista kwalifikat.
  • Kun żgur li l-konnessjonijiet kollha tal-wajers huma sikuri u jikkonformaw mal-kodiċijiet elettriċi lokali.
  • This device is intended for low-voltage wired doorbell systems only. Do not connect to high-voltage linji.

3. Kontenut tal-Pakkett

  • 1 x Newhouse Hardware CHIMEBASE2 Doorbell Chime Mechanism (Base Only)

4. Setup u Installazzjoni

4.1 Qabel l-Installazzjoni

  1. Turn off power to your existing doorbell circuit at the main circuit breaker.
  2. Remove the cover from your old doorbell chime unit.
  3. Carefully disconnect the wires from the old chime unit, noting which wire was connected to which terminal (e.g., Front, Rear, Transformer). It is recommended to label the wires.
  4. Remove the old chime unit from the wall.

4.2 Mounting the Chime Base

  1. Position the CHIMEBASE2 in the desired location. The dimensions of the base are approximately 6.75 inches (L) x 4.75 inches (W) x 1.75 inches (D).
  2. Use appropriate screws (not included) to secure the chime base to the wall through the mounting holes. Ensure it is firmly attached.

4.3 Konnessjonijiet tal-Wiring

Refer to the internal wiring diagram on the chime mechanism and the image below for guidance.

Intern view of Newhouse Hardware CHIMEBASE2 doorbell chime mechanism with dimensions and wiring diagram.

Immaġni: Interna view of the CHIMEBASE2 showing the plungers, terminals, and a basic wiring diagram. Dimensions are indicated as 6.75 inches (L), 4.75 inches (W), and 1.75 inches (Overall Depth).

  1. Connect the wire from your 16V AC transformer to the terminal labeled TRANS.
  2. Connect the wire from your front doorbell button to the terminal labeled QUDDIEM.
  3. If you have a rear doorbell button, connect its wire to the terminal labeled Wara. If you only have one doorbell, you may leave the REAR terminal unconnected.
  4. Kun żgur li l-konnessjonijiet kollha huma stretti u sikuri.

4.4 Power On and Test

  1. Once all wiring is complete and secure, restore power to the doorbell circuit at the main circuit breaker.
  2. Press your front doorbell button. The chime should produce a 2-note melody.
  3. If you have a rear doorbell button, press it. The chime should produce a single-note melody.
  4. If the chime does not operate correctly, refer to the Troubleshooting section.

5. Istruzzjonijiet Operattivi

The Newhouse Hardware CHIMEBASE2 operates automatically when a doorbell button is pressed. It is designed to differentiate between front and rear door presses:

  • Bieb ta' Quddiem: Pressing the front doorbell button will activate a distinctive 2-note chime melody.
  • Rear Door: Pressing the rear doorbell button will activate a single-note chime melody.

This allows you to easily identify which door a visitor is at without needing to check.

6. Manutenzjoni

The CHIMEBASE2 is designed for minimal maintenance. However, if you experience issues with the chime mechanism, particularly sticking plungers, follow these steps:

  • Cleaning Sticking Plungers: Ensure power is disconnected at the circuit breaker. Place a few drops of non-flammable cleaning fluid (e.g., electrical contact cleaner) on the plungers. Work the plungers up and down gently until they move freely. DO NOT OIL PLUNGERS, as oil can attract dust and worsen the problem.
  • Tindif Ġenerali: Periodically wipe the exterior of the chime base with a soft, dry cloth to remove dust. Ensure power is off before cleaning.
Lura view of the Newhouse Hardware CHIMEBASE2 doorbell chime mechanism.

Immaġni: Wara view of the CHIMEBASE2, showing mounting points and overall structure.

7 Issolvi l-problemi

If your Newhouse Hardware CHIMEBASE2 is not functioning as expected, consult the following troubleshooting guide:

ProblemaKawża PossibbliSoluzzjoni
No chime sound
  • L-ebda enerġija fiċ-ċirkwit
  • Wajers maħlula jew mhux korretti
  • Transformer difettuż
  • Sticking plungers
  • Buttuna tal-qanpiena difettuża
  • Check circuit breaker; ensure power is on.
  • Verify all wiring connections (TRANS, FRONT, REAR) are secure.
  • Test transformer output with a multimeter (should be 16V AC). Replace if faulty.
  • Refer to Maintenance section for cleaning plungers.
  • Test doorbell button for continuity. Replace if faulty.
Weak or distorted chime sound
  • Underpowered transformer
  • Sticking plungers
  • Obstruction in chime mechanism
  • Ensure transformer is 16V/10VA or 16V/15VA. Upgrade if necessary.
  • Refer to Maintenance section for cleaning plungers.
  • Inspect the chime mechanism for any debris or obstructions.
Incorrect chime (e.g., 1-note for front door)
  • Incorrect wiring of front/rear doorbell buttons
  • Verify that the front doorbell wire is connected to the QUDDIEM terminal and the rear doorbell wire (if applicable) is connected to the Wara terminali.

8. Speċifikazzjonijiet

  • Mudell: CHIMEBASE2
  • Dimensjonijiet (L x W x H): 17.15 ċm x 12.07 ċm x 4.45 ċm (6.75 pulzieri x 4.75 pulzieri x 1.75 pulzieri)
  • Piż: Madwar 350 gramma
  • Kulur: Iswed
  • Rekwiżit ta' Enerġija: 16V AC Transformer (10VA or 15VA recommended, not included)
  • Chime Tones: 2-note (Front Door), 1-note (Rear Door)
  • Komponenti Inklużi: Doorbell Chime Base
  • Kompatibilità: Newhouse Hardware SKU CHM3D and most Nutone models (e.g., LA11BG, LA11WH, KA10, LA109, KB10, L12, L14, CD130, LA110, LA111, LA114, LA116, LA117, LA119, LA12, LA13, LA130, LA14, LA140, LA141, LA144, LA148, LA14WH, LA143, LA149, LA30SAVY, LA37, LA15, LA9, LB13, LB12, LB14, LD21, VG130, VG190)
  • Pajjiż ta' Oriġini: Iċ-Ċina

9. Garanzija u Appoġġ

Specific warranty information for the Newhouse Hardware CHIMEBASE2 is not provided in this manual. For details regarding warranty coverage, returns, or technical support, please refer to the product packaging, the retailer where the product was purchased, or visit the official Newhouse Hardware website. Please have your model number (CHIMEBASE2) and purchase information available when contacting support.

© 2024 Newhouse Hardware. All rights reserved.

Ask a question about this manual