1. Introduzzjoni
Thank you for choosing the Wellue B02 Automatic Upper Arm Blood Pressure Monitor. This device is designed for accurate and convenient measurement of your blood pressure and heart rate at home. It features a large, easy-to-read 3-color backlit LCD display, dual-user memory, and an adjustable cuff for comfortable use. Please read this manual thoroughly before using the device to ensure correct operation and to obtain the most accurate results.

Image 1.1: The Wellue B02 Blood Pressure Monitor with its accessories, including the cuff, AAA batteries, and USB cable.
2. Kontenut tal-Pakkett
Malli tiftaħ il-pakkett, jekk jogħġbok ivverifika li l-oġġetti kollha elenkati hawn taħt huma preżenti u mhux imħassra:
- 1 x Wellue B02 Blood Pressure Monitor
- 1 x Upper Arm Cuff (22-40 cm)
- 1 x USB Cable
- 4 x Batteriji AAA
- 1 x Manwal tal-Utent (dan id-dokument)
- 1 x Borża tal-Ħażna

Image 2.1: A visual representation of all items included in the Wellue B02 Blood Pressure Monitor package.
3. Prodott Aktarview
The Wellue B02 monitor is designed for ease of use, featuring a clear display and intuitive controls.
3.1 Komponenti tal-Apparat
- Display LCD: Shows blood pressure readings (SYS, DIA), pulse rate, date, time, and user indicator. Features a 3-color backlight for easy interpretation.
- Buttuna START/STOP: Powers the device on/off and initiates/stops a measurement.
- Buttuna SET: Used to adjust settings such as date, time, and user selection.
- Buttuna MEM: Jaċċessa r-rekords tal-kejl maħżuna.
- Port tal-Manku: Connects the air tube from the cuff to the monitor.
- Port tal-Enerġija USB: For optional power supply via USB cable.
- Kompartiment tal-batterija: Iżomm 4 batteriji AAA.

Immaġni 3.1: Fuqview of the Wellue B02 monitor highlighting its key features such as the LCD display, dual-user mode, and power options.
4. Setup
4.1 Provvista tal-Enerġija
The monitor can be powered by either AAA batteries or a USB cable.
- Installazzjoni tal-batterija: Open the battery compartment cover on the back of the device. Insert 4 AAA batteries, ensuring correct polarity (+/-). Close the cover securely.
- Qawwa tal-USB: Connect the provided USB cable to the USB port on the side of the monitor and to a compatible USB power source (e.g., wall adapter, computer USB port).
4.2 Twaħħil tal-Maniċċa
Insert the air tube connector from the cuff firmly into the air jack on the left side of the monitor.
4.3 Issettjar tad-Data u l-Ħin
Meta l-apparat ikun mitfi, agħfas u żomm il- SET button for 3 seconds to enter setting mode. Use the MEM button to adjust values and the SET button to confirm and move to the next setting (Year, Month, Day, Hour, Minute). Press BIDU/WAQQF biex toħroġ mill-modalità tas-settings.

Image 4.1: The Wellue B02 monitor illustrating its dual power supply options: battery power and USB cable connection.
5. Istruzzjonijiet Operattivi
5.1 Qabel il-Kejl
- Evita li tiekol, tixrob l-alkoħol, tpejjep, tagħmel eżerċizzju, u tgħawm għal 30 minuta qabel il-kejl.
- Istrieħ għal mill-inqas 5 minuti qabel ma tieħu kejl.
- Poġġi f'pożizzjoni komda b'dahrek appoġġjat u saqajk ċatti mal-art.
- Place your arm on a flat surface so the cuff is at heart level.
5.2 L-applikazzjoni tal-pulzieri
The adjustable cuff (22-40 cm) is designed to fit most adult upper arms.
- Slide your left arm through the cuff loop. The air tube should run down the inside of your arm.
- Position the cuff so the bottom edge is approximately 2-3 cm above your elbow joint.
- Wrap the cuff snugly around your upper arm. Ensure it is not too tight or too loose.
- The artery mark on the cuff should be aligned with your brachial artery (inner arm).
5.3 Teħid ta 'Kejl
- Agħfas il- BIDU/WAQQF button. The cuff will automatically inflate.
- Ibqa' kwiet u sieket waqt il-kejl.
- Once the measurement is complete, the cuff will deflate, and your systolic pressure (SYS), diastolic pressure (DIA), and pulse rate will be displayed on the LCD screen.
- The result will be automatically stored in the selected user's memory.
5.4 Dual User Mode
The device supports two users (User A and User B) with 120 memory sets each.
- To switch between User A and User B, press the SET button briefly when the device is off. The user icon will change.
- Measurements taken will be stored under the currently selected user profile.

Image 5.1: The Wellue B02 monitor demonstrating its dual-user capability, allowing two individuals to track their blood pressure readings separately.
5.5 Funzjoni tal-Memorja
Biex terġa 'view past measurements:
- When the device is off, press the MEM button. The screen will display the average of the last three readings for the current user.
- Agħfas MEM again to scroll through individual past readings, from most recent to oldest.
- Each record includes SYS, DIA, Pulse, date, and time.
6. Nifhmu r-Riżultati Tiegħek
The Wellue B02 monitor features a 3-color backlit LCD display to help you quickly interpret your blood pressure readings according to World Health Organization (WHO) guidelines.
- Dawl ta' wara aħdar: Indicates normal blood pressure.
- Dawl ta' wara Oranġjo: Indicates mild hypertension.
- Dawl ta' wara Aħmar: Indicates severe hypertension.
The monitor also includes an irregular heartbeat indicator and a movement error indicator to ensure measurement reliability.

Image 6.1: Explanation of the Wellue B02's 3-color backlit display, showing how green, orange, and red indicate different blood pressure ranges.

Image 6.2: The Wellue B02 monitor displaying its arrhythmia checking capability, which alerts users to irregular heartbeats.
7. Manutenzjoni u Kura
- Naddaf il-monitor u l-manku b'ċarruta ratba u niexfa. Tużax prodotti tat-tindif li joborxu jew tgħaddasx l-apparat fl-ilma.
- Store the device in the provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
- Neħħi l-batteriji jekk l-apparat ma jkunx se jintuża għal perjodu estiż biex tevita t-tnixxija.
- Do not attempt to disassemble or repair the monitor yourself. Contact customer support for assistance.
8 Issolvi l-problemi
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| L-apparat ma jixgħelx. | Batteries are depleted or incorrectly inserted; USB cable not connected. | Ibdel il-batteriji b'oħrajn ġodda, waqt li tiżgura l-polarità korretta. Iċċekkja l-konnessjoni tal-kejbil USB. |
| Cuff does not inflate or inflates incorrectly. | Cuff not properly connected; air leakage; cuff damaged. | Ensure cuff air tube is securely inserted into the monitor. Check cuff for any visible damage or leaks. |
| Qari mhux preċiż. | Pożizzjonament mhux korrett tal-manku; moviment waqt il-kejl; nuqqas ta' mistrieħ qabel il-kejl. | Refer to section 5.2 for correct cuff placement. Remain still and silent. Rest for 5 minutes before measuring. |
| Messaġġ ta' żball fuq il-wiri. | Measurement error (e.g., excessive movement, irregular heartbeat). | Repeat the measurement after resting for a few minutes, ensuring proper technique. If errors persist, consult a healthcare professional. |
9. Speċifikazzjonijiet
- Mudell: B02
- Metodu tal-Kejl: Oxxillometriku
- Medda ta' Kejl: Blood Pressure: 0-299 mmHg; Pulse: 40-199 beats/minute
- Eżattezza: Blood Pressure: ±3 mmHg (±0.4 kPa); Pulse: ±5% of reading
- Daqs tal-pulzier: 22-40 cm (Upper Arm)
- Memorja: 2 users x 120 sets with date and time
- Wiri: Large 3-color backlit LCD
- Sors tal-Enerġija: 4 x AAA batteries (included) or USB DC 5V
- Dimensjonijiet: Madwar 16.6 x 12 x 7.8 ċm
- Piż: Madwar 252 gramma (mingħajr batteriji)
- Kundizzjonijiet Operattivi: Temperature: 5°C to 40°C; Humidity: 15% to 85% RH
- Kundizzjonijiet tal-Ħżin: Temperature: -20°C to 55°C; Humidity: 10% to 93% RH
10. Informazzjoni Importanti dwar is-Sigurtà
TWISSIJIET:
- This device is intended for adult home use only. Consult your physician for interpretation of blood pressure readings. Self-diagnosis and treatment based on measurement results can be dangerous.
- Do not use this device on infants, children, or individuals unable to express consent.
- Do not use this device if you have a serious arrhythmia.
- Product packaging may contain information different from what is shown online. Always read labels, warnings, and instructions provided with the product before use.
- Żomm fejn ma jintlaħaqx mit-tfal. Partijiet żgħar jistgħu joħolqu periklu ta’ fgar.
11. Garanzija u Appoġġ
The Wellue B02 Automatic Upper Arm Blood Pressure Monitor comes with a garanzija ta 'sena mid-data tax-xiri.
For technical assistance, troubleshooting, or warranty claims, please contact our customer support. We offer 24-hour technical service biex niżguraw is-sodisfazzjon tiegħek.
Jekk jogħġbok żomm l-irċevuta tax-xiri tiegħek bħala prova tax-xiri għal skopijiet ta' garanzija.