The Hager EMN001 is a staircase time delay switch designed to control lighting circuits by automatically switching off the lights after a user-defined period. This device enhances energy efficiency and safety in common areas such as stairwells, corridors, and basements. It features an adjustable time delay and a compact design for DIN-rail mounting.
This manual provides essential information for the safe and correct installation, operation, and maintenance of your EMN001 time delay switch. Please read it thoroughly before installation and keep it for future reference.
Informazzjoni dwar is-Sigurtà
TWISSIJA: Electrical installation should only be performed by a qualified electrician in accordance with national wiring regulations and safety standards. Failure to follow these instructions can result in electric shock, fire, or serious injury.
- Dejjem skonnettja l-enerġija mis-circuit breaker prinċipali qabel ma tinstalla jew tagħmel manutenzjoni fuq l-apparat.
- Tiżgura l-provvista voltage jaqbel mal-volum nominali tal-apparattage (230V).
- Do not exceed the maximum load capacity of the switch (2300W for incandescent lamps, 16A AC1).
- Ipproteġi l-apparat mill-umdità u t-temperaturi estremi.
- This product is not battery-operated and does not contain hazardous materials requiring special disposal.
Prodott Overview
The Hager EMN001 is a compact, modular device designed for integration into electrical distribution boards. Key features include:
- Dewmien aġġustabbli tal-ħin minn 30-il sekonda sa 10 minuta.
- Two-position switch for permanent ON or timed operation.
- Pre-warning function for enhanced safety before lights switch off.
- DIN-rail mounting for easy installation.

Figura 1: Quddiem view of the Hager EMN001 Staircase Time Delay Switch, showing the time adjustment dial and the permanent/timed operation switch.
Istruzzjonijiet għall-installazzjoni
- Skonnettjar tal-Enerġija: Before starting any electrical work, ensure the main power supply to the circuit is completely disconnected at the consumer unit/circuit breaker. Verify with a voltagtester.
- Immuntar: Mount the EMN001 switch onto a standard DIN rail within an appropriate enclosure.
- Wiring: Irreferi għad-dijagramma tal-wajers hawn taħt għal konnessjonijiet korretti.
- Connect the Live (L) and Neutral (N) supply wires to the corresponding terminals on the switch.
- Connect the switched Live output to the lighting circuit.
- Connect the push-button input (if applicable for staircase lighting) to the designated terminal.
- Kun żgur li t-terminals kollha tal-kamin huma ssikkati sew biex tevita li l-konnessjonijiet maħlula.
- Speċifikazzjonijiet tal-kejbil: Use flexible cables with a cross-section of 1 to 6 mm² or solid cables with a cross-section of 1.5 to 10 mm².
- Restawr tal-Enerġija: Ladarba l-konnessjonijiet kollha jkunu siguri u vverifikati, erġa' daħħal l-enerġija fiċ-ċirkwit.

Figura 2: Wiring diagram for the Hager EMN001 Staircase Time Delay Switch. Shows connections for Live (L), Neutral (N), push-buttons, and lighting loads.
Istruzzjonijiet Operattivi
Aġġustament tad-Dewmien tal-Ħin
The time delay can be adjusted using the rotary dial on the front of the device. The range is from 30 seconds to 10 minutes. Rotate the dial clockwise to increase the delay time and counter-clockwise to decrease it. Set the desired time according to your application requirements.
Għażla tal-Modalità ta' Operazzjoni
The EMN001 features a two-position switch for selecting the operation mode:
- Timed Mode (Timer Symbol): In this mode, the lights will switch on when a connected push-button is pressed and will automatically switch off after the preset time delay has elapsed. This is the standard mode for staircase lighting.
- Permanent ON Mode (Light Bulb Symbol): In this mode, the lights will remain continuously on, bypassing the time delay function. This is useful for extended periods of illumination, such as during cleaning or maintenance.
Pre-warning Function
For enhanced safety, the EMN001 includes a pre-warning function. Before the lights switch off completely, they will briefly dim or flash to alert users that the timed period is about to end, allowing them to reactivate the lights if needed.
Manutenzjoni
The Hager EMN001 time delay switch is designed for maintenance-free operation. However, periodic checks are recommended:
- Spezzjoni Viżwali: Periodically inspect the device for any signs of damage, discoloration, or loose connections.
- Tindif: If necessary, gently clean the exterior of the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Kontroll Funzjonali: Occasionally test the time delay function and the permanent ON mode to ensure proper operation.
If any issues are detected, disconnect power immediately and consult a qualified electrician.
Issolvi l-problemi
If you experience problems with your Hager EMN001 switch, refer to the following table:
| Problema | Kawża Possibbli | Soluzzjoni |
|---|---|---|
| Id-dwal ma jixegħlux. | No power supply, faulty wiring, faulty push-button, or faulty lamp. | Check circuit breaker. Verify wiring connections. Test push-button and lamp. |
| Lights stay on permanently in timed mode. | Switch set to permanent ON mode, or a stuck push-button. | Ensure the mode switch is set to the timed (timer symbol) position. Check push-buttons for sticking. |
| Lights turn off too quickly or too slowly. | Incorrect time delay setting. | Adjust the time delay dial to the desired duration. |
| Pre-warning function not working. | Ħsara fl-apparat. | Consult a qualified electrician for inspection or replacement. |
If the problem persists after attempting these solutions, contact a qualified electrician or Hager customer support.
Speċifikazzjonijiet Tekniċi
| Parametru | Valur |
|---|---|
| Mudell | EMN001 |
| Vol Operattiv Ratedtage | 230 V AC |
| Frekwenza | 50/60 Hz |
| Max. Power (Incandescent Lamps) | 2300 W |
| Kurrent Nominali (AC1) | 16 A |
| Time Delay Adjustment Range | 30 sekonda sa 10 minuta |
| Tip ta' Konnessjoni | Terminali bil-kamin |
| Flexible Cable Cross-section | 1 - 6 mm² |
| Solid Cable Cross-section | 1.5 - 10 mm² |
| Metodu ta 'Immuntar | Ferrovija DIN |
| Temperatura operattiva | -10 °C sa +55 °C |
| Temperatura tal-Ħażna | -20 °C sa +60 °C |
| Klassifikazzjoni tal-Protezzjoni IP | IP20 |
| Dimensjonijiet (Tbaħħir) | 8 x 6 x 4 ċm |
| Piż tal-oġġett | 150 gramma |
| Batteriji Meħtieġa | Nru |
| Pajjiż ta' Oriġini | Franza |
Garanzija u Appoġġ
Hager products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided with your purchase or visit the official Hager website. In case of technical issues or questions not covered in this manual, please contact your local Hager distributor or customer support for assistance.
Għal aktar informazzjoni, tista' żżur il- Hager brand page on Amazon.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.