AUTOOL LM120

Manwal tal-Utent tal-Gauge tal-Manifold Diġitali AUTOOL LM120

Mudell: LM120

1. Introduzzjoni

The AUTOOL LM120 Digital Manifold Gauge is an intelligent electronic instrument designed to assist in the installation, testing, and maintenance of refrigeration equipment. This includes systems such as air conditioners, refrigerators, and cold storage units. It provides precise measurements for pressure, temperature, and vacuum, along with advanced diagnostic capabilities.

AUTOOL LM120 Digital Manifold Gauge with hoses connected to a car's AC system

Image 1.1: AUTOOL LM120 Digital Manifold Gauge in use, connected to an automotive air conditioning system.

2. Informazzjoni dwar is-Sigurtà

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in injury or damage to the equipment.

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working with refrigeration systems and refrigerants.
  • Ensure adequate ventilation in the work area to prevent the accumulation of refrigerant gases.
  • Do not expose the device to extreme temperatures, direct sunlight, or corrosive environments.
  • Handle refrigerant hoses and connections with care to prevent leaks and accidental discharge.
  • Refer to local regulations and industry standards for the safe handling, recovery, and disposal of refrigerants.
  • Do not attempt to repair or modify the device. Contact qualified personnel for service.

3. Prodott Aktarview u Komponenti

The LM120 Digital Manifold Gauge features a robust design with an intuitive interface. Familiarize yourself with the components shown below.

Diagram of AUTOOL LM120 Digital Manifold Gauge with numbered components

Image 3.1: Detailed diagram of the LM120 Digital Manifold Gauge components.

  1. Ganċ
  2. ClampSokit tas-Sonda tat-Temperatura -on
  3. Display LCD
  4. Buttuna tal-Funzjoni
  5. Buttuna Mexxi/Stop
  6. Buttuna Żero
  7. Buttuni tal-Għażla tat-Tip ta' Refriġerant R+/R-
  8. Buttuna tad-Dimming
  9. Buttuna tal-Unità
  10. Buttuna ° C / ° F
  11. Buttuna tal-Qawwa
  12. Valv ta 'Pressjoni Baxxa
  13. Tieqa ta' Osservazzjoni tar-Refriġerant
  14. Valv ta 'Pressjoni Għolja
  15. Dħul ta' Pressjoni Baxxa ta' 1/4 pulzier
  16. Valv ta' Ħelsien
  17. Dħul ta' Pressjoni Għolja ta' 1/4 pulzier
  18. Dħul tar-Refriġerant / Dħul tal-Pompa tal-Vakwu

4. Setup

Qabel l-ewwel użu, kun żgur li l-apparat ikun lest għall-użu.

4.1 Tixgħel Inizjali

  • Agħfas u żomm il- Buttuna tal-Qawwa (11) to turn on the device.
  • The LCD Display (3) will illuminate and show the initial readings.

4.2 Konnessjoni tal-Pajpijiet

Connect the appropriate refrigeration hoses to the inlets on the manifold gauge.

  • Connect the low-pressure hose to the Dħul ta' Pressjoni Baxxa ta' 1/4 pulzier (15).
  • Qabbad il-pajp ta 'pressjoni għolja mal- Dħul ta' Pressjoni Għolja ta' 1/4 pulzier (17).
  • Connect the service hose (for vacuum pump or refrigerant tank) to the Dħul tar-Refriġerant / Dħul tal-Pompa tal-Vakwu (18).
  • Kun żgur li l-konnessjonijiet kollha huma ssikkati biex tevita tnixxijiet.

4.3 Connecting Temperature Probes (Optional)

For dual temperature measurement, connect compatible clamp-on temperature probes (not included) to the ClampSokit tas-Sonda tat-Temperatura -on (2).

5. Istruzzjonijiet Operattivi

This section details the various functions and how to operate the AUTOOL LM120.

5.1 Display Overview

The large LCD provides clear, real-time data for pressure, temperature, and other parameters.

Close-up of the AUTOOL LM120 Digital Manifold Gauge's smart digital display showing pressure and temperature readings

Image 5.1: The smart digital display provides clear readings for various parameters.

5.2 Għażla ta' Unità

To change pressure or temperature units:

  • Agħfas il- Buttuna tal-Unità (9) to cycle through available pressure units (e.g., Kpa, Psi, Bar).
  • Agħfas il- Buttuna ° C / ° F (10) to switch between Celsius and Fahrenheit temperature displays.

5.3 Refrigerant Type Setting

The device has a built-in database of 89 refrigerants. Select the correct refrigerant type for accurate calculations.

AUTOOL LM120 Digital Manifold Gauge showing refrigerant type R11 on its display

Image 5.2: Setting the refrigerant type on the LM120 display.

  • Uża l- Buttuni tal-Għażla tat-Tip ta' Refriġerant R+/R- (7) to scroll through the available refrigerant types.
  • Ikkonferma l-għażla tiegħek.

5.4 Kejl tal-Pressjoni

The LM120 measures both high and low pressures simultaneously.

  • Ensure hoses are correctly connected to the high and low-pressure ports of the system.
  • The display will show the current high and low pressure readings.

5.5 Kejl tat-Temperatura

With optional clamp-on temperature probes, the device can measure dual temperatures.

AUTOOL LM120 Digital Manifold Gauge displaying T1 Sensor and T2 Sensor temperatures

Image 5.3: High/Low pressure temperature test display.

  • Attach the temperature probes to the desired measurement points (e.g., suction line, liquid line).
  • The display will show T1 and T2 temperature readings.

5.6 Evaporation Pressure & Temperature Test

This function measures the maximum pressure when the refrigerant changes from liquid to gas and the lowest temperature when the liquid becomes gaseous.

AUTOOL LM120 Digital Manifold Gauge displaying evaporation pressure and temperature test results

Image 5.4: Evaporation pressure and temperature test results on the display.

5.7 Condensing Pressure & Temperature Test

This function measures the minimum pressure when the refrigerant changes from gas to liquid and the maximum temperature when the gas changes to liquid.

AUTOOL LM120 Digital Manifold Gauge displaying condensing pressure and temperature test results

Image 5.5: Condensing pressure and temperature test results on the display.

5.8 Pressure Leakage Test

The device can perform a pressure leakage test, recording leak time and speed.

AUTOOL LM120 Digital Manifold Gauge displaying pressure leakage test results with time and pressure values

Image 5.6: Pressure leakage test in progress, showing initial and current pressure values over time.

  • Connect the gauge to the system to be tested.
  • Agħfas il- Buttuna tal-Funzjoni (4) to navigate to the leakage test mode.
  • Follow the on-screen prompts to start and monitor the test. The device calculates the pressure difference between the initial and second test pressures to determine if refrigerant is leaking.

5.9 Kejl tal-vakwu

The LM120 can measure the percentage of vacuum achieved in a system.

  • Connect the vacuum pump to the Dħul tar-Refriġerant / Dħul tal-Pompa tal-Vakwu (18).
  • Activate the vacuum pump and monitor the vacuum percentage fuq il-wiri.

5.10 Kalkolu tas-Supersħana u s-Subtkessiħ

Leveraging its integrated 89-type refrigerant database, the LM120 can automatically calculate superheat and subcooling temperatures.

Table showing 89 types of refrigerant data built into the LM120 Digital Manifold Gauge

Image 5.7: Built-in database of 89 refrigerant types for accurate calculations.

  • Ensure the correct refrigerant type is selected (refer to Section 5.3).
  • With pressure and temperature probes connected, the device will display calculated superheat and subcooling values.

6. Manutenzjoni

Proper maintenance ensures the longevity and accuracy of your LM120 Digital Manifold Gauge.

  • Tindif: Imsaħ l-apparat b'ċarruta ratba u niexfa. Tużax prodotti tat-tindif jew solventi li joborxu.
  • Ħażna: Store the gauge in its original case or a protective container in a cool, dry place away from direct sunlight and extreme temperatures.
  • Spezzjoni tal-pajp: Regularly inspect refrigerant hoses for cracks, wear, or damage. Replace damaged hoses immediately.
  • Kontroll tal-Konnessjoni: Ensure all connections and valves are clean and free of debris.

7 Issolvi l-problemi

If you encounter issues with your LM120, refer to the following common problems and solutions.

ProblemaKawża PossibbliSoluzzjoni
L-apparat ma jixgħelxLow or depleted internal battery; power button not pressed correctly.Ensure the device is charged or has sufficient power. Press and hold the Power Button firmly.
Qari mhux preċiż tal-pressjoni/temperaturaIncorrect refrigerant selected; loose hose connections; faulty probes; sensor calibration needed.Verify the correct refrigerant type. Check all hose connections for tightness. Ensure temperature probes are clean and properly connected. Perform a zero calibration if available (using Zero Button).
Il-wiri huwa baxx jew ma jistax jinqaraBacklight off; low battery.Press the Dimming Button (8) to adjust backlight. Ensure the device is charged.
Leakage test shows false positive/negativeImproper connection; external temperature fluctuations; insufficient test duration.Ensure all connections are absolutely leak-free. Conduct the test in a stable environment. Allow sufficient time for the test to complete.

8. Speċifikazzjonijiet

Detailed technical specifications for the AUTOOL LM120 Digital Manifold Gauge.

KaratteristikaSpeċifikazzjoni
ManifatturAUTOOL
Numru tal-MudellLM120
MaterjalHigh-strength Engineering Plastic
Firxa tat-Test tal-Pressjoni0 Kpa – 6000 Kpa
Riżoluzzjoni tat-Test tal-Pressjoni1 Kpa
Preċiżjoni tat-Test tal-Pressjoni+/- 0.5 %(FS) + 5dgt
Limitu ta' Tagħbija żejda tal-Pressjoni10000 Kpa (10 Mpa; 100 bar)
Number of Refrigerants in Database89-il tip
Standard Interface1/4 pulzier
Dimensjonijiet (L x W x H)20.32 x 7.62 x 12.7 ċm (8 x 3 x 5 pulzieri)
Piż59.53 g (2.1 Uqija)
Komponenti Inklużi1 set of LM120 Digital Refrigeration Manifold Gauge
Batteriji MeħtieġaNo (implies internal rechargeable or power source)
UPC733810026709, 733810026198

9. Garanzija u Appoġġ

AUTOOL is committed to providing high-quality products and customer satisfaction.

  • Garanzija ta 'tliet snin: For damage caused by non-human factors, AUTOOL promises to resend parts free of charge within 3 years from the date of purchase.
  • Permanent Maintenance: The product is covered by permanent maintenance support.
  • Appoġġ għall-Klijent: For any inquiries, technical assistance, or warranty claims, please contact AUTOOL customer support. You can expect a response within 24 hours.

© 2024 AUTOOL. All rights reserved.