This manual provides essential information for the safe and efficient installation, operation, and maintenance of the MEAN WELL RD-65A Dual Output Switching Power Supply. Please read this manual thoroughly before using the product and retain it for future reference.

Figure 0: MEAN WELL RD-65A Dual Output Switching Power Supply.
The RD-65A is a 66W dual output power supply designed for various electronic applications, providing stable 5V and 12V DC outputs.
Karatteristiċi tal-Prodott
- Input universali AC / Firxa sħiħa
- Protezzjonijiet: Short circuit / Overload / Over voltage
- Tkessiħ b'konvezzjoni ta' arja ħielsa
- Indikatur LED għall-enerġija mixgħul
- 100% tagħbija sħiħa burn-in test
- Kollha jużaw kapaċitaturi elettrolitiċi ta 'ħajja twila ta' 105 ° C
- Jiflaħ dħul ta 'żieda ta' 300VAC għal 5 sekondi
- Temperatura operattiva għolja sa 70 ° C
- Jiflaħ it-test tal-vibrazzjoni 5G
- Effiċjenza għolja, ħajja twila u affidabilità għolja
- 3 snin ta 'garanzija
Speċifikazzjonijiet
Output Characteristics (RD-65A)
| Numru tal-Output | CH1 | CH2 |
|---|---|---|
| DC Voltage | 5V | 12V |
| Kurrent Rated | 6A | 3A |
| Medda Kurrenti | 0.3 - 6A | 0.2 - 3A |
| Qawwa Rated | 66W | |
| Ripple & Storbju (mass.) | 120mVp-p | 120mVp-p |
| Voltage ADJ. Range | CH1: 4.75 - 5.5V | |
| Voltage Tolleranza | ±2.0% | ±6.0% |
| Regolament tal-Linja | ±0.5% | ±1.0% |
| Regolament tat-Tagħbija | ±1.0% | ±3.0% |
| Setup, Ħin ta' Tlugħ | 500ms, 20ms/230VAC; 1200ms, 20ms/115VAC b'tagħbija sħiħa | |
| Hold Up Time (typ.) | 80ms/230VAC; 14ms/115VAC b'tagħbija sħiħa | |
Karatteristiċi tal-Input
| Karatteristiku | Valur |
|---|---|
| Voltage Firxa | 88 ~ 264VAC; 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) |
| Medda ta' Frekwenzi | 47 ~ 63Hz |
| Effiċjenza (tip.) | 78% |
| Kurrent AC (tip.) | 2A/115VAC; 1.2A/230VAC |
| Kurrent Inrush (tip.) | START KIESA 40A/230VAC |
| Tnixxija Kurrent | <2mA / 240VAC |
Protezzjoni
| Tip | Deskrizzjoni |
|---|---|
| Tagħbija żejda | 105 ~ 160% rated output power. Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
| Fuq Voltage | CH1: 5.75 ~ 6.75V. Protection type: Hiccup mode, recovers automatically after fault condition is removed. |
Environmental & Safety
| Karatteristiku | Valur |
|---|---|
| Temp tax-Xogħol. | -25 ~ +70°C (Refer to "Derating Curve") |
| Umdità tax-Xogħol | 20 ~ 90% RH li ma jikkondensax |
| Temperatura tal-Ħażna, Umdità | -40 ~ +85°C, 10 ~ 95% RH |
| Temp. Koeffiċjent | ±0.03%/°C (0 ~ 50°C) on 5V output |
| Vibrazzjoni | 10 ~ 500Hz, 5G 10min./1cycle, perjodu għal 60min. kull wieħed tul X, Y, Z assi |
| Standards tas-Sigurtà | UL60950-1, TUV EN60950-1 approved |
| Jiflaħ Voltage | I/P-O/P:3KVAC; I/P-FG:1.5KVAC; O/P-FG:0.5KVAC |
| Reżistenza għall-Iżolament | I/P-O/P, I/P-FG, O/P-FG: >100M Ohms / 500VDC / 25°C / 70% RH |
| EMI Emission | Konformità ma' EN55022 (CISPR22) Klassi B, EN61000-3-2,-3 |
| EMI Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A |
| MTBF | Minimu ta' 265.9Khrs MIL-HDBK-217F (25°C) |
Dimensjonijiet Fiżiċi
- Dimensjonijiet tal-oġġett L x W x H: 5.08 x 3.86 x 1.5 pulzieri (129 x 98 x 38 mm)
- Piż tal-oġġett: 5 Grams (Note: This weight seems unusually low for a power supply of this type. Please verify with product packaging.)
- Ippakkjar: 0.7kg; 20pcs/14.7kg/1.72CUFT
Setup u Installazzjoni
Installazzjoni Mekkanika
The power supply should be mounted in a location that allows for adequate air circulation for cooling. Refer to the mechanical drawing for dimensions and mounting hole positions.

Figure 1: Mechanical dimensions and mounting points for the RD-65A power supply. Dimensions are in millimeters.
Ensure the power supply is securely mounted to prevent movement or vibration during operation.
Konnessjonijiet tal-Wiring
Connect the input and output wires according to the terminal pin assignments. Ensure all connections are secure and properly insulated to prevent short circuits.
| Pin numru | Assenjazzjoni | Pin numru | Assenjazzjoni |
|---|---|---|---|
| 1 | AC / L | 4,5 | ĦRUĠ DC COM |
| 2 | AC / N | 6 | ĦRUĠ DC +V2 |
| 3 | FG | 7 | ĦRUĠ DC +V1 |
Konnessjonijiet tad-dħul:
- Connect the AC Live wire to Pin 1 (AC/L).
- Connect the AC Neutral wire to Pin 2 (AC/N).
- Connect the Frame Ground (FG) to Pin 3. This connection is crucial for safety.
Konnessjonijiet tal-Ħruġ:
- Connect the common ground for DC outputs to Pins 4 and 5 (DC OUTPUT COM).
- Connect the +12V DC output to Pin 6 (DC OUTPUT +V2).
- Connect the +5V DC output to Pin 7 (DC OUTPUT +V1).
Note: Always ensure the power supply is disconnected from the AC mains before making any wiring connections.
Istruzzjonijiet Operattivi
Once the power supply is correctly installed and wired, it is ready for operation. The RD-65A is designed for continuous operation within its specified limits.
Qawwa mixgħul/mitfi
Connect the AC input to a suitable power source. The LED indicator on the unit will illuminate, indicating that the power supply is active and providing output voltage.
To turn off the power supply, disconnect the AC input from the power source.
Blokk Dijagramma Overview

Figure 2: Internal block diagram of the RD-65A power supply.
The block diagram illustrates the internal functional stages:
- EMI Filter: Reduces electromagnetic interference from the AC input.
- Rectifiers & Filter: Converts AC input to DC voltage.
- Power Switching: High-frequency switching to regulate the output voltage.
- Kontroll: Monitors and regulates the output, including Over Load Protection (O.L.P.) and Over Voltage Protection (O.V.P.) circuits.
- Output Rectifiers & Filter: Converts the switched voltage back to stable DC outputs (+V1, +V2, COM).
The power supply is designed to operate efficiently and reliably within its specified load and environmental conditions.
Kurva tad-Derating
The derating curve indicates the maximum permissible output load as a function of ambient temperature and input voltage. Operating the power supply within these curves ensures optimal performance and longevity.

Figure 3: Output Derating Curve vs. Ambient Temperature and Input Voltage.
- Ambient Temperature Derating: As the ambient temperature increases, the maximum allowable output load decreases. Ensure adequate ventilation to maintain the temperature within safe operating limits.
- Input Voltage Derating: The power supply can deliver full rated power across its specified input voltage range. However, for prolonged operation at the lower end of the input voltage range, it is advisable to refer to the input voltage derating kurva.
Exceeding these limits can lead to reduced lifespan or damage to the unit.
Prekawzjonijiet tas-Sigurtà
To ensure safe operation and prevent damage to the power supply or connected equipment, observe the following precautions:
- Sigurtà Elettrika: Always disconnect the AC input power before performing any installation, wiring, or maintenance. Ensure proper grounding (FG) is established.
- Ventilazzjoni: Do not obstruct the ventilation holes. Ensure sufficient airflow around the unit to prevent overheating.
- Ambjent: Operate the power supply within the specified temperature and humidity ranges. Avoid exposure to moisture, dust, and corrosive substances.
- Kapaċità tat-Tagħbija: Do not exceed the rated output power or current for each channel. Overloading can trigger protection mechanisms or cause damage.
- Karatteristiċi ta' Protezzjoni: The unit includes short circuit, overload, and over voltage protections. While these protect the unit, continuous triggering of these protections should be avoided. Investigate and resolve the cause of any protection activation.
- Persunal kwalifikat: L-installazzjoni u s-servizz għandhom jitwettqu biss minn persunal kwalifikat.
Issolvi l-problemi
If the power supply is not functioning as expected, consider the following common issues and solutions:
- Nru Vol. Outputtage / LED Off:
- Check if the AC input power is connected and active.
- Ivverifika l-input voltage huwa fil-medda speċifikata (88-264VAC).
- Inspect input fuses (if external).
- Ħruġ Voltage Fluctuating or Low:
- Ensure the load connected does not exceed the rated output current or power.
- Check for loose wiring connections at the output terminals.
- Verify the ambient temperature is within the operating range and ventilation is adequate.
- Unit Shuts Down:
- This may indicate activation of overload or over voltage protection. Disconnect the load and re-apply power. If it operates normally, the issue is with the load.
- Check for short circuits in the output wiring or connected device.
- Ensure the unit is not overheating due to insufficient ventilation or high ambient temperature.
If the problem persists after checking these points, contact qualified service personnel or MEAN WELL support.
Manutenzjoni
The MEAN WELL RD-65A power supply is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure its longevity:
- Tindif: Periodically clean the exterior of the unit to prevent dust accumulation, especially around ventilation openings. Use a soft, dry cloth. Do not use liquid cleaners.
- Kontrolli tal-Konnessjoni: Occasionally inspect all wiring connections for tightness and signs of corrosion or damage.
- Monitoraġġ Ambjentali: Kun żgur li l-ambjent operattiv jibqa' fil-limiti speċifikati tat-temperatura u l-umdità.
No user-serviceable parts are inside. Do not attempt to open or repair the unit yourself. Refer all servicing to qualified personnel.
Garanzija u Appoġġ
The MEAN WELL RD-65A Dual Output Switching Power Supply is generally covered by a garanzija ta 'sena from the date of purchase, ensuring high quality and reliability.
For technical support, warranty claims, or service inquiries, please contact your authorized MEAN WELL distributor or reseller. Provide your product model number (RD-65A) and purchase details when seeking assistance.