The Sloan Regal 180 Exposed Manual Urinal Flushometer is a robust and reliable plumbing solution designed for commercial and industrial restroom applications. This model features a 3.5 Gallons Per Flush (GPF) valve, ensuring efficient water usage while maintaining effective flushing performance. Its polished chrome finish provides a clean and professional aesthetic.

  • Accurate Flush Volume: Designed with a non-hold-open handle and no external volume adjustment, promoting water conservation.
  • Vacuum Breaker Flush Connection: Prevents backflow, ensuring hygienic operation.
  • Kostruzzjoni Durabbli: Made with high copper, low zinc brass castings for dezincification resistance, suitable for commercial environments.
  • Installazzjoni faċli: Includes a sweat solder adapter and cover tube for a secure connection.
  • Control Stop Plug: Facilitates easy maintenance and water flow adjustment.
  • Konformi mal-ADA: Features an ADA-compliant metal oscillating non-hold-open handle for accessibility.
Sloan Regal 180 Exposed Manual Urinal Flushometer

Image 1: The Sloan Regal 180 Exposed Manual Urinal Flushometer in polished chrome finish.

2. Setup u Installazzjoni

Installation of the Sloan Regal 180 Flushometer should be performed by a qualified plumber in accordance with local plumbing codes. Ensure all water supply lines are shut off before beginning installation.

  1. Ipprepara l-Provvista tal-Ilma: Ensure the 1" I.P.S. screwdriver Bak-Chek angle stop is properly installed and secured to the water supply line.
  2. Mount the Flushometer: Attach the flushometer body to the angle stop. The cast wall flange with a set screw ensures a stable and secure installation on the wall.
  3. Connect to Urinal: Utilize the sweat solder adapter and cover tube to connect the flushometer to the urinal's top spud. Ensure all connections are tight and leak-free.
  4. Test għal Tnixxijiet: Iftaħ il-provvista prinċipali tal-ilma bil-mod u ċċekkja l-konnessjonijiet kollha għal xi sinjali ta’ tnixxija.
  5. Aġġusta l-Fluss tal-Ilma: Use the control stop plug to fine-tune the water flow as needed.
Sloan Regal 180 Flushometer installed on a urinal

Image 2: Sloan Regal 180 Flushometer correctly installed on a urinal.

Sloan Regal 180 Flushometer installed on a urinal from a side view

Immaġni 3: Ġenb view of the Sloan Regal 180 Flushometer installation.

3. Istruzzjonijiet Operattivi

The Sloan Regal 180 Flushometer is designed for simple and consistent operation.

  1. Initiate Flush: Firmly push or pull the non-hold-open handle. The handle will return to its original position automatically after initiating the flush cycle.
  2. Fluss tal-Ilma: Water will flow through the urinal for a predetermined duration, delivering 3.5 gallons per flush.

Video 1: Official Sloan Regal Flushometer demonstration, showing the flushing action and product features.

4. Manutenzjoni

Regular maintenance ensures optimal performance and longevity of your Sloan Regal 180 Flushometer.

  • Tindif: Clean the exterior chrome finish with a mild, non-abrasive cleaner and a soft cloth. Avoid harsh chemicals that can damage the finish.
  • Spezzjoni tad-dijaframma: Periodically inspect the diaphragm assembly for wear or damage. A worn diaphragm can lead to continuous flushing or insufficient water flow. Replacement diaphragms are available from Sloan.
  • Inlet Valve Check: If water flow is weak or inconsistent, check the inlet valve for any obstructions or debris. The control stop plug can be used to temporarily shut off water for inspection.
Internal diaphragm component of a Sloan flushometer

Immaġni 4: Eż.ample of a diaphragm component, crucial for flushometer function.

5 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Fwawar kontinwuWorn or damaged diaphragm; debris in valve.Replace diaphragm; clean valve components.
Weak or incomplete flushInsufficient water pressure; partially closed control stop; clogged inlet.Check building water pressure; fully open control stop; clean inlet.
Tnixxija mill-konnessjonijietLoose connections; worn gaskets.Tighten connections; replace gaskets.

6. Speċifikazzjonijiet

  • Materjal: Ram
  • Tlestija ta' barra: Chrome illustrat
  • Dimensjonijiet tal-oġġett (L x W x H): 9.75 x 9.13 x 4.38 pulzieri
  • Daqs tal-Konnessjoni tad-Dħul: 1 Pulzier
  • Tip ta' Konnessjoni tad-Dħul: Għaraq
  • Tip ta' Konnessjoni tal-Ħut: Fixture Top Spud
  • Daqs tal-Konnessjoni tal-Ħruġ: 1.25 Pulzier
  • Pressjoni Operattiva Massima: 80 Lira għal kull Pulzier kwadru
  • Tip ta 'valv: Valv tad-dijaframma
  • Daqs: 3.5 GPF (Galluni Għal Kull Tlaħliħ)
  • Speċifikazzjoni sodisfatta: Konformi mal-ADA
  • Numru tal-Mudell: 3082453
  • UPC: 671254123472, 735090020934

7. Garanzija u Appoġġ

The Sloan Regal 180 Exposed Manual Urinal Flushometer comes with a Garanzija Limitata ta' Sena from the manufacturer, Sloan Valve Co. For detailed warranty information, technical support, or to purchase replacement parts, please visit the official Sloan websit jew ikkuntattja lid-dipartiment tas-servizz tal-konsumatur tagħhom.

Tista 'wkoll iżżur il- Sloan Store on Amazon għal aktar prodotti u informazzjoni.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.